GB 12476.5-2013   Electrical Apparatus for Use in the Presence of Combustible Dust - Part 5: Protection by Enclosures “tD” (English Version)
Standard No.: GB 12476.5-2013 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 6000 words Translation Price(USD):160.0 remind me the price change

Email:

Implemented on:2014-11-14 Delivery: via email in 1 business day

→ → →

,2022-5-1,2014-11-14,14113818220556537C9649749145F
Standard No.: GB 12476.5-2013
English Name: Electrical Apparatus for Use in the Presence of Combustible Dust - Part 5: Protection by Enclosures “tD”
Chinese Name: 可燃性粉尘环境用电气设备 第5部分:外壳保护型tD
Chinese Classification: K35    Explosion-proof electric apparatus
Professional Classification: GB    National Standard
ICS Classification: 29.260.20 29.260.20    Electrical apparatus for explosive atmospheres 29.260.20
Source Content Issued by: AQSIQ;SAC
Issued on: 2013-12-17
Implemented on: 2014-11-14
Status: superseded
Superseded by:GB/T 3836.31-2021 Explosive atmospheres—Part 31:Equipment dust ignition protection by enclosure “t”
Superseded on:2022-5-1
Target Language: English
File Format: PDF
Word Count: 6000 words
Translation Price(USD): 160.0
Delivery: via email in 1 business day
1 Scope This part of GB 12476 is applicable to electrical apparatus protected by enclosures and surface temperature limitation for use in areas where combustible dust may be present in quantities which could lead to a fire or explosion hazard. It specifies requirements for design, construction and testing of electrical apparatus. This part supplements the general requirements in GB 12476.1. Note: GB 12476.2 gives guidance on the selection and installation of the apparatus. Apparatus within the scope of this part may also be subjected to additional requirements in other standards – for example, GB 3836.1. The ignition protection is based on the limitation of the maximum surface temperature of the enclosure and on other surfaces which could be in contact with dust and on the restriction of dust ingress into the enclosure by the use of "dust-tight" or "dust-protected" enclosures. The application of electrical apparatus in atmospheres which may contain explosive gas as well as combustible dust, whether simultaneously or separately, requires additional protective measures. Where the apparatus must meet other environmental conditions, for example, protection against ingress of water and resistance to corrosion, additional methods of protection may be necessary. The method used should not adversely affect the integrity of the enclosure. This part does not apply to dusts of explosives which do not require atmospheric oxygen for combustion, or to pyrophoric substances. This part is not applicable to electrical apparatus intended for use in underground parts of mines as well as those parts of surface installations of such mines endangered by firedamp and/or combustible dust. This part does not take account of any risk due to an emission of flammable or toxic gas from the dust. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB 4208-2008 Degrees of protection provided by enclosure(IP code) (IEC 60529: 2001, IDT) IEC 61241-0: 2013 Electrical apparatus for use in the presence of combustible dust Part 0: General requirements) 3 Terms and definitions For the purposes of this document, the terms and definitions given in IEC 61241-0, as well as the following definitions, apply. 3.1 dust ignition protection type “tD” all relevant measures applied to electrical apparatus protected by an enclosure to avoid ignition of a dust layer or cloud
Foreword I Introduction III 1 Scope 2 Normative references 3 Terms and definitions 4 Construction 5 Practice A and practice B 6 Supplementary requirements for electrical apparatus protected by enclosures for practice A for use in zones 20, 21 and 7 Supplementary requirements for electrical apparatus protected by enclosures for practice B for use in zone 20 or 8 Verification and tests 9 Marking Bibliography
Referred in GB 12476.5-2013:
*GB 4208-2008 Degrees of Protection Provided By Enclosure (IP Code)
GB 12476.5-2013 is referred in:
* GB 31094-2014 Safety Rules for the Construction and Installation of Lifts for Explosive Atmospheres
*GB/T 3836.15-2017 Explosive atmospheres—Part 15: Electrical installations design, selection and erection
*SH/T 3038-2017 Code for Electric Power Design in Petrochemical Plants
*CNCA-C23-01-2019 Implementation rules for compulsory product certification - Explosion-proof Electrical Products
*GB/T 36035-2018 Pharmaceutical machinery—General requirements for electrical safety
*GB/T 36035-2018/XG1-2022 Pharmaceutical machinery-General requirements for electrical safety, includes Amendment 1
Code of China
Standard
GB 12476.5-2013  Electrical Apparatus for Use in the Presence of Combustible Dust - Part 5: Protection by Enclosures “tD” (English Version)
Standard No.GB 12476.5-2013
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count6000 words
Price(USD)160.0
Implemented on2014-11-14
Deliveryvia email in 1 business day
Detail of GB 12476.5-2013
Standard No.
GB 12476.5-2013
English Name
Electrical Apparatus for Use in the Presence of Combustible Dust - Part 5: Protection by Enclosures “tD”
Chinese Name
可燃性粉尘环境用电气设备 第5部分:外壳保护型tD
Chinese Classification
K35
Professional Classification
GB
ICS Classification
Issued by
AQSIQ;SAC
Issued on
2013-12-17
Implemented on
2014-11-14
Status
superseded
Superseded by
GB/T 3836.31-2021 Explosive atmospheres—Part 31:Equipment dust ignition protection by enclosure “t”
Superseded on
2022-5-1
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
6000 words
Price(USD)
160.0
Keywords
GB 12476.5-2013, GB/T 12476.5-2013, GBT 12476.5-2013, GB12476.5-2013, GB 12476.5, GB12476.5, GB/T12476.5-2013, GB/T 12476.5, GB/T12476.5, GBT12476.5-2013, GBT 12476.5, GBT12476.5
Introduction of GB 12476.5-2013
1 Scope This part of GB 12476 is applicable to electrical apparatus protected by enclosures and surface temperature limitation for use in areas where combustible dust may be present in quantities which could lead to a fire or explosion hazard. It specifies requirements for design, construction and testing of electrical apparatus. This part supplements the general requirements in GB 12476.1. Note: GB 12476.2 gives guidance on the selection and installation of the apparatus. Apparatus within the scope of this part may also be subjected to additional requirements in other standards – for example, GB 3836.1. The ignition protection is based on the limitation of the maximum surface temperature of the enclosure and on other surfaces which could be in contact with dust and on the restriction of dust ingress into the enclosure by the use of "dust-tight" or "dust-protected" enclosures. The application of electrical apparatus in atmospheres which may contain explosive gas as well as combustible dust, whether simultaneously or separately, requires additional protective measures. Where the apparatus must meet other environmental conditions, for example, protection against ingress of water and resistance to corrosion, additional methods of protection may be necessary. The method used should not adversely affect the integrity of the enclosure. This part does not apply to dusts of explosives which do not require atmospheric oxygen for combustion, or to pyrophoric substances. This part is not applicable to electrical apparatus intended for use in underground parts of mines as well as those parts of surface installations of such mines endangered by firedamp and/or combustible dust. This part does not take account of any risk due to an emission of flammable or toxic gas from the dust. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB 4208-2008 Degrees of protection provided by enclosure(IP code) (IEC 60529: 2001, IDT) IEC 61241-0: 2013 Electrical apparatus for use in the presence of combustible dust Part 0: General requirements) 3 Terms and definitions For the purposes of this document, the terms and definitions given in IEC 61241-0, as well as the following definitions, apply. 3.1 dust ignition protection type “tD” all relevant measures applied to electrical apparatus protected by an enclosure to avoid ignition of a dust layer or cloud
Contents of GB 12476.5-2013
Foreword I Introduction III 1 Scope 2 Normative references 3 Terms and definitions 4 Construction 5 Practice A and practice B 6 Supplementary requirements for electrical apparatus protected by enclosures for practice A for use in zones 20, 21 and 7 Supplementary requirements for electrical apparatus protected by enclosures for practice B for use in zone 20 or 8 Verification and tests 9 Marking Bibliography
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 12476.5-2013, GB/T 12476.5-2013, GBT 12476.5-2013, GB12476.5-2013, GB 12476.5, GB12476.5, GB/T12476.5-2013, GB/T 12476.5, GB/T12476.5, GBT12476.5-2013, GBT 12476.5, GBT12476.5