2025-12-5 10.1.6.65
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB 23864-2023
GB 23864-2023   Firestop material (English Version)
Standard No.: GB 23864-2023 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 13500 words Translation Price(USD):405.0 remind me the price change

Email:

Implemented on:2024-7-1 Delivery: via email in 1~5 business day

→ → →

,,2024-7-1,17F16B9F9C5E2A3D1705396365980
Standard No.: GB 23864-2023
English Name: Firestop material
Chinese Name: 防火封堵材料
Chinese Classification: C84    Fire-fighting equipment and devices
Professional Classification: GB    National Standard
ICS Classification: 13.220.50 13.220.50    Fire-resistance of building materials and elements 13.220.50
Source Content Issued by: SAMR; SAC
Issued on: 2023-12-28
Implemented on: 2024-7-1
Status: valid
Superseding:GB 23864-2009 Firestop material
Target Language: English
File Format: PDF
Word Count: 13500 words
Translation Price(USD): 405.0
Delivery: via email in 1~5 business day
Firestop material 1 Scope This document specifies the classification and labeling, requirements, test methods, inspection rules as well as packaging, marking, storage and transportation of firestop material. This document is applicable to firestop material or firestop subassembly used in various through-holes and structural joints in industrial and civil buildings, structures and facilities. This document is not applicable to fire intumescent seals and fire stopping collar of PVC-U pipe for building drainage used inside building accessories. 2 Normative references The following documents contain requirements which, through reference in this text, constitute provisions of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 2611 Testing machines - General requirements GB/T 5455 Textiles - Burning behaviour - Determination of damaged length, afterglow time and afterflame time of vertically oriented specimens GB/T 7019-2014 Test methods for fiber cement products GB/T 7106 Test methods of air permeability, watertightness, wind load resistance performance for building external windows and doors GB 8624 Classification for burning behavior of building materials and products GB/T 8626 Test method of flammability for building materials GB/T 9978.1 Fire-resistance tests - Elements of building construction - Part 1: General requirements GB/T 20285 Toxic classification of fire effluents hazard for materials XF/T 714-2007 Rapid rise fire test methods of fire protection materials for structural elements 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 firestop material material with the function of fire prevention and smoke prevention, which is used for sealing or filling through-holes, annular joints and building joints in buildings, structures and various facilities, is convenient for replacement and meets relevant performance requirements 3.2 firestop subassembly subassembly composed of various firestop materials and fireproof heat insulation materials, which is used to maintain the fire resistance of the structure and is convenient to replace 3.3 moveable joint joint with variable width or position due to deformation after heating 3.4 percent for cable penetration area percent for pipe penetration area percentage of the cross-sectional area of cable and pipe penetrations to the cross-sectional area of holes 4 Classification and labeling 4.1 Classification 4.1.1 Firestop material may be classified into three categories according to their uses: firestop material for holes, firestop material for joints and firestop material for plastic pipes. a) The firestop material for holes is used for sealing and filling through-holes, which is indicated by code K. b) The firestop material for joints is used for sealing and filling joints (such as expansion joints, settlement joints, seismic joints, structural joints, etc.) between fireproof partition members or between fireproof partition members and other members, such as fireproof sealant and joint filling material, which is indicated by code F. c) The firestop material for plastic pipes is used for sealing and filling the place where plastic pipes pass through holes in walls or floors, which is indicated by code S.
Foreword i 1 Scope 2 Normative references 3 Terms and definitions 4 Classification and labeling 4.1 Classification 4.2 Labeling 5 Requirements 5.1 General requirements 5.2 Physical and chemical properties 5.3 Combustion property 5.4 Toxicity of fire effluents 5.5 Air tightness 5.6 Fire resistance 5.7 Flushing test performance 6 Test methods 6.1 Physical and chemical properties 6.2 Combustion property 6.3 Toxicity of fire effluents 6.4 Air tightness 6.5 Fire resistance 7 Inspection rules 7.1 Inspection classification 7.2 Comprehensive judgment criteria 7.3 Use of fire resistance test result 8 Packaging, marking, storage and transportation Annex A (Normative) Installation of standard specimens for fire resistance test of firestop material Annex B (Informative) Installation of typical specimens for fire resistance test of firestop subassembly Annex C (Normative) Optional and additional test of firestop material and firestop subassembly - Flushing test Annex D (Informative) Use of fire resistance test result
Referred in GB 23864-2023:
*GB/T 2611-2022 Testing machines—General requirements
*GB/T 5455-2014 Textiles―Burning behaviour―Determination of damaged length,afterglow time and afterflame time of vertically oriented specimens
*GB/T 7019-2014 Test methods for fiber cement products
*GB/T 7106-2019 Test methods of air permeability,watertightness,wind load resistance performance for building external windows and doors
*GB 8624-2012 Classification for burning behavior of building materials and products
*GB/T 8626-2007 Test Method of Flammability for Building Materials
*GB/T 9978.1-2008 Fire-Resistance Tests-Elements of Building Construction Part1: General Requirements
*GB/T 20285-2006 Toxic classification of fire effluents hazard for materials
*XF/T 714-2007 Rapid rise fire test methods of fire protection materials for structural elements
Code of China
Standard
GB 23864-2023  Firestop material (English Version)
Standard No.GB 23864-2023
Statusvalid
LanguageEnglish
File FormatPDF
Word Count13500 words
Price(USD)405.0
Implemented on2024-7-1
Deliveryvia email in 1~5 business day
Detail of GB 23864-2023
Standard No.
GB 23864-2023
English Name
Firestop material
Chinese Name
防火封堵材料
Chinese Classification
C84
Professional Classification
GB
ICS Classification
Issued by
SAMR; SAC
Issued on
2023-12-28
Implemented on
2024-7-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
GB 23864-2009 Firestop material
Language
English
File Format
PDF
Word Count
13500 words
Price(USD)
405.0
Keywords
GB 23864-2023, GB/T 23864-2023, GBT 23864-2023, GB23864-2023, GB 23864, GB23864, GB/T23864-2023, GB/T 23864, GB/T23864, GBT23864-2023, GBT 23864, GBT23864
Introduction of GB 23864-2023
Firestop material 1 Scope This document specifies the classification and labeling, requirements, test methods, inspection rules as well as packaging, marking, storage and transportation of firestop material. This document is applicable to firestop material or firestop subassembly used in various through-holes and structural joints in industrial and civil buildings, structures and facilities. This document is not applicable to fire intumescent seals and fire stopping collar of PVC-U pipe for building drainage used inside building accessories. 2 Normative references The following documents contain requirements which, through reference in this text, constitute provisions of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 2611 Testing machines - General requirements GB/T 5455 Textiles - Burning behaviour - Determination of damaged length, afterglow time and afterflame time of vertically oriented specimens GB/T 7019-2014 Test methods for fiber cement products GB/T 7106 Test methods of air permeability, watertightness, wind load resistance performance for building external windows and doors GB 8624 Classification for burning behavior of building materials and products GB/T 8626 Test method of flammability for building materials GB/T 9978.1 Fire-resistance tests - Elements of building construction - Part 1: General requirements GB/T 20285 Toxic classification of fire effluents hazard for materials XF/T 714-2007 Rapid rise fire test methods of fire protection materials for structural elements 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 firestop material material with the function of fire prevention and smoke prevention, which is used for sealing or filling through-holes, annular joints and building joints in buildings, structures and various facilities, is convenient for replacement and meets relevant performance requirements 3.2 firestop subassembly subassembly composed of various firestop materials and fireproof heat insulation materials, which is used to maintain the fire resistance of the structure and is convenient to replace 3.3 moveable joint joint with variable width or position due to deformation after heating 3.4 percent for cable penetration area percent for pipe penetration area percentage of the cross-sectional area of cable and pipe penetrations to the cross-sectional area of holes 4 Classification and labeling 4.1 Classification 4.1.1 Firestop material may be classified into three categories according to their uses: firestop material for holes, firestop material for joints and firestop material for plastic pipes. a) The firestop material for holes is used for sealing and filling through-holes, which is indicated by code K. b) The firestop material for joints is used for sealing and filling joints (such as expansion joints, settlement joints, seismic joints, structural joints, etc.) between fireproof partition members or between fireproof partition members and other members, such as fireproof sealant and joint filling material, which is indicated by code F. c) The firestop material for plastic pipes is used for sealing and filling the place where plastic pipes pass through holes in walls or floors, which is indicated by code S.
Contents of GB 23864-2023
Foreword i 1 Scope 2 Normative references 3 Terms and definitions 4 Classification and labeling 4.1 Classification 4.2 Labeling 5 Requirements 5.1 General requirements 5.2 Physical and chemical properties 5.3 Combustion property 5.4 Toxicity of fire effluents 5.5 Air tightness 5.6 Fire resistance 5.7 Flushing test performance 6 Test methods 6.1 Physical and chemical properties 6.2 Combustion property 6.3 Toxicity of fire effluents 6.4 Air tightness 6.5 Fire resistance 7 Inspection rules 7.1 Inspection classification 7.2 Comprehensive judgment criteria 7.3 Use of fire resistance test result 8 Packaging, marking, storage and transportation Annex A (Normative) Installation of standard specimens for fire resistance test of firestop material Annex B (Informative) Installation of typical specimens for fire resistance test of firestop subassembly Annex C (Normative) Optional and additional test of firestop material and firestop subassembly - Flushing test Annex D (Informative) Use of fire resistance test result
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 23864-2023, GB/T 23864-2023, GBT 23864-2023, GB23864-2023, GB 23864, GB23864, GB/T23864-2023, GB/T 23864, GB/T23864, GBT23864-2023, GBT 23864, GBT23864