2025-12-5 10.1.6.65
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/JG/T 497-2016
JG/T 497-2016   High-efficient Filters for Air Exhaust (English Version)
Standard No.: JG/T 497-2016 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 6000 words Translation Price(USD):120.0 remind me the price change

Email:

Implemented on:2016-12-1 Delivery: via email in 1 business day

→ → →

,,2016-12-1,022F745E997ED55F1469074774915
Standard No.: JG/T 497-2016
English Name: High-efficient Filters for Air Exhaust
Chinese Name: 排风高效过滤装置
Chinese Classification: P48    Ventilation and air conditioning engineering
Professional Classification: JG    Professional Standard - Building
ICS Classification: 91.140.01 91.140.01    Installations in buildings in general 91.140.01
Source Content Issued by: MOHURD
Issued on: 2016-06-14
Implemented on: 2016-12-1
Status: valid
Target Language: English
File Format: PDF
Word Count: 6000 words
Translation Price(USD): 120.0
Delivery: via email in 1 business day
1 Scope This standard specifies terms and definitions, classification and marking, materials, requirements, test methods, inspection rules as well as sign, packaging, transport and storage of exhaust high efficiency filtration units. This standard is applicable to exhaust high efficiency filtration units used to remove harmful bio-aerosol from Biosafety Level 3 or higher facilities. Reference may be made to this standard for the exhaust high efficiency filtration units for similar purposes. This standard is not applicable to exhaust high efficiency filtration units for removing radioactive aerosol. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 191 Packaging - Pictorial marking for handling of goods GB/T 6165 Test method of the performance of high efficiency particulate air filter - Efficiency and resistance GB/T 13554 High efficiency particulate air filter GB 18457 Stainless steel needle tubing for manufacture of medical devices GB 19489 Laboratories - General requirements for biosafety GB 50346 Architectural and technical code for biosafety laboratories GB 50591 Code for construction and acceptance of cleanroom 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 exhaust high efficiency filtration units filtration unit used in specific biorisk environment to remove harmful bio-aerosol in exhaust, which has the functions of in-situ disinfection and leak detection 3.2 aerosol relatively stable dispersion system formed by solid or liquid fine particles which, with a particle size of 0.001 μm to 100 μm, suspend in gaseous medium [GB 19489-2008, Definition 2.1] 3.3 bio-aerosol aerosol containing biological factor 3.4 high efficiency particulate air filter air filter used for air filtration and conforming to GB 13554
Foreword i 1 Scope 2 Normative references 3 Terms and definitions 4 Classification and marking 5 Materials 6 Requirements 7 Test methods 8 Inspection rules 9 Sign, packaging, transport and storage Annex A (Normative) Tightness detection method Annex B (Informative) Alternating pressure tightness detection method Annex C (Normative) Method for aerosol concentration uniformity test
Referred in JG/T 497-2016:
*GB/T 191-2008 Packaging - Pictorial Marking for Handling of Goods
*GB/T 6165-2008 Test methed of the performance of high efficiency particulate air filter - Efficiency and risistance
*GB/T 13554-2020 High efficiency particulate air filter
*GB 18457-2001 Stainless steel needle tubing for manufacture of medical devices
*GB 19489-2008 Laboratories - General Requirements for Biosafety
*GB 50346-2011 Architectural and technical code for biosafety laboratories
*GB 50591-2010 Code for Construction and Acceptance of Cleanroom
Code of China
Standard
JG/T 497-2016  High-efficient Filters for Air Exhaust (English Version)
Standard No.JG/T 497-2016
Statusvalid
LanguageEnglish
File FormatPDF
Word Count6000 words
Price(USD)120.0
Implemented on2016-12-1
Deliveryvia email in 1 business day
Detail of JG/T 497-2016
Standard No.
JG/T 497-2016
English Name
High-efficient Filters for Air Exhaust
Chinese Name
排风高效过滤装置
Chinese Classification
P48
Professional Classification
JG
ICS Classification
Issued by
MOHURD
Issued on
2016-06-14
Implemented on
2016-12-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
6000 words
Price(USD)
120.0
Keywords
JG/T 497-2016, JG 497-2016, JGT 497-2016, JG/T497-2016, JG/T 497, JG/T497, JG497-2016, JG 497, JG497, JGT497-2016, JGT 497, JGT497
Introduction of JG/T 497-2016
1 Scope This standard specifies terms and definitions, classification and marking, materials, requirements, test methods, inspection rules as well as sign, packaging, transport and storage of exhaust high efficiency filtration units. This standard is applicable to exhaust high efficiency filtration units used to remove harmful bio-aerosol from Biosafety Level 3 or higher facilities. Reference may be made to this standard for the exhaust high efficiency filtration units for similar purposes. This standard is not applicable to exhaust high efficiency filtration units for removing radioactive aerosol. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 191 Packaging - Pictorial marking for handling of goods GB/T 6165 Test method of the performance of high efficiency particulate air filter - Efficiency and resistance GB/T 13554 High efficiency particulate air filter GB 18457 Stainless steel needle tubing for manufacture of medical devices GB 19489 Laboratories - General requirements for biosafety GB 50346 Architectural and technical code for biosafety laboratories GB 50591 Code for construction and acceptance of cleanroom 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 exhaust high efficiency filtration units filtration unit used in specific biorisk environment to remove harmful bio-aerosol in exhaust, which has the functions of in-situ disinfection and leak detection 3.2 aerosol relatively stable dispersion system formed by solid or liquid fine particles which, with a particle size of 0.001 μm to 100 μm, suspend in gaseous medium [GB 19489-2008, Definition 2.1] 3.3 bio-aerosol aerosol containing biological factor 3.4 high efficiency particulate air filter air filter used for air filtration and conforming to GB 13554
Contents of JG/T 497-2016
Foreword i 1 Scope 2 Normative references 3 Terms and definitions 4 Classification and marking 5 Materials 6 Requirements 7 Test methods 8 Inspection rules 9 Sign, packaging, transport and storage Annex A (Normative) Tightness detection method Annex B (Informative) Alternating pressure tightness detection method Annex C (Normative) Method for aerosol concentration uniformity test
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
JG/T 497-2016, JG 497-2016, JGT 497-2016, JG/T497-2016, JG/T 497, JG/T497, JG497-2016, JG 497, JG497, JGT497-2016, JGT 497, JGT497