2025-12-5 10.1.6.65
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/JJG 1055-2009
JJG 1055-2009   On-line Gas Chromatograph (English Version)
Standard No.: JJG 1055-2009 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 7000 words Translation Price(USD):170.0 remind me the price change

Email:

Implemented on:2010-1-9 Delivery: via email in 1 business day

→ → →

,,2010-1-9,1411376763411068D3DB3D12BE941
Standard No.: JJG 1055-2009
English Name: On-line Gas Chromatograph
Chinese Name: 在线气相色谱仪
Professional Classification: JJ    Metering
Source Content Issued by: AQSIQ
Issued on: 2009-10-9
Implemented on: 2010-1-9
Status: valid
Target Language: English
File Format: PDF
Word Count: 7000 words
Translation Price(USD): 170.0
Delivery: via email in 1 business day
1 Application Scope This regulation is applicable to initial verification, subsequent verification and in-use inspection of on-line gas chromatograph for gas trade transaction and atmospheric environment testing and analysis (hereinafter referred as “the instrument”). This regulation is also used as a reference for measurement performance test of the on-line gas chromatograph in type evaluation and stereotyping appraisement. 2 General The on-line gas chromatograph is an instrument that is installed at the working site, directly connected to the object to be measured through the gas pipeline, and automatically measures the content of the corresponding gas components through automatic acquisition and automatic injection, and can store and remotely transmit the measurement results. It is mainly used for real-time continuous detection of gas component content in natural gas or atmospheric environment. 3 Metrological Performance Requirements On-line gas chromatograph shall be in accordance with Table 1 for its major metrological performance.
1 Application Scope 2 General 3 Metrological Performance Requirements 4 General Technical Requirements 5 Measuring Instrument Control 5.1 Verification Conditions 5.2 Verification Items 5.3 Verification Method 5.4 Treatment of Verification Results 5.5 Verification Cycle Annex A Reference Format of Verification Certificate (Inside Page) Annex B Reference Format of Verification Result Notice (Inside Page) Annex C Reference Format of Verification Record Annex D Calibration of Carrier Gas Flow Rate Annex E Reference Content of Each Component in Natural Gas Standard Gas
JJG 1055-2009 is referred in:
*GB/T 18603-2014 Technical requirements of measuring systems for natural gas
Code of China
Standard
JJG 1055-2009  On-line Gas Chromatograph (English Version)
Standard No.JJG 1055-2009
Statusvalid
LanguageEnglish
File FormatPDF
Word Count7000 words
Price(USD)170.0
Implemented on2010-1-9
Deliveryvia email in 1 business day
Detail of JJG 1055-2009
Standard No.
JJG 1055-2009
English Name
On-line Gas Chromatograph
Chinese Name
在线气相色谱仪
Chinese Classification
Professional Classification
JJ
ICS Classification
Issued by
AQSIQ
Issued on
2009-10-9
Implemented on
2010-1-9
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
7000 words
Price(USD)
170.0
Keywords
JJG 1055-2009, JJG/T 1055-2009, JJGT 1055-2009, JJG1055-2009, JJG 1055, JJG1055, JJG/T1055-2009, JJG/T 1055, JJG/T1055, JJGT1055-2009, JJGT 1055, JJGT1055
Introduction of JJG 1055-2009
1 Application Scope This regulation is applicable to initial verification, subsequent verification and in-use inspection of on-line gas chromatograph for gas trade transaction and atmospheric environment testing and analysis (hereinafter referred as “the instrument”). This regulation is also used as a reference for measurement performance test of the on-line gas chromatograph in type evaluation and stereotyping appraisement. 2 General The on-line gas chromatograph is an instrument that is installed at the working site, directly connected to the object to be measured through the gas pipeline, and automatically measures the content of the corresponding gas components through automatic acquisition and automatic injection, and can store and remotely transmit the measurement results. It is mainly used for real-time continuous detection of gas component content in natural gas or atmospheric environment. 3 Metrological Performance Requirements On-line gas chromatograph shall be in accordance with Table 1 for its major metrological performance.
Contents of JJG 1055-2009
1 Application Scope 2 General 3 Metrological Performance Requirements 4 General Technical Requirements 5 Measuring Instrument Control 5.1 Verification Conditions 5.2 Verification Items 5.3 Verification Method 5.4 Treatment of Verification Results 5.5 Verification Cycle Annex A Reference Format of Verification Certificate (Inside Page) Annex B Reference Format of Verification Result Notice (Inside Page) Annex C Reference Format of Verification Record Annex D Calibration of Carrier Gas Flow Rate Annex E Reference Content of Each Component in Natural Gas Standard Gas