This Code specifies the basic lighting requirements of designing fossil fuel power plants and substations.
This Code is applicable to the lighting design of newly-built, extended and reconstructed fossil fuel power plants and substations
Foreword II
1. Scope
2. Normative References
3. Terms and Definitions
4. General Provisions
5. Lighting Way and Variety
5.1 Lighting way
5.2 Lighting variety
6. Illuminant
7. Selection and Arrangement of Luminaire and Attachment
7.1 Luminaire selection
7.2 Distribution of indoor lighting luminaire
7.3 Distribution of outdoor lighting luminaire
7.4 Obstacle lighting
7.5 Installation of lighting fixture and attachment
7.6 Selection and installation of light switch and socket
8. Lighting Standard Value
9. Illumination Calculation
10. Power Supply and Control of Lighting Network
10.1 Voltage of lighting network
10.2 Power supply of normal lighting network
10.3 Power supply of emergency lighting network
10.4 Power supply circuit for lighting
10.5 Calculation of lighting load
10.6 Selection of conductor cross-section
10.7 Laying and controlling of lighting lines
10.8 Selection and arrangement of lighting distribution boxes
10.9 Grounding of lighting network
11. Lighting Quality
12. Lighting Energy Conservation
Annex A (Informative) Lighting Fixture Technologies of Fossil Fuel Power Plants and Substations
Annex B (Informative) Illuminance Calculation Examples
Annex C (Informative) Lasting Allowed Current Capacity of the 500V Single-Core Plastic Insulating Conductor (PIC)
Annex D (Informative) Current Capacity when Open Laying 500V Plastic Sheathed Conductor
Annex E (Informative) Temperature Correction Factor of the Current Capacity of the Conductor
Annex F (Informative) 500V PIC Poling Complexing
Annex G (Normative) Unified Glare Rating (UGR)
This Code specifies the basic lighting requirements of designing fossil fuel power plants and substations.
This Code is applicable to the lighting design of newly-built, extended and reconstructed fossil fuel power plants and substations
Contents of DL/T 5390-2007
Foreword II
1. Scope
2. Normative References
3. Terms and Definitions
4. General Provisions
5. Lighting Way and Variety
5.1 Lighting way
5.2 Lighting variety
6. Illuminant
7. Selection and Arrangement of Luminaire and Attachment
7.1 Luminaire selection
7.2 Distribution of indoor lighting luminaire
7.3 Distribution of outdoor lighting luminaire
7.4 Obstacle lighting
7.5 Installation of lighting fixture and attachment
7.6 Selection and installation of light switch and socket
8. Lighting Standard Value
9. Illumination Calculation
10. Power Supply and Control of Lighting Network
10.1 Voltage of lighting network
10.2 Power supply of normal lighting network
10.3 Power supply of emergency lighting network
10.4 Power supply circuit for lighting
10.5 Calculation of lighting load
10.6 Selection of conductor cross-section
10.7 Laying and controlling of lighting lines
10.8 Selection and arrangement of lighting distribution boxes
10.9 Grounding of lighting network
11. Lighting Quality
12. Lighting Energy Conservation
Annex A (Informative) Lighting Fixture Technologies of Fossil Fuel Power Plants and Substations
Annex B (Informative) Illuminance Calculation Examples
Annex C (Informative) Lasting Allowed Current Capacity of the 500V Single-Core Plastic Insulating Conductor (PIC)
Annex D (Informative) Current Capacity when Open Laying 500V Plastic Sheathed Conductor
Annex E (Informative) Temperature Correction Factor of the Current Capacity of the Conductor
Annex F (Informative) 500V PIC Poling Complexing
Annex G (Normative) Unified Glare Rating (UGR)