2023-3-24 44.200.168.16
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB 27898.1-2011
GB 27898.1-2011   Fixed water supply equipment used for fire-protection - Part 1: Gas pressure fixed water supply equipment used for fire-protection (English Version)
Standard No.: GB 27898.1-2011 Status:valid remind me the status change

Email:

Language:English File Format:PDF
Word Count: 10000 words Price(USD):300.0 remind me the price change

Email:

Implemented on:2012-6-1 Delivery: via email in 1 business day
,,
Standard No.: GB 27898.1-2011
English Name: Fixed water supply equipment used for fire-protection - Part 1: Gas pressure fixed water supply equipment used for fire-protection
Chinese Name: 固定消防给水设备 第1部分:消防气压给水设备
Chinese Classification: C84    Fire-fighting equipment and devices
Professional Classification: GB    National Standard
ICS Classification: 13.220.10 13.220.10    Fire-fighting 13.220.10
Issued by: AQSIQ, SAC
Issued on: 2011-12-30
Implemented on: 2012-6-1
Status: valid
Language: English
File Format: PDF
Word Count: 10000 words
Price(USD): 300.0
Delivery: via email in 1 business day
Fixed water supply equipment used for fire-protection - Part 1: Gas pressure fixed water supply equipment used for fire-protection 1 Scope This part of GB 27898 specifies the terms and definitions, classification, requirements, test methods, inspection rules, signboard and operation instructions, packaging, transportation and storage of gas pressure fixed water supply equipment used for fire-protection. This part is applicable to gas pressure fixed water supply equipment used for fire-protection. As for gas pressure fixed water supply equipment used for fire-protection with a similar working principle, this part may be adopted by reference. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB 150 Steel pressure vessels GB/T 528 Rubber, vulcanized or thermoplastic - Determination of tensile stress-strain properties GB/T 3047.1 Series of basic dimensions of panels, rack and cabinets for vertical increment of 20mm GB/T 3222.2 Acoustics - Description, measurement and assessment of environmental noise - Part 2: Determination of environmental noise levels GB/T 3797 Electrical control assemblies GB/T 4208 Degrees of protection provided by enclosure (IP code) GB 5135.7 Automatic sprinkler systems - Part 7: Water flow indicators GB 5135.10 Automatic sprinkler system - Part 10: Pressure switch GB 6245 Fire pumps GB 7251.1 Low-voltage switchgear and controlgear assemblies - Part 1: Type-tested and partially type-tested assemblies CJ/T 160 Double check valve backflow prevention assembly TSG R0004 Supervision regulation on safety technology for stationary pressure vessel 3 Terms and definitions For the purposes of this standard, the following terms and definitions apply. 3.1 fixed water supply equipment used for fire-protection general term for a complete set of equipment fixedly installed in a building, to be equipped with components according to the needs of water fire extinguishing system and supply fire water according to the preset working mode 3.2 gas pressure fixed water supply equipment used for fire-protection fixed water supply equipment used for fire-protection with water tank with pressurized gas as its core component, supplying water continuously to fire-protection pipe network at the set pressure 3.3 emergency type gas pressure fixed water supply equipment without fire pump used for fire-protection gas pressure water supply equipment which relies on the effective water volume for fire protection discharged from the water tank with pressurized gas to meet the water demand at the initial stage of fire protection and which is not equipped with a fire pump set 3.4 pressurization type gas pressure fixed water supply equipment with fire pump used for fire-protection gas pressure water supply equipment which is additionally equipped with fire pump set on the basis of emergency type gas pressure fixed water supply equipment without fire pump used for fire-protection, and which can supply pressurized water in case of fire-protection condition 3.5 water tank with pressurized gas pressure vessel which can store water and gas, and work according to Boyle's law to supply water by using the expansion characteristics of compressed gas 3.6 pressurized gas shut off unit device for preventing the gas in the water tank with pressurized gas from leaking to the water supply pipe network to maintain the normal operation of the system   3.7 upper limit of stabilizing pressure, p4 maximum pressure for the fixed water supply equipment used for fire-protection to maintain normal stable pressure operation, that is, the pressure in the water tank with pressurized gas when water supply is stopped 3.8 lower limit of stabilizing pressure, p3 minimum pressure for the fixed water supply equipment used for fire-protection to maintain normal stable pressure operation, that is, the pressure in the water tank with pressurized gas when water supply starts 3.9 gas supply pressure setpoint, p1 operating pressure of pressurized gas shut off unit for water tank with pressurized gas of air replenishment type or in-tank or in-capsule gas-filling pressure of capsule-type water tank with pressurized gas 3.10 effective water volume for fire protection, V3 water consumption at the initial stage of fire protection provided by water tank with pressurized gas, which can meet the water supply pressure at the most unfavorable point of the system, which is generally the amount of water discharged by water tank with pressurized gas from the lower limit of stabilizing pressure (p3) to gas supply pressure setpoint (p1)
Foreword II 1 Scope 2 Normative references 3 Terms and definitions 4 Classification 5 Requirements 6 Test methods 7 Inspection rules 8 Signboard and operation instructions 9 Packaging, transportation and storage Annex A (Informative) Sampling and judgment of fixed water supply equipment series used for fire-protection
Referred in GB 27898.1-2011:
*GB 150-2011 Pressure Vessels (Collection GB150.1~150.4-2011)
*GB/T 528-2009 Rubber,vulcanized or thermoplastic - Determination of tensile stress-strain properties
*GB/T 3047.1-1995 Series of basic dimensions of panels, rack and cabinets for vertical increment of 20mm
*GB/T 3222.2-2009 Acoustics—Description measurement and assessment of environmental noise—Part 2:Determination of environmental noise levels
*GB/T 3797-2016 Electrical control assemblies
*GB/T 4208-2017 Degrees of protection provided by enclosure(IP code)
*GB 5135.7-2018 Automatic sprinkler systems—Part 7:Water flow indicators
*GB 5135.10-2006 Automatic sprinkler system-Part10:Pressure switch
*GB 6245-2006 Fire Pumps
*GB 7251.1-2013 Low-voltage switchgear and controlgear assemblies-Part 1:General rules
*CJ/T160-2002
*TSG R0004-2009 Supervision Regulation on Safety Technology for Stationary Pressure Vessel (including Amendment 1)
GB 27898.1-2011 is referred in:
*GB 27898.3-2011 Fixed water supply equipment used for fire-protection - Part 3: Pressure boosting and stabilizing type water supply equipment used for fire-protection
*GB 27898.2-2011 Fixed water supply equipment used for fire-protection - Part 2: Constant pressure automatic water supply equipment used for fire-protection
Code of China
Standard
GB 27898.1-2011  Fixed water supply equipment used for fire-protection - Part 1: Gas pressure fixed water supply equipment used for fire-protection (English Version)
Standard No.GB 27898.1-2011
Statusvalid
LanguageEnglish
File FormatPDF
Word Count10000 words
Price(USD)300.0
Implemented on2012-6-1
Deliveryvia email in 1 business day
Detail of GB 27898.1-2011
Standard No.
GB 27898.1-2011
English Name
Fixed water supply equipment used for fire-protection - Part 1: Gas pressure fixed water supply equipment used for fire-protection
Chinese Name
固定消防给水设备 第1部分:消防气压给水设备
Chinese Classification
C84
Professional Classification
GB
ICS Classification
Issued by
AQSIQ, SAC
Issued on
2011-12-30
Implemented on
2012-6-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
10000 words
Price(USD)
300.0
Keywords
GB 27898.1-2011, GB/T 27898.1-2011, GBT 27898.1-2011, GB27898.1-2011, GB 27898.1, GB27898.1, GB/T27898.1-2011, GB/T 27898.1, GB/T27898.1, GBT27898.1-2011, GBT 27898.1, GBT27898.1
Introduction of GB 27898.1-2011
Fixed water supply equipment used for fire-protection - Part 1: Gas pressure fixed water supply equipment used for fire-protection 1 Scope This part of GB 27898 specifies the terms and definitions, classification, requirements, test methods, inspection rules, signboard and operation instructions, packaging, transportation and storage of gas pressure fixed water supply equipment used for fire-protection. This part is applicable to gas pressure fixed water supply equipment used for fire-protection. As for gas pressure fixed water supply equipment used for fire-protection with a similar working principle, this part may be adopted by reference. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB 150 Steel pressure vessels GB/T 528 Rubber, vulcanized or thermoplastic - Determination of tensile stress-strain properties GB/T 3047.1 Series of basic dimensions of panels, rack and cabinets for vertical increment of 20mm GB/T 3222.2 Acoustics - Description, measurement and assessment of environmental noise - Part 2: Determination of environmental noise levels GB/T 3797 Electrical control assemblies GB/T 4208 Degrees of protection provided by enclosure (IP code) GB 5135.7 Automatic sprinkler systems - Part 7: Water flow indicators GB 5135.10 Automatic sprinkler system - Part 10: Pressure switch GB 6245 Fire pumps GB 7251.1 Low-voltage switchgear and controlgear assemblies - Part 1: Type-tested and partially type-tested assemblies CJ/T 160 Double check valve backflow prevention assembly TSG R0004 Supervision regulation on safety technology for stationary pressure vessel 3 Terms and definitions For the purposes of this standard, the following terms and definitions apply. 3.1 fixed water supply equipment used for fire-protection general term for a complete set of equipment fixedly installed in a building, to be equipped with components according to the needs of water fire extinguishing system and supply fire water according to the preset working mode 3.2 gas pressure fixed water supply equipment used for fire-protection fixed water supply equipment used for fire-protection with water tank with pressurized gas as its core component, supplying water continuously to fire-protection pipe network at the set pressure 3.3 emergency type gas pressure fixed water supply equipment without fire pump used for fire-protection gas pressure water supply equipment which relies on the effective water volume for fire protection discharged from the water tank with pressurized gas to meet the water demand at the initial stage of fire protection and which is not equipped with a fire pump set 3.4 pressurization type gas pressure fixed water supply equipment with fire pump used for fire-protection gas pressure water supply equipment which is additionally equipped with fire pump set on the basis of emergency type gas pressure fixed water supply equipment without fire pump used for fire-protection, and which can supply pressurized water in case of fire-protection condition 3.5 water tank with pressurized gas pressure vessel which can store water and gas, and work according to Boyle's law to supply water by using the expansion characteristics of compressed gas 3.6 pressurized gas shut off unit device for preventing the gas in the water tank with pressurized gas from leaking to the water supply pipe network to maintain the normal operation of the system   3.7 upper limit of stabilizing pressure, p4 maximum pressure for the fixed water supply equipment used for fire-protection to maintain normal stable pressure operation, that is, the pressure in the water tank with pressurized gas when water supply is stopped 3.8 lower limit of stabilizing pressure, p3 minimum pressure for the fixed water supply equipment used for fire-protection to maintain normal stable pressure operation, that is, the pressure in the water tank with pressurized gas when water supply starts 3.9 gas supply pressure setpoint, p1 operating pressure of pressurized gas shut off unit for water tank with pressurized gas of air replenishment type or in-tank or in-capsule gas-filling pressure of capsule-type water tank with pressurized gas 3.10 effective water volume for fire protection, V3 water consumption at the initial stage of fire protection provided by water tank with pressurized gas, which can meet the water supply pressure at the most unfavorable point of the system, which is generally the amount of water discharged by water tank with pressurized gas from the lower limit of stabilizing pressure (p3) to gas supply pressure setpoint (p1)
Contents of GB 27898.1-2011
Foreword II 1 Scope 2 Normative references 3 Terms and definitions 4 Classification 5 Requirements 6 Test methods 7 Inspection rules 8 Signboard and operation instructions 9 Packaging, transportation and storage Annex A (Informative) Sampling and judgment of fixed water supply equipment series used for fire-protection
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Foryou Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 27898.1-2011, GB/T 27898.1-2011, GBT 27898.1-2011, GB27898.1-2011, GB 27898.1, GB27898.1, GB/T27898.1-2011, GB/T 27898.1, GB/T27898.1, GBT27898.1-2011, GBT 27898.1, GBT27898.1