Standard No.: GB/T 13729-2002
English Name: Remote terminal unit equipment
Chinese Name: 远动终端设备
Chinese Classification: F21    Electric power system
Professional Classification: GB    National Standard
ICS Classification: 29.240.30 29.240.30    Control equipment for electric power systems 29.240.30
Issued by: AQSIQ
Issued on: 2002-1-1
Implemented on: 2003-6-1
Status: superseded
Superseded by:GB/T 13729-2019 Remote terminal unit equipment
Superseded on:2020-1-1
Superseding:GB/T 13729-1992 General specification for remote terminal unit
Language: English
File Format: PDF
Word Count: 10000 words
Price(USD): 250.0
Delivery: via email in 1 business day
1 Scope This standard specifies technical requirements, test methods, inspection rules as well as marking, packaging, transportation and storage of remote terminal unit equipment. Remote terminal unit equipment generally consists of remote terminal unit (RTU) host, communication interface, remote execution unit and local function unit. This standard is applicable to various remote terminal unit equipment (hereinafter referred to as equipment); and plant/station measurement & control communication unit and microcomputer forwarding equipment may also refer to this standard. 2 Normative References The following documents contain provisions which, through reference in this text, constitute provisions of this standard. For dated references, subsequent amendments to (excluding corrections to) or revisions of, any of these publications do not apply. However, all parties coming to an agreement according to this standard are encouraged to study whether the latest editions of these documents apply. For undated references, the latest editions of the normative documents referred to apply. GB/T 191 Packaging - Pictorial Marking for Handling of Goods (GB/T 191-2000, eqv ISO 780: 1997) GB/T 2421 Environmental Testing for Electric and Electronic Products - Part 1: General and Guidance (GB/T 2421-1999, idt IEC 60068-1: 1988) GB/T 2423.1 Environmental Testings for Electric and Electronic Products - Part 2: Test Methods - Test A: Cold (GB/T 2423.1-2001, idt IEC 60068-2-1: 1990) GB/T 2423.2 Environmental Testings for Electric and Electronic Products - Part 2: Test Methods - Test B: Dry Heat (GB/T 2423.2-2001, idt IEC 60068-2-2: 1974) GB/T 2423.9 Environmental Testing for Electric and Electronic Products - Part 2: Test Methods - Test Cb: Damp Heat, Steady State, Primarily for Equipment (GB/T 2423.9-2001, idt IEC 60068-2-56: 1988) GB/T 2887 Specification for Electronic Computer Field GB/T 3047.4 Series of Basic Dimensions of Subracks and Plug-in Units for Vertical Increment of 44.45mm (neq IEC 297-3) GB 4208 Degrees of Protection Provided by Enclosure (IP Code) (GB 4208-1993, eqv IEC 529: 1989) GB/T 9361-1988 Safety Requirements for Computation Center Field GB/T 15153.1-1998 Telecontrol Equipment and Systems - Part 2: Operating Conditions - Section 1: Power Supply and Electromagnetic Compatibility (idt IEC 60870-2-1: 1995) GB/T 15153.2-2000 Telecontrol equipment and systems - Part 2: Operating Conditions - Section 2: Environmental Conditions (Climatic, Mechanical and Other Non-electrical Influences) (idt IEC 870-2-2: 1996) GB/T 16435.1 Telecontrol Equipment and Systems Interfaces (Electrical Characteristics) (GB/T 16435.1-1996, idt IEC 60870-3: 1989)
Contents Foreword I 1 Scope 2 Normative References 3 Technical Requirements 4 Test Methods 5 Inspection Rules 6 Marking, Packaging, Transportation and Storage 7 Other Appendix A (Normative) Anti-high-frequency Interference Test Circuit Appendix B (Normative) Electrical Fast Transient/Burst Interference Test Circuit Appendix C (Normative) Electrostatic Discharge Test
GB/T 13729-2002 is referred in:
* GB/T 7261-2008 Basic testing method for relaying protection and security automatic equipment
* GB/T 7261-2008 Basic testing method for relaying protection and security automatic equipment
* DL/T 5003-2005 Specifications for the design of dispatch automation in electric power systems
* DL/T 5002-2005 Specifications for the design of dispatch automation in district power networks
* GB/T 26866-2011 Testing specifications of time synchronism systems for power system
* GB/T 31464-2015 The grid operation code
* GB/T 32077-2015 Wind turbine generator system pitch system
*DL/T 1040-2007 The grid operation code
*GB/T 7261-2016 Basic testing method for relaying protection and security automatic equipment
*GB/T 37933-2019 Information security technology—Technical requirements of industrial control system dedicated firewall
Code of China
Standard
GB/T 13729-2002  Remote terminal unit equipment (English Version)
Standard No.GB/T 13729-2002
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count10000 words
Price(USD)250.0
Implemented on2003-6-1
Deliveryvia email in 1 business day
Detail of GB/T 13729-2002
Standard No.
GB/T 13729-2002
English Name
Remote terminal unit equipment
Chinese Name
远动终端设备
Chinese Classification
F21
Professional Classification
GB
ICS Classification
Issued by
AQSIQ
Issued on
2002-1-1
Implemented on
2003-6-1
Status
superseded
Superseded by
GB/T 13729-2019 Remote terminal unit equipment
Superseded on
2020-1-1
Abolished on
Superseding
GB/T 13729-1992 General specification for remote terminal unit
Language
English
File Format
PDF
Word Count
10000 words
Price(USD)
250.0
Keywords
GB/T 13729-2002, GB 13729-2002, GBT 13729-2002, GB/T13729-2002, GB/T 13729, GB/T13729, GB13729-2002, GB 13729, GB13729, GBT13729-2002, GBT 13729, GBT13729
Introduction of GB/T 13729-2002
1 Scope This standard specifies technical requirements, test methods, inspection rules as well as marking, packaging, transportation and storage of remote terminal unit equipment. Remote terminal unit equipment generally consists of remote terminal unit (RTU) host, communication interface, remote execution unit and local function unit. This standard is applicable to various remote terminal unit equipment (hereinafter referred to as equipment); and plant/station measurement & control communication unit and microcomputer forwarding equipment may also refer to this standard. 2 Normative References The following documents contain provisions which, through reference in this text, constitute provisions of this standard. For dated references, subsequent amendments to (excluding corrections to) or revisions of, any of these publications do not apply. However, all parties coming to an agreement according to this standard are encouraged to study whether the latest editions of these documents apply. For undated references, the latest editions of the normative documents referred to apply. GB/T 191 Packaging - Pictorial Marking for Handling of Goods (GB/T 191-2000, eqv ISO 780: 1997) GB/T 2421 Environmental Testing for Electric and Electronic Products - Part 1: General and Guidance (GB/T 2421-1999, idt IEC 60068-1: 1988) GB/T 2423.1 Environmental Testings for Electric and Electronic Products - Part 2: Test Methods - Test A: Cold (GB/T 2423.1-2001, idt IEC 60068-2-1: 1990) GB/T 2423.2 Environmental Testings for Electric and Electronic Products - Part 2: Test Methods - Test B: Dry Heat (GB/T 2423.2-2001, idt IEC 60068-2-2: 1974) GB/T 2423.9 Environmental Testing for Electric and Electronic Products - Part 2: Test Methods - Test Cb: Damp Heat, Steady State, Primarily for Equipment (GB/T 2423.9-2001, idt IEC 60068-2-56: 1988) GB/T 2887 Specification for Electronic Computer Field GB/T 3047.4 Series of Basic Dimensions of Subracks and Plug-in Units for Vertical Increment of 44.45mm (neq IEC 297-3) GB 4208 Degrees of Protection Provided by Enclosure (IP Code) (GB 4208-1993, eqv IEC 529: 1989) GB/T 9361-1988 Safety Requirements for Computation Center Field GB/T 15153.1-1998 Telecontrol Equipment and Systems - Part 2: Operating Conditions - Section 1: Power Supply and Electromagnetic Compatibility (idt IEC 60870-2-1: 1995) GB/T 15153.2-2000 Telecontrol equipment and systems - Part 2: Operating Conditions - Section 2: Environmental Conditions (Climatic, Mechanical and Other Non-electrical Influences) (idt IEC 870-2-2: 1996) GB/T 16435.1 Telecontrol Equipment and Systems Interfaces (Electrical Characteristics) (GB/T 16435.1-1996, idt IEC 60870-3: 1989)
Contents of GB/T 13729-2002
Contents Foreword I 1 Scope 2 Normative References 3 Technical Requirements 4 Test Methods 5 Inspection Rules 6 Marking, Packaging, Transportation and Storage 7 Other Appendix A (Normative) Anti-high-frequency Interference Test Circuit Appendix B (Normative) Electrical Fast Transient/Burst Interference Test Circuit Appendix C (Normative) Electrostatic Discharge Test