CECS 161: 2004   Technical specification for structural strengthening with sprayed concrete (English Version)
Standard No.: CECS 161: 2004 Status:valid remind me the status change

Email:

Language:English File Format:PDF
Word Count: 5000 words Price(USD):100.0 remind me the price change

Email:

Implemented on:2004-5-1 Delivery: via email in 1 business day
,,
Standard No.: CECS 161: 2004
English Name: Technical specification for structural strengthening with sprayed concrete
Chinese Name: 喷射混凝土加固技术规程
Chinese Classification: P25    Concrete structure engineering
Professional Classification: CECS    Engineering Construction Standard
Issued by: CECS
Issued on: 2004-4-5
Implemented on: 2004-5-1
Status: valid
Language: English
File Format: PDF
Word Count: 5000 words
Price(USD): 100.0
Delivery: via email in 1 business day
1.0.1 This Specification is formulated to ensure the sprayed concrete technology (dry-spraying technology, the same below) is correctly used in the design and construction for strengthening and restoration of concrete structure and masonry structure and make the structural strengthening engineering advanced in technology, feasible in economy and guaranteed in quality. 1.0.2 This Specification is applicable to the engineering design and construction for strengthening and restoration of the concrete structure and masonry structure of buildings by way of sprayed concrete technology. This Specification may also be referred to properly in the structural strengthening and restoration of concrete structures and masonry structures for railway engineering, highway engineering and hydraulic & hydroelectric engineering by way of sprayed concrete technology. 1.0.3 Besides this Specification, mandatory provisions in the current relevant national standards shall also be followed in the strengthening and restoration for concrete structure and masonry structure of buildings by way of sprayed concrete technology. Besides this Specification, provisions in the current national special standards shall also be followed in the strengthening and restoration for concrete structure and masonry structure in special environment (such as corrosion and high temperature etc.) by way of sprayed concrete technology.
Foreword I 1 General Provisions 1 2 Terms and Symbols 1 2.1 Term 1 2.2 Symbols 1 3 Materials 2 3.1 Raw Materials for Sprayed Concrete 2 3.2 Admixtures for the Sprayed Concrete 4 3.3 Short Fibre Materials for the Sprayed Concrete 4 3.4 Mix Design of the Sprayed Concrete 5 4 Construction Machines and Tools 5 5 Strengthening Design for the Sprayed Concrete 6 5.1 General Requirements 6 5.2 Strengthening Calculation 7 5.3 Structural Requirements 9 6 Construction Technology 14 6.1 Construction Preparation 14 6.2 Spraying Operation 15 6.3 Safety Measures 16 7 Quality Inspection & Acceptance 17 7.1 Quality Inspection 17 7.2 Acceptance of Works 19 Appendix A Preparation of Standard Test Block for Compressive Strength of Sprayed Concrete 21 Explanation of Wording in This Specification 22
Code of China
Standard
CECS 161: 2004  Technical specification for structural strengthening with sprayed concrete (English Version)
Standard No.CECS 161: 2004
Statusvalid
LanguageEnglish
File FormatPDF
Word Count5000 words
Price(USD)100.0
Implemented on2004-5-1
Deliveryvia email in 1 business day
Detail of CECS 161: 2004
Standard No.
CECS 161: 2004
English Name
Technical specification for structural strengthening with sprayed concrete
Chinese Name
喷射混凝土加固技术规程
Chinese Classification
P25
Professional Classification
CECS
ICS Classification
Issued by
CECS
Issued on
2004-4-5
Implemented on
2004-5-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
5000 words
Price(USD)
100.0
Keywords
CECS 161: 2004, CECS/T 161: 2004, CECST 161: 2004, CECS161:2004, CECS/T161:2004, CECST161:2004,
Introduction of CECS 161: 2004
1.0.1 This Specification is formulated to ensure the sprayed concrete technology (dry-spraying technology, the same below) is correctly used in the design and construction for strengthening and restoration of concrete structure and masonry structure and make the structural strengthening engineering advanced in technology, feasible in economy and guaranteed in quality. 1.0.2 This Specification is applicable to the engineering design and construction for strengthening and restoration of the concrete structure and masonry structure of buildings by way of sprayed concrete technology. This Specification may also be referred to properly in the structural strengthening and restoration of concrete structures and masonry structures for railway engineering, highway engineering and hydraulic & hydroelectric engineering by way of sprayed concrete technology. 1.0.3 Besides this Specification, mandatory provisions in the current relevant national standards shall also be followed in the strengthening and restoration for concrete structure and masonry structure of buildings by way of sprayed concrete technology. Besides this Specification, provisions in the current national special standards shall also be followed in the strengthening and restoration for concrete structure and masonry structure in special environment (such as corrosion and high temperature etc.) by way of sprayed concrete technology.
Contents of CECS 161: 2004
Foreword I 1 General Provisions 1 2 Terms and Symbols 1 2.1 Term 1 2.2 Symbols 1 3 Materials 2 3.1 Raw Materials for Sprayed Concrete 2 3.2 Admixtures for the Sprayed Concrete 4 3.3 Short Fibre Materials for the Sprayed Concrete 4 3.4 Mix Design of the Sprayed Concrete 5 4 Construction Machines and Tools 5 5 Strengthening Design for the Sprayed Concrete 6 5.1 General Requirements 6 5.2 Strengthening Calculation 7 5.3 Structural Requirements 9 6 Construction Technology 14 6.1 Construction Preparation 14 6.2 Spraying Operation 15 6.3 Safety Measures 16 7 Quality Inspection & Acceptance 17 7.1 Quality Inspection 17 7.2 Acceptance of Works 19 Appendix A Preparation of Standard Test Block for Compressive Strength of Sprayed Concrete 21 Explanation of Wording in This Specification 22
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: TransForyou Co., Ltd. 2008-2040
 
 
Keywords:
CECS 161: 2004, CECS/T 161: 2004, CECST 161: 2004, CECS161:2004, CECS/T161:2004, CECST161:2004,