DL/T 466-2004   Guide for type selection for pulverizers and pulverizing systems of power station (English Version)
Standard No.: DL/T 466-2004 Status:superseded remind me the status change

Email:

Language:English File Format:PDF
Word Count: 22000 words Price(USD):320.0 remind me the price change

Email:

Implemented on:2004-6-1 Delivery: via email in 1 business day
,,
Standard No.: DL/T 466-2004
English Name: Guide for type selection for pulverizers and pulverizing systems of power station
Chinese Name: 电站磨煤机及制粉系统选型导则
Chinese Classification: F22    Electric power system equipment installation testing
Professional Classification: DL    Professional Standard - Electricity
Issued by: NDRC
Issued on: 2004-3-9
Implemented on: 2004-6-1
Status: superseded
Superseded by:DL/T 466-2017
Superseded on:2018-3-1
Superseding:DL/T 466-1992 Guide for Type Selection for Pulverizers and Pulverizing Systems of Power Station
Language: English
File Format: PDF
Word Count: 22000 words
Price(USD): 320.0
Delivery: via email in 1 business day
This standard specifies the guiding rules for the type and parameter selection of pulverizer and pulverizing system in power stations. This standard is applicable to high, medium and low speed pulverizers and corresponding pulverizing systems used in power stations. This Standard is applicable to condensing thermal power plants with a unit capacity of 100MW~ 600MW and thermal units with a unit capacity of 50MW or above. It may apply the units of over 600MW by reference.
1 Scope 1 2 Normative References 1 3 Terms and Definitions 2 4 Characters of Coal and Pulverized Coal 6 4.1 Gridability of Coal 6 4.2 Abrasiveness of Coal 7 4.3 Coal Caking Character 8 4.4 Explosivity of Pulverized Coal 8 4.5 Fineness of Pulverized Coal 9 4.6 Moisture of Coal and Pulverized Coal 11 4.7 Ignitability and Burn-out of Pulverized Coal 12 5 Initial Design Data 13 6 Type and Performance of Pulverizers 14 6.1 Low Speed Pulverizer 14 6.2 Medium Speed Pulverizer 17 6.3 High Speed Pulverizer 23 6.4 Comprehensive Comparison of Performances of Pulverizers 27 7 Type and Performance of Pulverizing Systems 3 7.1 Hot-Blast Pulverizing System of Intermediate-Warehoused Steel Ball Pulverizer 3 7.2 Exhausted-Air-Feeding Pulverizing System of Intermediate-Warehoused Steel Ball Pulverizer 7 7.3 Direct-Firing Pulverizing System of Medium Speed Pulverizer 7 7.4 Direct-Firing System of Double-In Double-Out Steel Ball Pulverizer 9 7.5 Direct-Firing Pulverizing System of Fan Pulverizer 10 7.6 Smoke Drying Of Intermediate-Warehoused Hot Boiler, Hot Blast Feeding Closed-And Open-Systems 12 7.7 Semi-Direct-Firing Pulverizing System Of Double-In Double-Out Steel Ball Pulverizer 14 7.8 Comprehensive Comparison of Various Pulverizing Systems in Performances 14 8 Explosion-Proof Design of Pulverizing System 16 9 Selection of Pulverizer and Pulverizing System 18 9.1 Selection Principles 18 9.2 Pulverizer and Pulverizing System Type Recommended For Different Coal Properties 18 Appendix A (Informative) Determination of Maximum Molecular Water and Maximum Capillary Water 22 Appendix B (Informative) Determination of External Friction Angle, Internal Friction Angle and Collective Angle 23 Appendix C (Informative) Fire Coal Explosivity Index of Power Plants in China 25 Appendix D (Normative) Conversion Of Basis In Coal Analysis 27 Appendix E (Informative) Parameter Of Steel Ball Pulverizer Series 29 Appendix F (Informative) Parameter Of Double-In Double-Out Steel Ball Pulverizer Series 30 Appendix G (Informative) Parameter Of RP (HP) Pulverizer Series 32 Appendix H (Informative) Parameter Of MPS Pulverizer Series 33 Appendix I (Informative) Performance Parameter Of MP And ZGM Pulverizer Series 34 Appendix J (Informative) Parameter Of E Pulverizer Series 37 Appendix K (Informative) Parameter Of Fan Pulverizer Series 1
Referred in DL/T 466-2004:
* GB/T 211-2007 Determination of total moisture in coal
* GB 212-19
* GB/T 213-2008 Determination of calorific value of coal
* GB 474-2008 Method for preparation of coal sample
* GB 475-2008 Method for manual sampling of commercial coal
* GB/T 476-2008 Determination of carbon and hydrogen in coal
* GB 2565-19
* GB/T 15458-2006 Determination of abrasion index of coal
* DL 465-
* DL/T 831-2003
* DL 5000-2000 Technical code for designing fossil fuel power plants
* DL/T5121-2000 Technical Technical Code for Design of Thermal Power Plant Air & Flue Gas Du
* DL/T 5145-2012 Technical Code for Design and Calculation of Pulverized Coal Preparation System of Fossil-Fired Power Plant
* SD 328-1989
DL/T 466-2004 is referred in:
* DL/T 5203-2005 Technical Code for Explosion Prevention Design of Coal and Pulveri
Code of China
Standard
DL/T 466-2004  Guide for type selection for pulverizers and pulverizing systems of power station (English Version)
Standard No.DL/T 466-2004
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count22000 words
Price(USD)320.0
Implemented on2004-6-1
Deliveryvia email in 1 business day
Detail of DL/T 466-2004
Standard No.
DL/T 466-2004
English Name
Guide for type selection for pulverizers and pulverizing systems of power station
Chinese Name
电站磨煤机及制粉系统选型导则
Chinese Classification
F22
Professional Classification
DL
ICS Classification
Issued by
NDRC
Issued on
2004-3-9
Implemented on
2004-6-1
Status
superseded
Superseded by
DL/T 466-2017
Superseded on
2018-3-1
Abolished on
Superseding
DL/T 466-1992 Guide for Type Selection for Pulverizers and Pulverizing Systems of Power Station
Language
English
File Format
PDF
Word Count
22000 words
Price(USD)
320.0
Keywords
DL/T 466-2004, DL 466-2004, DLT 466-2004, DL/T466-2004, DL/T 466, DL/T466, DL466-2004, DL 466, DL466, DLT466-2004, DLT 466, DLT466
Introduction of DL/T 466-2004
This standard specifies the guiding rules for the type and parameter selection of pulverizer and pulverizing system in power stations. This standard is applicable to high, medium and low speed pulverizers and corresponding pulverizing systems used in power stations. This Standard is applicable to condensing thermal power plants with a unit capacity of 100MW~ 600MW and thermal units with a unit capacity of 50MW or above. It may apply the units of over 600MW by reference.
Contents of DL/T 466-2004
1 Scope 1 2 Normative References 1 3 Terms and Definitions 2 4 Characters of Coal and Pulverized Coal 6 4.1 Gridability of Coal 6 4.2 Abrasiveness of Coal 7 4.3 Coal Caking Character 8 4.4 Explosivity of Pulverized Coal 8 4.5 Fineness of Pulverized Coal 9 4.6 Moisture of Coal and Pulverized Coal 11 4.7 Ignitability and Burn-out of Pulverized Coal 12 5 Initial Design Data 13 6 Type and Performance of Pulverizers 14 6.1 Low Speed Pulverizer 14 6.2 Medium Speed Pulverizer 17 6.3 High Speed Pulverizer 23 6.4 Comprehensive Comparison of Performances of Pulverizers 27 7 Type and Performance of Pulverizing Systems 3 7.1 Hot-Blast Pulverizing System of Intermediate-Warehoused Steel Ball Pulverizer 3 7.2 Exhausted-Air-Feeding Pulverizing System of Intermediate-Warehoused Steel Ball Pulverizer 7 7.3 Direct-Firing Pulverizing System of Medium Speed Pulverizer 7 7.4 Direct-Firing System of Double-In Double-Out Steel Ball Pulverizer 9 7.5 Direct-Firing Pulverizing System of Fan Pulverizer 10 7.6 Smoke Drying Of Intermediate-Warehoused Hot Boiler, Hot Blast Feeding Closed-And Open-Systems 12 7.7 Semi-Direct-Firing Pulverizing System Of Double-In Double-Out Steel Ball Pulverizer 14 7.8 Comprehensive Comparison of Various Pulverizing Systems in Performances 14 8 Explosion-Proof Design of Pulverizing System 16 9 Selection of Pulverizer and Pulverizing System 18 9.1 Selection Principles 18 9.2 Pulverizer and Pulverizing System Type Recommended For Different Coal Properties 18 Appendix A (Informative) Determination of Maximum Molecular Water and Maximum Capillary Water 22 Appendix B (Informative) Determination of External Friction Angle, Internal Friction Angle and Collective Angle 23 Appendix C (Informative) Fire Coal Explosivity Index of Power Plants in China 25 Appendix D (Normative) Conversion Of Basis In Coal Analysis 27 Appendix E (Informative) Parameter Of Steel Ball Pulverizer Series 29 Appendix F (Informative) Parameter Of Double-In Double-Out Steel Ball Pulverizer Series 30 Appendix G (Informative) Parameter Of RP (HP) Pulverizer Series 32 Appendix H (Informative) Parameter Of MPS Pulverizer Series 33 Appendix I (Informative) Performance Parameter Of MP And ZGM Pulverizer Series 34 Appendix J (Informative) Parameter Of E Pulverizer Series 37 Appendix K (Informative) Parameter Of Fan Pulverizer Series 1