2025-12-26 216.73.216.41
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB 11417.2-2025
GB 11417.2-2025   Ophthalmic optics—Contact lenses—Part 2: Rigid contact lenses (English Version)
Standard No.: GB 11417.2-2025 Status:to be valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 9500 words Translation Price(USD):285.0 remind me the price change

Email:

Implemented on:2028-11-1 Delivery: via email in 1~3 business day

→ → →

,,2028-11-1,04DD4ABBD2BC13F41762263303249
Standard No.: GB 11417.2-2025
English Name: Ophthalmic optics—Contact lenses—Part 2: Rigid contact lenses
Chinese Name: 眼科光学 接触镜 第2部分:硬性接触镜
Professional Classification: GB    National Standard
Source Content Issued by: SAMR; SAC
Issued on: 2025-10-31
Implemented on: 2028-11-1
Status: to be valid
Superseding:GB 11417.2-2012 Ophthalmic optics—Contact lenses—Part 2:Rigid contact lenses specification
GB 11417.2-2012/XG1-2022 Ophthalmic optics—Contact lenses—Part 2:Rigid contact lenses specification, includes Amendment 1
Target Language: English
File Format: PDF
Word Count: 9500 words
Translation Price(USD): 285.0
Delivery: via email in 1~3 business day
GB 11417.2-2025 Ophthalmic optics—Contact lenses—Part 2: Rigid contact lenses English, Anglais, Englisch, Inglés, えいご This is a draft translation for reference among interesting stakeholders. The finalized translation (passing through draft translation, self-check, revision and verification) will be delivered upon being ordered. ICS 13.220.01 CCS C 81 National Standard of the People's Republic of China ‌GB 11417.2-2025 Replaces GB 11417.2-2012 Ophthalmic optics - Contact lenses - Part 2: Rigid contact lenses 眼科光学 接触镜 第2部分:硬性接触镜 Issue date: 2025-10-31 Implementation date: 2026-11-01 Issued by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China the Standardization Administration of the People's Republic of China Contents Foreword‌ ‌Introduction‌ 1 Scope 2 Normative References 3 Terms and Definitions 4 Requirements 5 Test Methods 6 Labels, Markings, and Accompanying Documents Appendix A (Normative) List of Test Method Applicable Documents for Rigid Contact Lenses References 1 Scope This document specifies the requirements, labeling, marking, and accompanying documents for rigid contact lenses, and describes the test methods. This document applies to rigid contact lenses. 2 Normative References The contents of the following documents constitute essential provisions of this document. For normative references with a specified date, only the version corresponding to that date applies to this document; for normative references without a specified date, the latest version (including all amendments) applies to this document. GB/T 11417.1: Ophthalmic Optics — Contact Lenses — Part 1: Vocabulary, Classification, and Recommended Marking Specifications GB/T 11417.4: Ophthalmic Optics — Contact Lenses — Part 4: Standard Salt Solution for Testing GB/T 11417.5: Ophthalmic Optics — Contact Lenses — Part 5: Optical Performance Test Methods GB/T 11417.6: Ophthalmic Optics — Contact Lenses — Part 6: Mechanical Performance Test Methods GB/T 11417.7: Ophthalmic Optics — Contact Lenses — Part 7: Physical and Chemical Performance Test Methods GB/T 11417.8: Ophthalmic Optics — Contact Lenses — Part 8: Determination of Shelf Life GB/T 11417.9: Ophthalmic Optics — Contact Lenses — Part 9: In Vitro Test for Ultraviolet and Visible Light Radiation Aging GB/T 16886.1: Biological Evaluation of Medical Devices — Part 1: Evaluation and Testing Within a Risk Management Process GB/T 19973.1: Sterilization of Healthcare Products — Microbiological Methods — Part 1: Determination of Total Microbial Count on Products GB/T 28538: Ophthalmic Optics — Contact Lenses and Contact Lens Care Products — Rabbit Eye Compatibility Study Test GB/T 28539: Ophthalmic Optics — Contact Lenses and Contact Lens Care Products — Determination of Preservative Intake and Release YY/T 0466.1: Medical Devices — Symbols for Information Provided by Manufacturers — Part 1: General Requirements Pharmacopoeia of the People’s Republic of China, Part Four 3 Terms and Definitions The terms and definitions defined in GB/T 11417.1 apply to this document. 4 Requirements 4.1 General Requirements In addition to the requirements of 4.2 to 4.8, if the manufacturer explicitly states that there are other special designs or additional performance features, detailed descriptions should be provided, along with applicable requirements and test methods. 4.2 Optical Performance 4.2.1 General Provisions For contact lenses that do not have optical performance for special medical purposes, if there are clear descriptions in the accompanying documents and markings, the requirements of 4.2.2 to 4.2.4 for optical performance may not apply. 4.2.2 Posterior Vertex Power, Cylinder Power, and Cylinder Axis The nominal values of the posterior vertex power, cylinder power, and cylinder axis (if any) of the contact lens should be marked on the small - package container. The tolerance of the nominal values should comply with the provisions of Table 1. Table 1 Requirements for Posterior Vertex Power, Cylinder Power, and Cylinder Axis 4.3 Dimensional Requirements 4.3.2 Microholes, Bevels, and Displacement Dimensions If there are microholes, bevels, or displacement, their geometric dimensions should be marked on the small - package container. The relative deviation between the measured value and the nominal value should not exceed 10%. 4.3.3 Maximum Deviation of Optical Center The maximum deviation of the optical center for scleral contact lenses is 0.50 mm. 4.4 Contact Lens Materials 4.4.1 Material Description The manufacturer should indicate that the contact lens material is classified and marked in accordance with the requirements of GB/T 11417.1, and provide the main chemical molecular structure of the material. For colored contact lenses, the name, category, and ratio of the dyes or pigments used should be indicated, along with the basis for their safe and reliable application. 4.4.2 Material Physical Performance 4.4.2.1 Refractive Index The nominal value of the refractive index of the contact lens material should be given in the accompanying documents, with a tolerance of ±0.002. 4.4.2.2 Oxygen Permeability The nominal value of the oxygen permeability coefficient and the nominal value of the oxygen permeability of typical application contact lenses should be given in the accompanying documents. The relative tolerance of the nominal value of the oxygen permeability coefficient should be ±20%, and the relative tolerance of the nominal value of the oxygen permeability should be -20% (the upper limit is not counted). 4.4.2.3 Material Hardness The nominal value of the hardness of the contact lens material should be given in the accompanying documents in terms of Shore D hardness, with a tolerance of ±5. 4.4.2.4 Contact Angle The nominal value of the static contact angle of the contact lens material should be given in the accompanying documents, with a relative tolerance of ±20%. 4.4.2.5 Mechanical Performance The bending deformation and load at the time of contact lens fracture (if not fractured, the load at 70% deformation can be given), the load at 30% deformation, and the corresponding experimental standard deviation should be given in the accompanying documents, and verified in accordance with the test methods specified in Chapter 5. 4.4.3 Material Chemical Performance 4.4.3.1 Extraction
Code of China
Standard
GB 11417.2-2025  Ophthalmic optics—Contact lenses—Part 2: Rigid contact lenses (English Version)
Standard No.GB 11417.2-2025
Statusto be valid
LanguageEnglish
File FormatPDF
Word Count9500 words
Price(USD)285.0
Implemented on2028-11-1
Deliveryvia email in 1~3 business day
Detail of GB 11417.2-2025
Standard No.
GB 11417.2-2025
English Name
Ophthalmic optics—Contact lenses—Part 2: Rigid contact lenses
Chinese Name
眼科光学 接触镜 第2部分:硬性接触镜
Chinese Classification
Professional Classification
GB
ICS Classification
Issued by
SAMR; SAC
Issued on
2025-10-31
Implemented on
2028-11-1
Status
to be valid
Superseded by
Superseded on
Abolished on
Superseding
GB 11417.2-2012 Ophthalmic optics—Contact lenses—Part 2:Rigid contact lenses specification
GB 11417.2-2012/XG1-2022 Ophthalmic optics—Contact lenses—Part 2:Rigid contact lenses specification, includes Amendment 1
Language
English
File Format
PDF
Word Count
9500 words
Price(USD)
285.0
Keywords
GB 11417.2-2025, GB/T 11417.2-2025, GBT 11417.2-2025, GB11417.2-2025, GB 11417.2, GB11417.2, GB/T11417.2-2025, GB/T 11417.2, GB/T11417.2, GBT11417.2-2025, GBT 11417.2, GBT11417.2
Introduction of GB 11417.2-2025
GB 11417.2-2025 Ophthalmic optics—Contact lenses—Part 2: Rigid contact lenses English, Anglais, Englisch, Inglés, えいご This is a draft translation for reference among interesting stakeholders. The finalized translation (passing through draft translation, self-check, revision and verification) will be delivered upon being ordered. ICS 13.220.01 CCS C 81 National Standard of the People's Republic of China ‌GB 11417.2-2025 Replaces GB 11417.2-2012 Ophthalmic optics - Contact lenses - Part 2: Rigid contact lenses 眼科光学 接触镜 第2部分:硬性接触镜 Issue date: 2025-10-31 Implementation date: 2026-11-01 Issued by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China the Standardization Administration of the People's Republic of China Contents Foreword‌ ‌Introduction‌ 1 Scope 2 Normative References 3 Terms and Definitions 4 Requirements 5 Test Methods 6 Labels, Markings, and Accompanying Documents Appendix A (Normative) List of Test Method Applicable Documents for Rigid Contact Lenses References 1 Scope This document specifies the requirements, labeling, marking, and accompanying documents for rigid contact lenses, and describes the test methods. This document applies to rigid contact lenses. 2 Normative References The contents of the following documents constitute essential provisions of this document. For normative references with a specified date, only the version corresponding to that date applies to this document; for normative references without a specified date, the latest version (including all amendments) applies to this document. GB/T 11417.1: Ophthalmic Optics — Contact Lenses — Part 1: Vocabulary, Classification, and Recommended Marking Specifications GB/T 11417.4: Ophthalmic Optics — Contact Lenses — Part 4: Standard Salt Solution for Testing GB/T 11417.5: Ophthalmic Optics — Contact Lenses — Part 5: Optical Performance Test Methods GB/T 11417.6: Ophthalmic Optics — Contact Lenses — Part 6: Mechanical Performance Test Methods GB/T 11417.7: Ophthalmic Optics — Contact Lenses — Part 7: Physical and Chemical Performance Test Methods GB/T 11417.8: Ophthalmic Optics — Contact Lenses — Part 8: Determination of Shelf Life GB/T 11417.9: Ophthalmic Optics — Contact Lenses — Part 9: In Vitro Test for Ultraviolet and Visible Light Radiation Aging GB/T 16886.1: Biological Evaluation of Medical Devices — Part 1: Evaluation and Testing Within a Risk Management Process GB/T 19973.1: Sterilization of Healthcare Products — Microbiological Methods — Part 1: Determination of Total Microbial Count on Products GB/T 28538: Ophthalmic Optics — Contact Lenses and Contact Lens Care Products — Rabbit Eye Compatibility Study Test GB/T 28539: Ophthalmic Optics — Contact Lenses and Contact Lens Care Products — Determination of Preservative Intake and Release YY/T 0466.1: Medical Devices — Symbols for Information Provided by Manufacturers — Part 1: General Requirements Pharmacopoeia of the People’s Republic of China, Part Four 3 Terms and Definitions The terms and definitions defined in GB/T 11417.1 apply to this document. 4 Requirements 4.1 General Requirements In addition to the requirements of 4.2 to 4.8, if the manufacturer explicitly states that there are other special designs or additional performance features, detailed descriptions should be provided, along with applicable requirements and test methods. 4.2 Optical Performance 4.2.1 General Provisions For contact lenses that do not have optical performance for special medical purposes, if there are clear descriptions in the accompanying documents and markings, the requirements of 4.2.2 to 4.2.4 for optical performance may not apply. 4.2.2 Posterior Vertex Power, Cylinder Power, and Cylinder Axis The nominal values of the posterior vertex power, cylinder power, and cylinder axis (if any) of the contact lens should be marked on the small - package container. The tolerance of the nominal values should comply with the provisions of Table 1. Table 1 Requirements for Posterior Vertex Power, Cylinder Power, and Cylinder Axis 4.3 Dimensional Requirements 4.3.2 Microholes, Bevels, and Displacement Dimensions If there are microholes, bevels, or displacement, their geometric dimensions should be marked on the small - package container. The relative deviation between the measured value and the nominal value should not exceed 10%. 4.3.3 Maximum Deviation of Optical Center The maximum deviation of the optical center for scleral contact lenses is 0.50 mm. 4.4 Contact Lens Materials 4.4.1 Material Description The manufacturer should indicate that the contact lens material is classified and marked in accordance with the requirements of GB/T 11417.1, and provide the main chemical molecular structure of the material. For colored contact lenses, the name, category, and ratio of the dyes or pigments used should be indicated, along with the basis for their safe and reliable application. 4.4.2 Material Physical Performance 4.4.2.1 Refractive Index The nominal value of the refractive index of the contact lens material should be given in the accompanying documents, with a tolerance of ±0.002. 4.4.2.2 Oxygen Permeability The nominal value of the oxygen permeability coefficient and the nominal value of the oxygen permeability of typical application contact lenses should be given in the accompanying documents. The relative tolerance of the nominal value of the oxygen permeability coefficient should be ±20%, and the relative tolerance of the nominal value of the oxygen permeability should be -20% (the upper limit is not counted). 4.4.2.3 Material Hardness The nominal value of the hardness of the contact lens material should be given in the accompanying documents in terms of Shore D hardness, with a tolerance of ±5. 4.4.2.4 Contact Angle The nominal value of the static contact angle of the contact lens material should be given in the accompanying documents, with a relative tolerance of ±20%. 4.4.2.5 Mechanical Performance The bending deformation and load at the time of contact lens fracture (if not fractured, the load at 70% deformation can be given), the load at 30% deformation, and the corresponding experimental standard deviation should be given in the accompanying documents, and verified in accordance with the test methods specified in Chapter 5. 4.4.3 Material Chemical Performance 4.4.3.1 Extraction
Contents of GB 11417.2-2025
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 11417.2-2025, GB/T 11417.2-2025, GBT 11417.2-2025, GB11417.2-2025, GB 11417.2, GB11417.2, GB/T11417.2-2025, GB/T 11417.2, GB/T11417.2, GBT11417.2-2025, GBT 11417.2, GBT11417.2