2025-12-26 216.73.216.41
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB 12523-2025
GB 12523-2025   Emission standard for construction noise (English Version)
Standard No.: GB 12523-2025 Status:to be valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 3000 words Translation Price(USD):90.0 remind me the price change

Email:

Implemented on:2026-1-1 Delivery: via email in 1~3 business day

→ → →

,,2026-1-1,E7BB38E92E4423E31764727425471
Standard No.: GB 12523-2025
English Name: Emission standard for construction noise
Chinese Name: 建筑施工噪声排放标准
Professional Classification: GB    National Standard
Source Content Issued by: SAMR;SAC
Issued on: 2025-12-02
Implemented on: 2026-1-1
Status: to be valid
Superseding:GB 12523-2011 Emisson standard of environment noise for boundary of construction site
Target Language: English
File Format: PDF
Word Count: 3000 words
Translation Price(USD): 90.0
Delivery: via email in 1~3 business day
GB 12523-2025 Emission standard for construction noise 1 Application scope This standard specifies the emission limits for construction noise around noise-sensitive buildings, as well as the requirements for monitoring and evaluation, implementation and supervision of such noise. This standard applies to the management, evaluation, and control of emission of construction noise, including but not limited to buildings, municipal, telecommunications, transportation, water conservancy, and power constructions. This standard does not apply to the regulation of noise emissions generated during emergency maintenance or rescue operations. 2 Normative references The following normative documents contain provisions which, through reference in this text, constitute provisions of this standard. For dated references, only the edition cited applies. For undated references, the latest edition of the normative document (including any amendments) applies. For other documents that are abolished, revised or revised by new documents, the new ones shall apply to this standard. GB/T 3785.1 Electroacoustics - Sound level meters - Part 1: Specifications GB/T 15173 Electroacoustics - Sound calibrators HJ 706 Technical Specifications for Environmental Noise Monitoring Correction for measured noise level HJ 1402 Technical specification for automatic monitoring of construction noise 3 Terms and definitions For the purposes of this standard, the following term and definition apply: 3.1 construction construction of various types of building structures, civil engineering works, and their ancillary facilities, as well as the installation of supporting lines, pipelines and equipment, later-stage activities such as architectural decoration and finishing, building demolition, site preparation, and other construction-related operations, excluding interior decoration activities in buildings that have already been completed and delivered for use 3.2 construction noise noise generated during construction that interferes with the surrounding living environment 3.3 A-weighted sound pressure level sound pressure level measured with A-weighted network, expressed by LA, in dB(A) 3.4 equivalent continuous A-weighted sound pressure level equivalent sound level for short, energy average of the A-weighted sound level over a specified measurement time T, denoted as LAeq,T (abbreviated as Lcq) and expressed in dB(A) Unless otherwise specified, all noise values in this standard refer to the equivalent sound level. According to the definition, the equivalent sound level is expressed as: where, Leq - equivalent sound level; LA - instantaneous A-weighted sound level at time t; T - specified measurement time period. 3.5 boundary of construction site boundary of construction site, which is either approved by the relevant competent authority or the actual area used during the construction process 3.6 noise-sensitive buildings buildings that require a quiet environment, such as those used for residence, scientific research, medical and health services, cultural education, office use by government agencies and organizations, social welfare, etc. 3.7 maximum sound level highest A-weighted sound level measured within the specified measurement period, denoted as LAmax and expressed in dB(A) 3.8 day-time, night-time according to the Noise Pollution Prevention and Control Law of the People's Republic of China, "night-time" refers to the period from 10:00 p.m. to 6:00 a.m. the following day. Municipal governments with districts or higher-level people's governments may specify different start and end times for night-time within their respective administrative regions, and the night-time duration remains eight hours "Day-time" refers to all periods other than the night-time period. 3.9 background noise noise emitted by all noise sources other than the noise source being measured 3.10 automatic monitoring system of construction noise system that continuously and automatically monitors construction noise in an unattended manner, while performing real-time statistical analysis, transmission, and storage of noise data. It typically consists of one or multiple noise monitoring substations, supporting equipment (such as meteorological data collectors, audio/video capture devices, etc.), and a noise monitoring management platform 4 Noise emission limits 4.1 During construction, the equivalent sound level of noise at the site boundary shall not exceed the emission limits specified in Table 1. Table 1 Noise emission limits for boundary of construction site Unit: dB(A) Day-time Night-time 70 55 4.2 The maximum sound level of night-time noise at the site boundary shall not exceed the limits specified in Table 1 by more than 15 dB(A). 4.3 When noise emission from the source cannot be measured at the site boundary, measurements shall be taken outdoors at noise-sensitive buildings. The emission limits specified in 4.1 and 4.2 shall serve as the basis for evaluation. 4.4 When the site boundary is too close to noise-sensitive buildings and outdoor measurements do not meet the requirements, measurements shall be taken indoors within the noise-sensitive buildings. The corresponding limits specified in 4.1 and 4.2, reduced by 10 dB (A), shall serve as the basis for evaluation.
Contents Foreword I 1 Application scope 2 Normative references 3 Terms and definitions 4 Noise emission limits 5 Monitoring requirements for noise emission 6 Evaluation of measurement results 7 Inplementation and supervision
Referred in GB 12523-2025:
*GB/T 3785.1-2023 Electroacoustics—Sound level meters—Part 1: Specifications
*GB/T 15173-2010 Electroacoustics—Sound calibrators
*HJ 706-2014 Technical specifications for environmental noise monitoring conrrection for measured noise level
*HJ 1402-2024 Technical specification for automatic monitoring of construction noise
Code of China
Standard
GB 12523-2025  Emission standard for construction noise (English Version)
Standard No.GB 12523-2025
Statusto be valid
LanguageEnglish
File FormatPDF
Word Count3000 words
Price(USD)90.0
Implemented on2026-1-1
Deliveryvia email in 1~3 business day
Detail of GB 12523-2025
Standard No.
GB 12523-2025
English Name
Emission standard for construction noise
Chinese Name
建筑施工噪声排放标准
Chinese Classification
Professional Classification
GB
ICS Classification
Issued by
SAMR;SAC
Issued on
2025-12-02
Implemented on
2026-1-1
Status
to be valid
Superseded by
Superseded on
Abolished on
Superseding
GB 12523-2011 Emisson standard of environment noise for boundary of construction site
Language
English
File Format
PDF
Word Count
3000 words
Price(USD)
90.0
Keywords
GB 12523-2025, GB/T 12523-2025, GBT 12523-2025, GB12523-2025, GB 12523, GB12523, GB/T12523-2025, GB/T 12523, GB/T12523, GBT12523-2025, GBT 12523, GBT12523
Introduction of GB 12523-2025
GB 12523-2025 Emission standard for construction noise 1 Application scope This standard specifies the emission limits for construction noise around noise-sensitive buildings, as well as the requirements for monitoring and evaluation, implementation and supervision of such noise. This standard applies to the management, evaluation, and control of emission of construction noise, including but not limited to buildings, municipal, telecommunications, transportation, water conservancy, and power constructions. This standard does not apply to the regulation of noise emissions generated during emergency maintenance or rescue operations. 2 Normative references The following normative documents contain provisions which, through reference in this text, constitute provisions of this standard. For dated references, only the edition cited applies. For undated references, the latest edition of the normative document (including any amendments) applies. For other documents that are abolished, revised or revised by new documents, the new ones shall apply to this standard. GB/T 3785.1 Electroacoustics - Sound level meters - Part 1: Specifications GB/T 15173 Electroacoustics - Sound calibrators HJ 706 Technical Specifications for Environmental Noise Monitoring Correction for measured noise level HJ 1402 Technical specification for automatic monitoring of construction noise 3 Terms and definitions For the purposes of this standard, the following term and definition apply: 3.1 construction construction of various types of building structures, civil engineering works, and their ancillary facilities, as well as the installation of supporting lines, pipelines and equipment, later-stage activities such as architectural decoration and finishing, building demolition, site preparation, and other construction-related operations, excluding interior decoration activities in buildings that have already been completed and delivered for use 3.2 construction noise noise generated during construction that interferes with the surrounding living environment 3.3 A-weighted sound pressure level sound pressure level measured with A-weighted network, expressed by LA, in dB(A) 3.4 equivalent continuous A-weighted sound pressure level equivalent sound level for short, energy average of the A-weighted sound level over a specified measurement time T, denoted as LAeq,T (abbreviated as Lcq) and expressed in dB(A) Unless otherwise specified, all noise values in this standard refer to the equivalent sound level. According to the definition, the equivalent sound level is expressed as: where, Leq - equivalent sound level; LA - instantaneous A-weighted sound level at time t; T - specified measurement time period. 3.5 boundary of construction site boundary of construction site, which is either approved by the relevant competent authority or the actual area used during the construction process 3.6 noise-sensitive buildings buildings that require a quiet environment, such as those used for residence, scientific research, medical and health services, cultural education, office use by government agencies and organizations, social welfare, etc. 3.7 maximum sound level highest A-weighted sound level measured within the specified measurement period, denoted as LAmax and expressed in dB(A) 3.8 day-time, night-time according to the Noise Pollution Prevention and Control Law of the People's Republic of China, "night-time" refers to the period from 10:00 p.m. to 6:00 a.m. the following day. Municipal governments with districts or higher-level people's governments may specify different start and end times for night-time within their respective administrative regions, and the night-time duration remains eight hours "Day-time" refers to all periods other than the night-time period. 3.9 background noise noise emitted by all noise sources other than the noise source being measured 3.10 automatic monitoring system of construction noise system that continuously and automatically monitors construction noise in an unattended manner, while performing real-time statistical analysis, transmission, and storage of noise data. It typically consists of one or multiple noise monitoring substations, supporting equipment (such as meteorological data collectors, audio/video capture devices, etc.), and a noise monitoring management platform 4 Noise emission limits 4.1 During construction, the equivalent sound level of noise at the site boundary shall not exceed the emission limits specified in Table 1. Table 1 Noise emission limits for boundary of construction site Unit: dB(A) Day-time Night-time 70 55 4.2 The maximum sound level of night-time noise at the site boundary shall not exceed the limits specified in Table 1 by more than 15 dB(A). 4.3 When noise emission from the source cannot be measured at the site boundary, measurements shall be taken outdoors at noise-sensitive buildings. The emission limits specified in 4.1 and 4.2 shall serve as the basis for evaluation. 4.4 When the site boundary is too close to noise-sensitive buildings and outdoor measurements do not meet the requirements, measurements shall be taken indoors within the noise-sensitive buildings. The corresponding limits specified in 4.1 and 4.2, reduced by 10 dB (A), shall serve as the basis for evaluation.
Contents of GB 12523-2025
Contents Foreword I 1 Application scope 2 Normative references 3 Terms and definitions 4 Noise emission limits 5 Monitoring requirements for noise emission 6 Evaluation of measurement results 7 Inplementation and supervision
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 12523-2025, GB/T 12523-2025, GBT 12523-2025, GB12523-2025, GB 12523, GB12523, GB/T12523-2025, GB/T 12523, GB/T12523, GBT12523-2025, GBT 12523, GBT12523