GB 15322.1-2026   Combustible gas detectors—Part 1: Point-type combustible gas detectors for industrial and commercial use (English)
Standard No.: GB 15322.1-2026 Status:to be valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 24500 words Translation Price(USD):735.0 remind me the price change

Email:

Implemented on:2027-8-1 Delivery: via email in 1~8 business day

→ → →

,,2027-8-1,EBCB7C2E5F26459F1770280633268
Standard No.: GB 15322.1-2026
English Name: Combustible gas detectors—Part 1: Point-type combustible gas detectors for industrial and commercial use
Chinese Name: 可燃气体探测器 第1部分:工业及商业用途点型可燃气体探测器
Professional Classification: GB    National Standard
Source Content Issued by: SAMR;SAC
Issued on: 2026-01-28
Implemented on: 2027-8-1
Status: to be valid
Superseding:GB 15322.1-2019 Combustible gas detectors—Part 1: Point-type combustible gas detectors for industrial and commercial use
Target Language: English
File Format: PDF
Word Count: 24500 words
Translation Price(USD): 735.0
Delivery: via email in 1~8 business day
GB 15322.1-2026 Combustible gas detectors—Part 1: Point-type combustible gas detectors for industrial and commercial use English, Anglais, Englisch, Inglés, えいご This is a draft translation for reference among interesting stakeholders. The finalized translation (passing through draft translation, self-check, revision and verification) will be delivered upon being ordered. ICS CCS National Standard of the People's Republic of China ‌GB 15322.1-2026 Combustible gas detectors - Part 1: Point-type combustible gas detectors for industrial and commercial use 可燃气体探测器 第1部分:工业及商业用途点型可燃气体探测器 Issue date: 2026-01-28 Implementation date: 2027-02-01 Issued by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China the Standardization Administration of the People's Republic of China Contents Foreword Introduction 1 Scope 2 Normative References 3 Terms and Definitions 4 Classification and Naming 5 Requirements 5.1 General Requirements 5.2 Enclosure and Explosion Protection Requirements 5.3 Main Component Performance 5.4 Detection and Alarm Function 5.5 Communication Function 5.6 Historical Event Recording Function 5.7 Alarm Actuation Performance 5.8 Range Indication Deviation 5.9 Response Time 5.10 Orientation 5.11 High Velocity Airflow 5.12 Alarm Performance during Warm-up 5.13 Ignition Prevention Performance 5.14 Sampling Airflow Variation 5.15 Communication Transmission Performance 5.16 Power Supply Parameter Fluctuation Performance 5.17 Battery Capacity 5.18 Insulation Resistance 5.19 Dielectric Strength 5.20 Electromagnetic Compatibility Performance 5.21 Climatic Environment Resistance 5.22 Mechanical Environment Resistance 5.23 Resistance to Gas Interference 5.24 Resistance to Cooking Oil Fume Interference 5.25 Resistance to Poisoning 5.26 Resistance to High Concentration Gas Impact 5.27 Resistance to Ageing 5.28 Longterm Stability 5.29 Low Concentration Carbon Monoxide Response Performance 5.30 Response Performance of Detectors with Multiple Target Gases 6 Test Methods 6.1 General Requirements 6.2 Function Test 6.3 Alarm Actuation Value Test 6.4 Range Indication Deviation Test 6.5 Response Time Test 6.6 Orientation Test 6.7 High Velocity Airflow Test 6.8 Alarm Test during Warmup 6.9 Ignition Prevention Performance Test 6.10 Sampling Airflow Variation Test 6.11 Communication Transmission Performance Test 6.12 Power Supply Parameter Fluctuation Test 6.13 Battery Capacity Test 6.14 Insulation Resistance Test 6.15 Dielectric Strength Test 6.16 Electrostatic Discharge Immunity Test 6.17 Radiated RadioFrequency Electromagnetic Field Immunity Test 6.18 Electrical Fast Transient/Burst Immunity Test 6.19 Surge (Impact) Immunity Test 6.20 Immunity to Conducted Disturbances Induced by RadioFrequency Fields Test 6.21 High Temperature (Operating) Test 6.22 Low Temperature (Operating) Test 6.23 Damp Heat Steady State (Operating) Test 6.24 Salt Spray Test 6.25 Damp Heat Cyclic (Operating) Test 6.26 Sulfur Dioxide (SO₂) Corrosion (Durability) Test 6.27 Vibration (Sinusoidal) (Operating) Test 6.28 Drop Test 6.29 Resistance to Gas Interference Test 6.30 Resistance to Cooking Oil Fume Interference Test 6.31 Resistance to Poisoning Test 6.32 Resistance to High Concentration Gas Impact Test 6.33 Resistance to Ageing Test 6.34 Longterm Stability Test 6.35 Low Concentration Carbon Monoxide Response Performance Test 6.36 MultiTarget Gas Response Performance Test 7 Inspection Rules 7.1 Factory Inspection 7.2 Type Inspection 7.3 Inservice Inspection 8 Marking and Packaging 8.1 Product Marking 8.2 Quality Inspection Marking 8.3 Packaging Annex A (Informative) Guide for application places of point type combustible gas detectors for industrial and commercial use A.1 Industrial Detectors A.2 Commercial Detectors A.3 Pipeline and Well Detectors Annex B (Normative) Model designation rules for combustible gas detector products B.1 Designation Principles B.2 Designation Method Annex C (Normative) Enclosure flammability performance test C.1 General C.2 Test C.3 Requirements Annex D (Normative) Reading device for historical event records of combustible gas detectors D.1 General Requirements D.2 Physical Characteristics D.3 Communication Protocol Annex E (Normative) Test equipment for resistance to cooking oil fume interference E.1 Test Equipment E.2 Technical Parameters Annex F (Normative) Test equipment and test methods for combustible gas detectors F.1 Test Equipment F.2 Test Method for Measuring Alarm Actuation Value F.3 Test Method for Testing Interference Resistance of Specimens Using Liquid Reagents F.4 Test Method for Testing MultiTarget Gas Response Performance Using Liquid Reagents Combustible gas detectors – Part 1: Point type combustible gas detectors for industrial and commercial use 1 Scope This document defines the terms and definitions for point type combustible gas detectors for industrial and commercial use, specifies classification and naming, requirements, inspection rules, and marking and packaging, and describes the corresponding test methods. This document applies to the design, manufacture and inspection of point type combustible gas detector (hereinafter referred to as "detector") products used in industrial and commercial premises. 2 Normative References The contents of the following documents constitute essential provisions of this document through normative reference. For dated references, only the edition cited applies. For undated references, the latest edition (including all amendments) applies. GB/T 3836.1 Explosive atmospheres — Part 1: Equipment — General requirements GB/T 4208-2017 Degrees of protection provided by enclosure (IP code) GB/T 9969 General principles for preparation of instructions for use of industrial products GB 12978 Inspection rules for fire electronic products GB/T 16838 Environmental test methods and severities for fire electronic products GB/T 17626.2 Electromagnetic compatibility — Testing and measurement techniques — Electrostatic discharge immunity test GB/T 17626.3 Electromagnetic compatibility — Testing and measurement techniques — Part 3: Radiated, radiofrequency, electromagnetic field immunity test GB/T 17626.4 Electromagnetic compatibility — Testing and measurement techniques — Electrical fast transient/burst immunity test GB/T 17626.5 Electromagnetic compatibility — Testing and measurement techniques — Surge (impact) immunity test GB/T 17626.6 Electromagnetic compatibility — Testing and measurement techniques — Immunity to conducted disturbances induced by radiofrequency fields 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 lower explosive limit; LEL Under standard atmospheric conditions, the minimum concentration of a combustible gas or vapour in air that will explode. 3.2 monitoring condition The state of a detector after it has been powered on and is operating normally, without any combustible gas alarm, fault, selftest, sensor endoflife, etc., occurring. 3.3 industrial detectors Detectors installed in industrial sites where various types of combustible gases and volatile combustible liquids are stored, transported, used or produced, for the purpose of realtime monitoring of the concentration of combustible gases and vapours in the area. 3.4 commercial detectors Detectors installed in various public and commercial premises other than residential environments such as houses and apartments, for the purpose of realtime monitoring of the concentration of methane, propane and carbon monoxide in the area. 3.5 industrial and commercial detectors Detectors that have both the functions of industrial detectors and commercial detectors, meeting the performance requirements for both industrial and commercial premises. 3.6 pipeline and well detectors Detectors installed in closed environments such as underground pipelines and shafts where there is a risk of combustible gas accumulation, for the purpose of periodic monitoring of the concentration of combustible gases in the area. 3.7 systembased detectors Industrial or commercial detectors that have their own operating status indication function and, after establishing communication with control and indicating equipment such as a combustible gas alarm control unit via wired or wireless communication means, can realise the functions of a combustible gas detection and alarm system. 3.8 standalone detectors Industrial or commercial detectors that can be used independently at the installation site, having functions such as operating status indication, measured concentration display, audible signal output, historical event record storage, and control activation of field actuators. 4 Classification and naming 4.1 Detectors are classified according to the applicable location as: a)Industrial detectors; b) Commercial detectors; c) Industrial and commercial detectors; d) Pipeline and well detectors. NOTE: Typical application places for each type of detector product are given in Annex A. 4.2 Detectors are classified according to the sampling method as: a)Free diffusion detectors; b) Active suction detectors. 4.3 Industrial detectors, commercial detectors, and industrial and commercial detectors are classified according to the mode of operation as: a)Systembased detectors; b) Standalone detectors. 4.4 Industrial detectors are classified according to the measurement range as: a)Detectors with a measurement range from 3% LEL to 100% LEL; b) Detectors with a measurement range below 3% LEL (including detectors for carbon monoxide). 4.5 Industrial detectors are classified according to the use environment as: a)Detectors for indoor use; b) Detectors for outdoor use. 5 Requirements 5.1 General requirements 5.1.1 Detectors shall meet the requirements of this clause and shall be tested in accordance with Clause 6 to confirm conformity with the requirements of this clause. 5.1.2 The model designation of detectors shall comply with Annex B. 5.2 Enclosure and explosion protection requirements 5.2.1 The surface of detectors shall be free from corrosion, coating peeling and blistering, and free from obvious scratches, cracks, burrs and other mechanical damage. Fastened parts shall be free from loosening.
Code of China
Standard
GB 15322.1-2026  Combustible gas detectors—Part 1: Point-type combustible gas detectors for industrial and commercial use (English)
Standard No.GB 15322.1-2026
Statusto be valid
LanguageEnglish
File FormatPDF
Word Count24500 words
Translation Price(USD)735.0
Implemented on2027-8-1
Deliveryvia email in 1~8 business day
Detail of GB 15322.1-2026
Standard No.
GB 15322.1-2026
English Name
Combustible gas detectors—Part 1: Point-type combustible gas detectors for industrial and commercial use
Chinese Name
可燃气体探测器 第1部分:工业及商业用途点型可燃气体探测器
Chinese Classification
Professional Classification
GB
ICS Classification
Issued by
SAMR;SAC
Issued on
2026-01-28
Implemented on
2027-8-1
Status
to be valid
Superseded by
Superseded on
Abolished on
Superseding
GB 15322.1-2019 Combustible gas detectors—Part 1: Point-type combustible gas detectors for industrial and commercial use
Language
English
File Format
PDF
Word Count
24500 words
Translation Price(USD)
735.0
Keywords
GB 15322.1-2026, GB/T 15322.1-2026, GBT 15322.1-2026, GB15322.1-2026, GB 15322.1, GB15322.1, GB/T15322.1-2026, GB/T 15322.1, GB/T15322.1, GBT15322.1-2026, GBT 15322.1, GBT15322.1
Introduction of GB 15322.1-2026
GB 15322.1-2026 Combustible gas detectors—Part 1: Point-type combustible gas detectors for industrial and commercial use English, Anglais, Englisch, Inglés, えいご This is a draft translation for reference among interesting stakeholders. The finalized translation (passing through draft translation, self-check, revision and verification) will be delivered upon being ordered. ICS CCS National Standard of the People's Republic of China ‌GB 15322.1-2026 Combustible gas detectors - Part 1: Point-type combustible gas detectors for industrial and commercial use 可燃气体探测器 第1部分:工业及商业用途点型可燃气体探测器 Issue date: 2026-01-28 Implementation date: 2027-02-01 Issued by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China the Standardization Administration of the People's Republic of China Contents Foreword Introduction 1 Scope 2 Normative References 3 Terms and Definitions 4 Classification and Naming 5 Requirements 5.1 General Requirements 5.2 Enclosure and Explosion Protection Requirements 5.3 Main Component Performance 5.4 Detection and Alarm Function 5.5 Communication Function 5.6 Historical Event Recording Function 5.7 Alarm Actuation Performance 5.8 Range Indication Deviation 5.9 Response Time 5.10 Orientation 5.11 High Velocity Airflow 5.12 Alarm Performance during Warm-up 5.13 Ignition Prevention Performance 5.14 Sampling Airflow Variation 5.15 Communication Transmission Performance 5.16 Power Supply Parameter Fluctuation Performance 5.17 Battery Capacity 5.18 Insulation Resistance 5.19 Dielectric Strength 5.20 Electromagnetic Compatibility Performance 5.21 Climatic Environment Resistance 5.22 Mechanical Environment Resistance 5.23 Resistance to Gas Interference 5.24 Resistance to Cooking Oil Fume Interference 5.25 Resistance to Poisoning 5.26 Resistance to High Concentration Gas Impact 5.27 Resistance to Ageing 5.28 Longterm Stability 5.29 Low Concentration Carbon Monoxide Response Performance 5.30 Response Performance of Detectors with Multiple Target Gases 6 Test Methods 6.1 General Requirements 6.2 Function Test 6.3 Alarm Actuation Value Test 6.4 Range Indication Deviation Test 6.5 Response Time Test 6.6 Orientation Test 6.7 High Velocity Airflow Test 6.8 Alarm Test during Warmup 6.9 Ignition Prevention Performance Test 6.10 Sampling Airflow Variation Test 6.11 Communication Transmission Performance Test 6.12 Power Supply Parameter Fluctuation Test 6.13 Battery Capacity Test 6.14 Insulation Resistance Test 6.15 Dielectric Strength Test 6.16 Electrostatic Discharge Immunity Test 6.17 Radiated RadioFrequency Electromagnetic Field Immunity Test 6.18 Electrical Fast Transient/Burst Immunity Test 6.19 Surge (Impact) Immunity Test 6.20 Immunity to Conducted Disturbances Induced by RadioFrequency Fields Test 6.21 High Temperature (Operating) Test 6.22 Low Temperature (Operating) Test 6.23 Damp Heat Steady State (Operating) Test 6.24 Salt Spray Test 6.25 Damp Heat Cyclic (Operating) Test 6.26 Sulfur Dioxide (SO₂) Corrosion (Durability) Test 6.27 Vibration (Sinusoidal) (Operating) Test 6.28 Drop Test 6.29 Resistance to Gas Interference Test 6.30 Resistance to Cooking Oil Fume Interference Test 6.31 Resistance to Poisoning Test 6.32 Resistance to High Concentration Gas Impact Test 6.33 Resistance to Ageing Test 6.34 Longterm Stability Test 6.35 Low Concentration Carbon Monoxide Response Performance Test 6.36 MultiTarget Gas Response Performance Test 7 Inspection Rules 7.1 Factory Inspection 7.2 Type Inspection 7.3 Inservice Inspection 8 Marking and Packaging 8.1 Product Marking 8.2 Quality Inspection Marking 8.3 Packaging Annex A (Informative) Guide for application places of point type combustible gas detectors for industrial and commercial use A.1 Industrial Detectors A.2 Commercial Detectors A.3 Pipeline and Well Detectors Annex B (Normative) Model designation rules for combustible gas detector products B.1 Designation Principles B.2 Designation Method Annex C (Normative) Enclosure flammability performance test C.1 General C.2 Test C.3 Requirements Annex D (Normative) Reading device for historical event records of combustible gas detectors D.1 General Requirements D.2 Physical Characteristics D.3 Communication Protocol Annex E (Normative) Test equipment for resistance to cooking oil fume interference E.1 Test Equipment E.2 Technical Parameters Annex F (Normative) Test equipment and test methods for combustible gas detectors F.1 Test Equipment F.2 Test Method for Measuring Alarm Actuation Value F.3 Test Method for Testing Interference Resistance of Specimens Using Liquid Reagents F.4 Test Method for Testing MultiTarget Gas Response Performance Using Liquid Reagents Combustible gas detectors – Part 1: Point type combustible gas detectors for industrial and commercial use 1 Scope This document defines the terms and definitions for point type combustible gas detectors for industrial and commercial use, specifies classification and naming, requirements, inspection rules, and marking and packaging, and describes the corresponding test methods. This document applies to the design, manufacture and inspection of point type combustible gas detector (hereinafter referred to as "detector") products used in industrial and commercial premises. 2 Normative References The contents of the following documents constitute essential provisions of this document through normative reference. For dated references, only the edition cited applies. For undated references, the latest edition (including all amendments) applies. GB/T 3836.1 Explosive atmospheres — Part 1: Equipment — General requirements GB/T 4208-2017 Degrees of protection provided by enclosure (IP code) GB/T 9969 General principles for preparation of instructions for use of industrial products GB 12978 Inspection rules for fire electronic products GB/T 16838 Environmental test methods and severities for fire electronic products GB/T 17626.2 Electromagnetic compatibility — Testing and measurement techniques — Electrostatic discharge immunity test GB/T 17626.3 Electromagnetic compatibility — Testing and measurement techniques — Part 3: Radiated, radiofrequency, electromagnetic field immunity test GB/T 17626.4 Electromagnetic compatibility — Testing and measurement techniques — Electrical fast transient/burst immunity test GB/T 17626.5 Electromagnetic compatibility — Testing and measurement techniques — Surge (impact) immunity test GB/T 17626.6 Electromagnetic compatibility — Testing and measurement techniques — Immunity to conducted disturbances induced by radiofrequency fields 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 lower explosive limit; LEL Under standard atmospheric conditions, the minimum concentration of a combustible gas or vapour in air that will explode. 3.2 monitoring condition The state of a detector after it has been powered on and is operating normally, without any combustible gas alarm, fault, selftest, sensor endoflife, etc., occurring. 3.3 industrial detectors Detectors installed in industrial sites where various types of combustible gases and volatile combustible liquids are stored, transported, used or produced, for the purpose of realtime monitoring of the concentration of combustible gases and vapours in the area. 3.4 commercial detectors Detectors installed in various public and commercial premises other than residential environments such as houses and apartments, for the purpose of realtime monitoring of the concentration of methane, propane and carbon monoxide in the area. 3.5 industrial and commercial detectors Detectors that have both the functions of industrial detectors and commercial detectors, meeting the performance requirements for both industrial and commercial premises. 3.6 pipeline and well detectors Detectors installed in closed environments such as underground pipelines and shafts where there is a risk of combustible gas accumulation, for the purpose of periodic monitoring of the concentration of combustible gases in the area. 3.7 systembased detectors Industrial or commercial detectors that have their own operating status indication function and, after establishing communication with control and indicating equipment such as a combustible gas alarm control unit via wired or wireless communication means, can realise the functions of a combustible gas detection and alarm system. 3.8 standalone detectors Industrial or commercial detectors that can be used independently at the installation site, having functions such as operating status indication, measured concentration display, audible signal output, historical event record storage, and control activation of field actuators. 4 Classification and naming 4.1 Detectors are classified according to the applicable location as: a)Industrial detectors; b) Commercial detectors; c) Industrial and commercial detectors; d) Pipeline and well detectors. NOTE: Typical application places for each type of detector product are given in Annex A. 4.2 Detectors are classified according to the sampling method as: a)Free diffusion detectors; b) Active suction detectors. 4.3 Industrial detectors, commercial detectors, and industrial and commercial detectors are classified according to the mode of operation as: a)Systembased detectors; b) Standalone detectors. 4.4 Industrial detectors are classified according to the measurement range as: a)Detectors with a measurement range from 3% LEL to 100% LEL; b) Detectors with a measurement range below 3% LEL (including detectors for carbon monoxide). 4.5 Industrial detectors are classified according to the use environment as: a)Detectors for indoor use; b) Detectors for outdoor use. 5 Requirements 5.1 General requirements 5.1.1 Detectors shall meet the requirements of this clause and shall be tested in accordance with Clause 6 to confirm conformity with the requirements of this clause. 5.1.2 The model designation of detectors shall comply with Annex B. 5.2 Enclosure and explosion protection requirements 5.2.1 The surface of detectors shall be free from corrosion, coating peeling and blistering, and free from obvious scratches, cracks, burrs and other mechanical damage. Fastened parts shall be free from loosening.
Contents of GB 15322.1-2026
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 3680948734
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 15322.1-2026, GB/T 15322.1-2026, GBT 15322.1-2026, GB15322.1-2026, GB 15322.1, GB15322.1, GB/T15322.1-2026, GB/T 15322.1, GB/T15322.1, GBT15322.1-2026, GBT 15322.1, GBT15322.1