2026-9-27 216.73.216.203
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB 29415-2026
GB 29415-2026   Fire-resistant cable trunking (English)
Standard No.: GB 29415-2026 Status:to be valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 9000 words Translation Price(USD):270.0 remind me the price change

Email:

Implemented on:2027-9-1 Delivery: via email in 1~3 business day

→ → →

,,2027-9-1,BD6F2F20F870F8EA1788405991404
Standard No.: GB 29415-2026
English Name: Fire-resistant cable trunking
Chinese Name: 耐火电缆槽盒
Professional Classification: GB    National Standard
Source Content Issued by: SAMR, SAC
Issued on: 2026-08-27
Implemented on: 2027-9-1
Status: to be valid
Superseding:GB 29415-2013 Fire-resistant cable trunk
Target Language: English
File Format: PDF
Word Count: 9000 words
Translation Price(USD): 270.0
Delivery: via email in 1~3 business day
GB 29415-2026 Fire-resistant cable trunking English, Anglais, Englisch, Inglés, えいご This is a draft translation for reference among interesting stakeholders. The finalized translation (passing through draft translation, self-check, revision and verification) will be delivered upon being ordered. ICS CCS National Standard of the People's Republic of China ‌GB 29415-2026 Fire-resistant cable trunking 耐火电缆槽盒 Issue date: 2026-06-27 Implementation date: 2027-05-01 Issued by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China the Standardization Administration of the People's Republic of China Contents Foreword 1 Scope 2 Normative references 3 Terms and definitions 4 Classification and codes, specifications, models 4.1 Classification and codes 4.2 Specifications 4.3 Models 5 Technical requirements 5.1 Appearance 5.2 Material performance 5.3 Load-bearing capacity 5.4 Fire resistance 6 Test methods 6.1 Appearance 6.2 Material performance 6.3 Load-bearing capacity 6.4 Fire resistance 7 Inspection rules 7.1 Factory inspection 7.2 Type inspection 8 Marking, packaging, transportation and storage 8.1 Marking 8.2 Packaging 8.3 Transportation 8.4 Storage Bibliography Fire-resistant cable trunking 1 Scope This document specifies the classification and codes, specifications, models, technical requirements, inspection rules, marking, packaging, transportation and storage for fire-resistant cable trunking (hereinafter referred to as "trunking"), and describes the corresponding test methods. This document is applicable to the design, manufacture and quality inspection of fire-resistant cable trunking used in industrial and civil buildings for laying power cables, control cables and communication cables of 1 kV and below. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition (including any amendments) applies. GB 8624, Classification for burning behaviour of building materials and products GB/T 9969, General principles for instruction for use of industrial products GB/T 9978.1, Fire-resistance tests — Elements of building construction — Part 1: General requirements 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 fire-resistant cable trunking A continuous rigid structure composed of a tray and a cover plate, used for laying and supporting cables, capable of meeting specified fire-resistant working duration requirements. 3.2 working duration under fire test The time from the start of the fire resistance test under standard temperature rise conditions until the 2 A fuse connected to the cable inside the trunking specimen blows. 3.3 safe working load The maximum load that can be safely applied during normal use. 4 Classification and codes, specifications, models 4.1 Classification and codes 4.1.1 Trunking is classified into three categories according to the type of cable laid inside, with classification and codes given in Table 1. 4.1.2 The fire resistance of trunking is classified into four categories according to the working duration under fire test, with classification and codes given in Table 2. 4.2 Specifications The specifications of trunking are usually expressed by the internal cavity width and height, with common specifications given in Table 3. 4.3 Models The model designation method for trunking is shown in Figure 1. Example 1: NDH-400×150-DL/F1.0, KZ/F0.5-ventilated type, indicating an internal cavity width of 400 mm, height of 150 mm, fire resistance of Class F1.0 when laying power cables (working duration under fire test ≥ 60 min), fire resistance of Class F0.5 when laying control cables (working duration under fire test ≥ 30 min), working duration under fire test of less than 30 min when laying communication cables, and enterprise-defined content of ventilated type. Example 2: NDH-600×150-DL/F1.5, KZ/F1.5, TX/F1.5-abc, indicating an internal cavity width of 600 mm, height of 150 mm, fire resistance of Class F1.5 when laying power cables (working duration under fire test ≥ 90 min), fire resistance of Class F1.5 when laying control cables (working duration under fire test ≥ 90 min), fire resistance of Class F1.5 when laying communication cables (working duration under fire test ≥ 90 min), and enterprise-defined content of abc. 5 Technical requirements 5.1 Appearance 5.1.1 The surfaces of all components of the trunking shall be flat, free from cracks, indentations and obvious depressions, hammer marks and burrs. 5.1.2 The welded surfaces of the trunking shall be smooth, free from blowholes, slag inclusions and porosity. 5.1.3 The protective layer of coated components of the trunking shall be uniform, free from peeling, flaking, blistering, missed coating or runs. 5.1.4 A permanent product marking nameplate shall be applied to a prominent position on the trunking, and shall not be attached by adhesive. The nameplate shall have clear and legible lettering, and its content shall comply with the requirements of 8.1. 5.2 Material performance 5.2.1 Where metal sheets are used for manufacturing the trunking, the minimum permissible thickness of the sheets shall comply with the provisions of Table 4. 5.2.2 The burning behaviour of non-metallic sheets and filling materials used for manufacturing the trunking shall comply with Class A as specified in GB 8624. 5.3 Load-bearing capacity The commissioning party of the test shall specify the safe working load of the trunking in the technical documents. The ratio of the maximum deflection of the trunking under the safe working load to its calculated span shall not exceed 1/200. 5.4 Fire resistance The fire resistance of the trunking shall comply with the provisions of Table 2.
Code of China
Standard
GB 29415-2026  Fire-resistant cable trunking (English)
Standard No.GB 29415-2026
Statusto be valid
LanguageEnglish
File FormatPDF
Word Count9000 words
Translation Price(USD)270.0
Implemented on2027-9-1
Deliveryvia email in 1~3 business day
Detail of GB 29415-2026
Standard No.
GB 29415-2026
English Name
Fire-resistant cable trunking
Chinese Name
耐火电缆槽盒
Chinese Classification
Professional Classification
GB
ICS Classification
Issued by
SAMR, SAC
Issued on
2026-08-27
Implemented on
2027-9-1
Status
to be valid
Superseded by
Superseded on
Abolished on
Superseding
GB 29415-2013 Fire-resistant cable trunk
Language
English
File Format
PDF
Word Count
9000 words
Translation Price(USD)
270.0
Keywords
GB 29415-2026, GB/T 29415-2026, GBT 29415-2026, GB29415-2026, GB 29415, GB29415, GB/T29415-2026, GB/T 29415, GB/T29415, GBT29415-2026, GBT 29415, GBT29415
Introduction of GB 29415-2026
GB 29415-2026 Fire-resistant cable trunking English, Anglais, Englisch, Inglés, えいご This is a draft translation for reference among interesting stakeholders. The finalized translation (passing through draft translation, self-check, revision and verification) will be delivered upon being ordered. ICS CCS National Standard of the People's Republic of China ‌GB 29415-2026 Fire-resistant cable trunking 耐火电缆槽盒 Issue date: 2026-06-27 Implementation date: 2027-05-01 Issued by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China the Standardization Administration of the People's Republic of China Contents Foreword 1 Scope 2 Normative references 3 Terms and definitions 4 Classification and codes, specifications, models 4.1 Classification and codes 4.2 Specifications 4.3 Models 5 Technical requirements 5.1 Appearance 5.2 Material performance 5.3 Load-bearing capacity 5.4 Fire resistance 6 Test methods 6.1 Appearance 6.2 Material performance 6.3 Load-bearing capacity 6.4 Fire resistance 7 Inspection rules 7.1 Factory inspection 7.2 Type inspection 8 Marking, packaging, transportation and storage 8.1 Marking 8.2 Packaging 8.3 Transportation 8.4 Storage Bibliography Fire-resistant cable trunking 1 Scope This document specifies the classification and codes, specifications, models, technical requirements, inspection rules, marking, packaging, transportation and storage for fire-resistant cable trunking (hereinafter referred to as "trunking"), and describes the corresponding test methods. This document is applicable to the design, manufacture and quality inspection of fire-resistant cable trunking used in industrial and civil buildings for laying power cables, control cables and communication cables of 1 kV and below. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition (including any amendments) applies. GB 8624, Classification for burning behaviour of building materials and products GB/T 9969, General principles for instruction for use of industrial products GB/T 9978.1, Fire-resistance tests — Elements of building construction — Part 1: General requirements 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 fire-resistant cable trunking A continuous rigid structure composed of a tray and a cover plate, used for laying and supporting cables, capable of meeting specified fire-resistant working duration requirements. 3.2 working duration under fire test The time from the start of the fire resistance test under standard temperature rise conditions until the 2 A fuse connected to the cable inside the trunking specimen blows. 3.3 safe working load The maximum load that can be safely applied during normal use. 4 Classification and codes, specifications, models 4.1 Classification and codes 4.1.1 Trunking is classified into three categories according to the type of cable laid inside, with classification and codes given in Table 1. 4.1.2 The fire resistance of trunking is classified into four categories according to the working duration under fire test, with classification and codes given in Table 2. 4.2 Specifications The specifications of trunking are usually expressed by the internal cavity width and height, with common specifications given in Table 3. 4.3 Models The model designation method for trunking is shown in Figure 1. Example 1: NDH-400×150-DL/F1.0, KZ/F0.5-ventilated type, indicating an internal cavity width of 400 mm, height of 150 mm, fire resistance of Class F1.0 when laying power cables (working duration under fire test ≥ 60 min), fire resistance of Class F0.5 when laying control cables (working duration under fire test ≥ 30 min), working duration under fire test of less than 30 min when laying communication cables, and enterprise-defined content of ventilated type. Example 2: NDH-600×150-DL/F1.5, KZ/F1.5, TX/F1.5-abc, indicating an internal cavity width of 600 mm, height of 150 mm, fire resistance of Class F1.5 when laying power cables (working duration under fire test ≥ 90 min), fire resistance of Class F1.5 when laying control cables (working duration under fire test ≥ 90 min), fire resistance of Class F1.5 when laying communication cables (working duration under fire test ≥ 90 min), and enterprise-defined content of abc. 5 Technical requirements 5.1 Appearance 5.1.1 The surfaces of all components of the trunking shall be flat, free from cracks, indentations and obvious depressions, hammer marks and burrs. 5.1.2 The welded surfaces of the trunking shall be smooth, free from blowholes, slag inclusions and porosity. 5.1.3 The protective layer of coated components of the trunking shall be uniform, free from peeling, flaking, blistering, missed coating or runs. 5.1.4 A permanent product marking nameplate shall be applied to a prominent position on the trunking, and shall not be attached by adhesive. The nameplate shall have clear and legible lettering, and its content shall comply with the requirements of 8.1. 5.2 Material performance 5.2.1 Where metal sheets are used for manufacturing the trunking, the minimum permissible thickness of the sheets shall comply with the provisions of Table 4. 5.2.2 The burning behaviour of non-metallic sheets and filling materials used for manufacturing the trunking shall comply with Class A as specified in GB 8624. 5.3 Load-bearing capacity The commissioning party of the test shall specify the safe working load of the trunking in the technical documents. The ratio of the maximum deflection of the trunking under the safe working load to its calculated span shall not exceed 1/200. 5.4 Fire resistance The fire resistance of the trunking shall comply with the provisions of Table 2.
Contents of GB 29415-2026
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 3680948734
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 29415-2026, GB/T 29415-2026, GBT 29415-2026, GB29415-2026, GB 29415, GB29415, GB/T29415-2026, GB/T 29415, GB/T29415, GBT29415-2026, GBT 29415, GBT29415