GB 3095-2026   Ambient air quality standards (English Version)
Standard No.: GB 3095-2026 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 5500 words Translation Price(USD):165.0 remind me the price change

Email:

Implemented on:2026-3-1 Delivery: via email in 1~3 business day

→ → →

,,2026-3-1,1F2AFE0D91E212A41772095961544
Standard No.: GB 3095-2026
English Name: Ambient air quality standards
Chinese Name: 环境空气质量标准
Chinese Classification: Z50    Environmental Quality Standard for atmosphere, water and soil
Professional Classification: GB    National Standard
ICS Classification: 13.040.20 13.040.20    Ambient atmospheres 13.040.20
Source Content Issued by: MEE; SAMR
Issued on: 2026-02-27
Implemented on: 2026-3-1
Status: valid
Superseding:GB 3095-2012 Ambient air quality standard
GB 3095-2012/XG1-2018 Ambient air quality standard||includes Amendment 1
Target Language: English
File Format: PDF
Word Count: 5500 words
Translation Price(USD): 165.0
Delivery: via email in 1~3 business day
GB 3095-2026 Ambient air quality standards English, Anglais, Englisch, Inglés, えいご This is a draft translation for reference among interesting stakeholders. The finalized translation (passing through draft translation, self-check, revision and verification) will be delivered upon being ordered. ICS 13.220.10 CCS H 57 National Standard of the People's Republic of China ‌GB/T 3095-2026 Replaces GB/T 3095-2012 Ambient air quality standards 环境空气质量标准 Issue date: 2026-02-13 Implementation date: 2026-03-01 Issued by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China the Standardization Administration of the People's Republic of China Contents Foreword 1 Applicable Scope 2 Normative References 3 Terms and Definitions 4 Classification of Ambient Air Functional Zones and Quality Requirements 5 Monitoring 6 Validity Provisions for Data Statistics 7 Implementation and Supervision Annex A (Informative Annex) Reference Concentration Limits for Cadmium, Mercury, Arsenic, Hexavalent Chromium, and Fluorides in Ambient Air Ambient Air Quality Standards 1 Applicable Scope This standard specifies the classification of ambient air functional zones, standard grading, pollutant items, averaging times and concentration limits, monitoring methods, validity provisions for data statistics, and implementation and supervision. This standard is applicable to the evaluation and management of ambient air quality. 2 Normative References The following documents or clauses therein are referenced in this standard. For dated references, only the edition cited applies to this standard. For undated references, the latest edition (including any amendments) applies to this standard. If other documents are repealed, modified, or revised by new documents, the new documents apply to this standard. GB/T 9801, Ambient air - Determination of carbon monoxide - Non-dispersive infrared method HJ 193, Technical specification for installation and acceptance of continuous automatic monitoring system for gaseous pollutants (SO₂, NO₂, O₃, CO) in ambient air HJ 194, Technical specification for manual monitoring of ambient air quality HJ 479, Ambient air - Determination of nitrogen oxides (nitric oxide and nitrogen dioxide) - N-(1-naphthyl)ethylenediamine dihydrochloride spectrophotometric method HJ 482, Ambient air - Determination of sulfur dioxide - Formaldehyde absorbing-pararosaniline spectrophotometric method HJ 504, Ambient air - Determination of ozone - Indigo disulfonate spectrophotometric method HJ 539, Ambient air - Determination of lead - Graphite furnace atomic absorption spectrophotometric method HJ 590, Ambient air - Determination of ozone - Ultraviolet photometric method HJ 618, Ambient air - Determination of PM₁₀ and PM₂.₅ - Gravimetric method HJ 630, Technical guideline for quality management of environmental monitoring HJ 646, Ambient air and stationary source emission - Determination of polycyclic aromatic hydrocarbons in gas and particulate phase - Gas chromatography/mass spectrometry HJ 647, Ambient air and stationary source emission - Determination of polycyclic aromatic hydrocarbons in gas and particulate phase - High performance liquid chromatography HJ 653, Technical requirements and test procedures for continuous automatic monitoring system of ambient air particulate matter (PM₁₀ and PM₂.₅) HJ 654, Technical requirements and test procedures for continuous automatic monitoring system for gaseous pollutants (SO₂, NO₂, O₃, CO) in ambient air HJ 655, Technical specification for installation and acceptance of continuous automatic monitoring system of ambient air particulate matter (PM₁₀ and PM₂.₅) HJ 657, Ambient air and stationary source emission - Determination of metal elements in particulate matter - Inductively coupled plasma mass spectrometry HJ 664, Technical specification for siting of ambient air quality monitoring points (on trial) HJ 777, Ambient air and stationary source emission - Determination of metal elements in particulate matter - Inductively coupled plasma optical emission spectrometry HJ 817, Technical specification for operation and quality control of continuous automatic monitoring system of ambient air particulate matter (PM₁₀ and PM₂.₅) HJ 818, Technical specification for operation and quality control of continuous automatic monitoring system for gaseous pollutants (SO₂, NO₂, O₃, CO) in ambient air HJ 829, Ambient air - Determination of inorganic elements in particulate matter - Energy dispersive X-ray fluorescence spectrometry HJ 830, Ambient air - Determination of inorganic elements in particulate matter - Wavelength dispersive X-ray fluorescence spectrometry HJ 956, Ambient air - Determination of benzo[a]pyrene - High performance liquid chromatography HJ 965, Ambient air - Automatic determination of carbon monoxide - Non-dispersive infrared method HJ 1043, Ambient air - Automatic determination of nitrogen oxides - Chemiluminescence method HJ 1044, Ambient air - Automatic determination of sulfur dioxide - Ultraviolet fluorescence method HJ 1225, Ambient air - Automatic determination of ozone - Chemiluminescence method HJ 1263, Ambient air - Determination of total suspended particulate - Gravimetric method 3 Terms and Definitions The following terms and definitions apply to this standard. 3.1 ambient air The outdoor air to which people, plants, animals, and structures are exposed. 3.2 total suspended particle (TSP) Particles in ambient air with an aerodynamic diameter less than or equal to 100 μm. 3.3 lead Lead and its compounds present in total suspended particles. 3.4 particulate matter (PM₁₀) Particles in ambient air with an aerodynamic diameter less than or equal to 10 μm, also known as inhalable particulate matter. 3.5 particulate matter (PM₂.₅) Particles in ambient air with an aerodynamic diameter less than or equal to 2.5 μm, also known as fine particulate matter. 3.6 lead Lead and its compounds present in total suspended particles. 3.7 benzo[a]pyrene (BaP) Benzo[a]pyrene present in particulate matter (particle size ≤ 10 μm). 3.8 1-hour average The arithmetic average of pollutant concentrations over any 1-hour period. 3.9 8-hour average The arithmetic average of average concentrations over 8 consecutive hours, also known as the 8-hour moving average. 3.10 maximum daily 8-hour average The maximum value of the 8-hour moving average within a calendar day. 3.11 daily average The arithmetic average of 24-hour average concentrations over a calendar day, also known as the 24-hour average. 3.12 monthly average The arithmetic average of daily average concentrations within a calendar month. 3.13 quarterly average The arithmetic average of daily average concentrations within a calendar quarter. 3.14 annual mean The arithmetic average of daily average concentrations within a calendar year. 3.15 reference state The state when the atmospheric temperature is 298.15 K and the atmospheric pressure is 1013.25 hPa. 3.16 reference method National ecological environment standard method serving as the basis for evaluating the equivalence of ambient air pollutant monitoring methods. 3.17 equivalent method An ecological environment monitoring method confirmed, through equivalence evaluation organized by the competent department of ecological environment under the State Council, to be equivalent to the reference method specified in this standard. 4 Classification of Ambient Air Functional Zones and Quality Requirements 4.1 Classification of Ambient Air Functional Zones Ambient air functional zones are divided into two categories: Category I zones are national parks, nature reserves, natural parks, and other areas requiring special protection; Category II zones are residential areas, mixed commercial-traffic-residential areas, cultural areas, industrial areas, and rural areas. 4.2 Quality Requirements for Ambient Air Functional Zones Category I zones apply Class I concentration limits, and Category II zones apply Class II concentration limits. The quality requirements for Category I and Category II ambient air functional zones are specified in Table 1 and Table 2.
Code of China
Standard
GB 3095-2026  Ambient air quality standards (English Version)
Standard No.GB 3095-2026
Statusvalid
LanguageEnglish
File FormatPDF
Word Count5500 words
Price(USD)165.0
Implemented on2026-3-1
Deliveryvia email in 1~3 business day
Detail of GB 3095-2026
Standard No.
GB 3095-2026
English Name
Ambient air quality standards
Chinese Name
环境空气质量标准
Chinese Classification
Z50
Professional Classification
GB
ICS Classification
Issued by
MEE; SAMR
Issued on
2026-02-27
Implemented on
2026-3-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
GB 3095-2012 Ambient air quality standard
GB 3095-2012/XG1-2018 Ambient air quality standard||includes Amendment 1
Language
English
File Format
PDF
Word Count
5500 words
Price(USD)
165.0
Keywords
GB 3095-2026, GB/T 3095-2026, GBT 3095-2026, GB3095-2026, GB 3095, GB3095, GB/T3095-2026, GB/T 3095, GB/T3095, GBT3095-2026, GBT 3095, GBT3095
Introduction of GB 3095-2026
GB 3095-2026 Ambient air quality standards English, Anglais, Englisch, Inglés, えいご This is a draft translation for reference among interesting stakeholders. The finalized translation (passing through draft translation, self-check, revision and verification) will be delivered upon being ordered. ICS 13.220.10 CCS H 57 National Standard of the People's Republic of China ‌GB/T 3095-2026 Replaces GB/T 3095-2012 Ambient air quality standards 环境空气质量标准 Issue date: 2026-02-13 Implementation date: 2026-03-01 Issued by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China the Standardization Administration of the People's Republic of China Contents Foreword 1 Applicable Scope 2 Normative References 3 Terms and Definitions 4 Classification of Ambient Air Functional Zones and Quality Requirements 5 Monitoring 6 Validity Provisions for Data Statistics 7 Implementation and Supervision Annex A (Informative Annex) Reference Concentration Limits for Cadmium, Mercury, Arsenic, Hexavalent Chromium, and Fluorides in Ambient Air Ambient Air Quality Standards 1 Applicable Scope This standard specifies the classification of ambient air functional zones, standard grading, pollutant items, averaging times and concentration limits, monitoring methods, validity provisions for data statistics, and implementation and supervision. This standard is applicable to the evaluation and management of ambient air quality. 2 Normative References The following documents or clauses therein are referenced in this standard. For dated references, only the edition cited applies to this standard. For undated references, the latest edition (including any amendments) applies to this standard. If other documents are repealed, modified, or revised by new documents, the new documents apply to this standard. GB/T 9801, Ambient air - Determination of carbon monoxide - Non-dispersive infrared method HJ 193, Technical specification for installation and acceptance of continuous automatic monitoring system for gaseous pollutants (SO₂, NO₂, O₃, CO) in ambient air HJ 194, Technical specification for manual monitoring of ambient air quality HJ 479, Ambient air - Determination of nitrogen oxides (nitric oxide and nitrogen dioxide) - N-(1-naphthyl)ethylenediamine dihydrochloride spectrophotometric method HJ 482, Ambient air - Determination of sulfur dioxide - Formaldehyde absorbing-pararosaniline spectrophotometric method HJ 504, Ambient air - Determination of ozone - Indigo disulfonate spectrophotometric method HJ 539, Ambient air - Determination of lead - Graphite furnace atomic absorption spectrophotometric method HJ 590, Ambient air - Determination of ozone - Ultraviolet photometric method HJ 618, Ambient air - Determination of PM₁₀ and PM₂.₅ - Gravimetric method HJ 630, Technical guideline for quality management of environmental monitoring HJ 646, Ambient air and stationary source emission - Determination of polycyclic aromatic hydrocarbons in gas and particulate phase - Gas chromatography/mass spectrometry HJ 647, Ambient air and stationary source emission - Determination of polycyclic aromatic hydrocarbons in gas and particulate phase - High performance liquid chromatography HJ 653, Technical requirements and test procedures for continuous automatic monitoring system of ambient air particulate matter (PM₁₀ and PM₂.₅) HJ 654, Technical requirements and test procedures for continuous automatic monitoring system for gaseous pollutants (SO₂, NO₂, O₃, CO) in ambient air HJ 655, Technical specification for installation and acceptance of continuous automatic monitoring system of ambient air particulate matter (PM₁₀ and PM₂.₅) HJ 657, Ambient air and stationary source emission - Determination of metal elements in particulate matter - Inductively coupled plasma mass spectrometry HJ 664, Technical specification for siting of ambient air quality monitoring points (on trial) HJ 777, Ambient air and stationary source emission - Determination of metal elements in particulate matter - Inductively coupled plasma optical emission spectrometry HJ 817, Technical specification for operation and quality control of continuous automatic monitoring system of ambient air particulate matter (PM₁₀ and PM₂.₅) HJ 818, Technical specification for operation and quality control of continuous automatic monitoring system for gaseous pollutants (SO₂, NO₂, O₃, CO) in ambient air HJ 829, Ambient air - Determination of inorganic elements in particulate matter - Energy dispersive X-ray fluorescence spectrometry HJ 830, Ambient air - Determination of inorganic elements in particulate matter - Wavelength dispersive X-ray fluorescence spectrometry HJ 956, Ambient air - Determination of benzo[a]pyrene - High performance liquid chromatography HJ 965, Ambient air - Automatic determination of carbon monoxide - Non-dispersive infrared method HJ 1043, Ambient air - Automatic determination of nitrogen oxides - Chemiluminescence method HJ 1044, Ambient air - Automatic determination of sulfur dioxide - Ultraviolet fluorescence method HJ 1225, Ambient air - Automatic determination of ozone - Chemiluminescence method HJ 1263, Ambient air - Determination of total suspended particulate - Gravimetric method 3 Terms and Definitions The following terms and definitions apply to this standard. 3.1 ambient air The outdoor air to which people, plants, animals, and structures are exposed. 3.2 total suspended particle (TSP) Particles in ambient air with an aerodynamic diameter less than or equal to 100 μm. 3.3 lead Lead and its compounds present in total suspended particles. 3.4 particulate matter (PM₁₀) Particles in ambient air with an aerodynamic diameter less than or equal to 10 μm, also known as inhalable particulate matter. 3.5 particulate matter (PM₂.₅) Particles in ambient air with an aerodynamic diameter less than or equal to 2.5 μm, also known as fine particulate matter. 3.6 lead Lead and its compounds present in total suspended particles. 3.7 benzo[a]pyrene (BaP) Benzo[a]pyrene present in particulate matter (particle size ≤ 10 μm). 3.8 1-hour average The arithmetic average of pollutant concentrations over any 1-hour period. 3.9 8-hour average The arithmetic average of average concentrations over 8 consecutive hours, also known as the 8-hour moving average. 3.10 maximum daily 8-hour average The maximum value of the 8-hour moving average within a calendar day. 3.11 daily average The arithmetic average of 24-hour average concentrations over a calendar day, also known as the 24-hour average. 3.12 monthly average The arithmetic average of daily average concentrations within a calendar month. 3.13 quarterly average The arithmetic average of daily average concentrations within a calendar quarter. 3.14 annual mean The arithmetic average of daily average concentrations within a calendar year. 3.15 reference state The state when the atmospheric temperature is 298.15 K and the atmospheric pressure is 1013.25 hPa. 3.16 reference method National ecological environment standard method serving as the basis for evaluating the equivalence of ambient air pollutant monitoring methods. 3.17 equivalent method An ecological environment monitoring method confirmed, through equivalence evaluation organized by the competent department of ecological environment under the State Council, to be equivalent to the reference method specified in this standard. 4 Classification of Ambient Air Functional Zones and Quality Requirements 4.1 Classification of Ambient Air Functional Zones Ambient air functional zones are divided into two categories: Category I zones are national parks, nature reserves, natural parks, and other areas requiring special protection; Category II zones are residential areas, mixed commercial-traffic-residential areas, cultural areas, industrial areas, and rural areas. 4.2 Quality Requirements for Ambient Air Functional Zones Category I zones apply Class I concentration limits, and Category II zones apply Class II concentration limits. The quality requirements for Category I and Category II ambient air functional zones are specified in Table 1 and Table 2.
Contents of GB 3095-2026
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Contact us via WeChat
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 3680948734
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 3095-2026, GB/T 3095-2026, GBT 3095-2026, GB3095-2026, GB 3095, GB3095, GB/T3095-2026, GB/T 3095, GB/T3095, GBT3095-2026, GBT 3095, GBT3095