2023-3-27 34.232.62.64
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB 3836.20-2010
GB 3836.20-2010   Explosive atmospheres - Part 20: Equipment with equipment protection level (EPL) Ga (English Version)
Standard No.: GB 3836.20-2010 Status:valid remind me the status change

Email:

Language:English File Format:PDF
Word Count: 7000 words Price(USD):170.0 remind me the price change

Email:

Implemented on:2011-9-1 Delivery: via email in 1 business day
,,
Standard No.: GB 3836.20-2010
English Name: Explosive atmospheres - Part 20: Equipment with equipment protection level (EPL) Ga
Chinese Name: 爆炸性环境 第20部分:设备保护级别(EPL)为Ga级的设备
Chinese Classification: K35    Explosion-proof electric apparatus
Professional Classification: GB    National Standard
ICS Classification: 29.260.20 29.260.20    Electrical apparatus for explosive atmospheres 29.260.20
Issued by: AQSIQ, SAC
Issued on: 2010-11-10
Implemented on: 2011-9-1
Status: valid
Language: English
File Format: PDF
Word Count: 7000 words
Price(USD): 170.0
Delivery: via email in 1 business day
1 Scope This Part of GB 3836 specifies the particular requirements for construction, test and marking for electrical equipment that provides equipment protection level (EPL) Ga. This electrical equipment, within the operational parameters specified by the manufacturer, ensures a very high level of protection that includes rare faults related to the equipment or two faults occurring independently of each other. Note 1: A malfunction may result from a failure of the component parts of the electrical equipment or from anticipated externally applied influences. Two independent malfunctions which may occur more frequently and which, separately, would not create an ignition hazard but which, in combination, could create a potential ignition hazard, should be regarded as occurring together to form a rare fault. Note 2: This electrical equipment is intended for use in zone 0 hazardous areas, in which explosive gas atmospheres caused by mixtures of air and gases, vapours or mists under normal atmospheric conditions are present continuously, for long periods or frequently. This standard also applies to equipment mounted across a boundary where different protection levels may be required. Example: In the wall of a storage vessel containing zone 0 with an ambient defined as zone 1. This Part also applies to equipment installed in an area requiring a lower protection level, but electrically connected to equipment with equipment protection level (EPL) Ga (associated apparatus). This Part supplements the general requirements in GB 3836.1-2010 and the requirements of the standardized types of protection, in accordance with the GB 3836 series, to adapt the level of safety provided by those standards in order to provide EPL Ga. Note 3: In designing equipment for operation in explosive gas atmospheres under conditions other than the atmospheric conditions given in GB 3836.1-2010, this standard may be used as a guide. However, additional testing is recommended related specifically to the intended conditions of use. This is particularly important when the types of protection ‘Flameproof enclosures’ (GB 3836.2-2010) and ‘Intrinsic safety’ (GB 3836.4-2010) are applied. Note 4: The classification of hazardous areas in zones is defined in GB 3836.14-2000. Note 5: There may be other non-electrical sources of ignition (for example ultrasonic, optical or ionizing radiation) that are not addressed by this standard; these should also be taken into consideration (see, GB/T 25285.1-2010). Note 6: This concept provides equipment protection level (EPL) Ga. For further information, see Appendix A. 2 Normative References The following normative documents contain provisions which, through reference in this text, constitute provisions of this Part of GB 3836. For dated references, subsequent amendments to, or revisions of, any of these publications do not apply. However, parties to agreements based on this Part are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below. For undated references, the latest edition of the normative document referred to applies.
Foreword II 1 Scope 2 Normative References 3 Terms and Definitions 4 Requirements for Design and Construction 5 Type Tests 6 Marking 7 Information for Use Appendix A (Informative) Introduction of an Alternative Risk Assessment Method Encompassing “Equipment Protection Levels” for Ex Equipment
Referred in GB 3836.20-2010:
* GB 3836.1-2010 Explosive atmospheres—Part 1:Equipment—General requirements
* GB 3836.2-2010 Explosive atmospheres—Part 2:Equipment protection by flameproof enclosures“d”
* GB 3836.4-2010 Explosive atmospheres—Part 4:Equipment protection by intrinsic safety i
* GB 3836.9-2006 Electrical apparatus for explosive gas atmospheres - Part 9: Encapsulation “m”
* GB 3836.14-2000 Electrical apparatus for explosive gas atmospheres--Part 14: Classification of hazardous areas
* GB 3836.15-2000 Electrical apparatus for explosive gas atmospheres--Part 15:Electrical installations in hazardous areas(other than mines)
* GB 4208-2008 Degrees of Protection Provided By Enclosure (IP Code)
* GB/T 5169.16-2008 Fire hazard testing for electric and electronic products - Part 16: Test flames - 50W horizontal and vertical flame test methods
* GB 25285.1-2010 Explosive atmospheres - Explosion prevention and protection - Part 1: Basic concepts and methodology
GB 3836.20-2010 is referred in:
* GB 3836.1-2010 Explosive atmospheres—Part 1:Equipment—General requirements
* GB 3836.1-2010 Explosive atmospheres—Part 1:Equipment—General requirements
*GB/T 3836.15-2017 Explosive atmospheres—Part 15: Electrical installations design, selection and erection
Code of China
Standard
GB 3836.20-2010  Explosive atmospheres - Part 20: Equipment with equipment protection level (EPL) Ga (English Version)
Standard No.GB 3836.20-2010
Statusvalid
LanguageEnglish
File FormatPDF
Word Count7000 words
Price(USD)170.0
Implemented on2011-9-1
Deliveryvia email in 1 business day
Detail of GB 3836.20-2010
Standard No.
GB 3836.20-2010
English Name
Explosive atmospheres - Part 20: Equipment with equipment protection level (EPL) Ga
Chinese Name
爆炸性环境 第20部分:设备保护级别(EPL)为Ga级的设备
Chinese Classification
K35
Professional Classification
GB
ICS Classification
Issued by
AQSIQ, SAC
Issued on
2010-11-10
Implemented on
2011-9-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
7000 words
Price(USD)
170.0
Keywords
GB 3836.20-2010, GB/T 3836.20-2010, GBT 3836.20-2010, GB3836.20-2010, GB 3836.20, GB3836.20, GB/T3836.20-2010, GB/T 3836.20, GB/T3836.20, GBT3836.20-2010, GBT 3836.20, GBT3836.20
Introduction of GB 3836.20-2010
1 Scope This Part of GB 3836 specifies the particular requirements for construction, test and marking for electrical equipment that provides equipment protection level (EPL) Ga. This electrical equipment, within the operational parameters specified by the manufacturer, ensures a very high level of protection that includes rare faults related to the equipment or two faults occurring independently of each other. Note 1: A malfunction may result from a failure of the component parts of the electrical equipment or from anticipated externally applied influences. Two independent malfunctions which may occur more frequently and which, separately, would not create an ignition hazard but which, in combination, could create a potential ignition hazard, should be regarded as occurring together to form a rare fault. Note 2: This electrical equipment is intended for use in zone 0 hazardous areas, in which explosive gas atmospheres caused by mixtures of air and gases, vapours or mists under normal atmospheric conditions are present continuously, for long periods or frequently. This standard also applies to equipment mounted across a boundary where different protection levels may be required. Example: In the wall of a storage vessel containing zone 0 with an ambient defined as zone 1. This Part also applies to equipment installed in an area requiring a lower protection level, but electrically connected to equipment with equipment protection level (EPL) Ga (associated apparatus). This Part supplements the general requirements in GB 3836.1-2010 and the requirements of the standardized types of protection, in accordance with the GB 3836 series, to adapt the level of safety provided by those standards in order to provide EPL Ga. Note 3: In designing equipment for operation in explosive gas atmospheres under conditions other than the atmospheric conditions given in GB 3836.1-2010, this standard may be used as a guide. However, additional testing is recommended related specifically to the intended conditions of use. This is particularly important when the types of protection ‘Flameproof enclosures’ (GB 3836.2-2010) and ‘Intrinsic safety’ (GB 3836.4-2010) are applied. Note 4: The classification of hazardous areas in zones is defined in GB 3836.14-2000. Note 5: There may be other non-electrical sources of ignition (for example ultrasonic, optical or ionizing radiation) that are not addressed by this standard; these should also be taken into consideration (see, GB/T 25285.1-2010). Note 6: This concept provides equipment protection level (EPL) Ga. For further information, see Appendix A. 2 Normative References The following normative documents contain provisions which, through reference in this text, constitute provisions of this Part of GB 3836. For dated references, subsequent amendments to, or revisions of, any of these publications do not apply. However, parties to agreements based on this Part are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below. For undated references, the latest edition of the normative document referred to applies.
Contents of GB 3836.20-2010
Foreword II 1 Scope 2 Normative References 3 Terms and Definitions 4 Requirements for Design and Construction 5 Type Tests 6 Marking 7 Information for Use Appendix A (Informative) Introduction of an Alternative Risk Assessment Method Encompassing “Equipment Protection Levels” for Ex Equipment
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Foryou Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 3836.20-2010, GB/T 3836.20-2010, GBT 3836.20-2010, GB3836.20-2010, GB 3836.20, GB3836.20, GB/T3836.20-2010, GB/T 3836.20, GB/T3836.20, GBT3836.20-2010, GBT 3836.20, GBT3836.20