2026-3-3 216.73.216.182
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB 7956.22-2025
GB 7956.22-2025   Fire fighting vehicle—Part 22:Liquid extinguishing agent supply fire fighting vehicle (English Version)
Standard No.: GB 7956.22-2025 Status:to be valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 8500 words Translation Price(USD):255.0 remind me the price change

Email:

Implemented on:2027-1-1 Delivery: via email in 1~3 business day

→ → →

,,2027-1-1,919128B0276385721764728021894
Standard No.: GB 7956.22-2025
English Name: Fire fighting vehicle—Part 22:Liquid extinguishing agent supply fire fighting vehicle
Chinese Name: 消防车 第22部分:供液消防车
Professional Classification: GB    National Standard
Source Content Issued by: SAMR;SAC
Issued on: 2025-12-02
Implemented on: 2027-1-1
Status: to be valid
Target Language: English
File Format: PDF
Word Count: 8500 words
Translation Price(USD): 255.0
Delivery: via email in 1~3 business day
GB 7956.22-2025 Fire fighting vehicle—Part 22:Liquid extinguishing agent supply fire fighting vehicle English, Anglais, Englisch, Inglés, えいご This is a draft translation for reference among interesting stakeholders. The finalized translation (passing through draft translation, self-check, revision and verification) will be delivered upon being ordered. ICS CCS H National Standard of the People's Republic of China ‌GB 7956.22-2025 Fire fighting vehicles - Part 22: Liquid extinguishing agent supply fire fighting vehicle 消防车 第22部分:供液消防车 Issue date: 2025-12-02 Implementation date: 2027-01-01 Issued by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China the Standardization Administration of the People's Republic of China Contents Foreword 1 Scope 2 Normative References 3 Terms and Definitions 4 Technical Requirements 4.1 Basic Requirements 4.2 Vehicle Requirements 4.3 Chassis Modification Requirements 4.4 Marking Requirements 4.5 Firefighting Hydraulic System Requirements 4.6 Hydraulic System Requirements 4.7 Control Cabinet Requirements 4.8 Turbo-jet Extinguishing Device Requirements 4.9 Requirements for Accompanying Documentation, Tools, and Wear Parts 5 Test Methods 5.1 Basic Requirements Tests 5.2 Vehicle Requirements Tests 5.3 Tests for Chassis Modification Requirements 5.4 Marking Inspection 5.5 Firefighting Hydraulic System Tests 5.6 Hydraulic System Tests 5.7 Control Cabinet Tests 5.8 Turbo-jet Extinguishing Device Tests 5.9 Inspection of Accompanying Documentation, Tools, and Wear Parts 6 Inspection Rules 6.1 Types of Inspection 6.2 Decision Rules 7 Packaging, Transportation, and Storage 7.1 Packaging 7.2 Transportation 7.3 Storage Fire Fighting Vehicles - Part 22: Liquid Extinguishing Agent Supply Fire Fighting Vehicles 1 Scope This document specifies the technical requirements, inspection rules, packaging, transportation, and storage requirements for liquid extinguishing agent supply fire fighting vehicles, and describes the relevant test methods. This document is applicable to the design, manufacture, and inspection of liquid extinguishing agent supply fire fighting vehicles (hereinafter referred to as "liquid supply vehicles"). 2 Normative References The contents of the following documents constitute indispensable clauses of this document through normative reference. For dated references, only the edition corresponding to the date applies. For undated references, the latest edition (including all amendments) applies. GB/T 3181-2008 Colour standard for paint film GB 6245 Fire pumps GB 7956.1 Fire Fighting Vehicles - Part 1: General Technical Requirements 3 Terms and Definitions The following terms and definitions apply to this document. 3.1 liquid extinguishing agent supply system A system installed on a liquid supply vehicle, mainly consisting of a vehicle-mounted liquid supply pump, suction device, pipelines, and control devices, used for conveying various liquid extinguishing agents other than water. 3.2 vehicle-mounted liquid extinguishing agent supply pump A pump installed on a liquid supply vehicle, used for conveying various liquid extinguishing agents other than water. Note: Abbreviated as "liquid supply pump". 4 Technical Requirements 4.1 Basic Requirements Liquid supply vehicles shall comply with the requirements of GB 7956.1. 4.2 Vehicle Requirements 4.2.1 The fuel tank capacity of the liquid supply vehicle shall be sufficient for all liquid supply pumps to operate continuously for not less than 2 hours at their rated flow and rated pressure after the vehicle has traveled 100 km. 4.2.2 The liquid supply vehicle shall be equipped with an electronic controller for the liquid supply pump speed. This controller shall be capable of stably adjusting the speed of the liquid supply pump(s). 4.2.3 Valves of all automatic control systems on the liquid supply vehicle shall be equipped with emergency manual control devices. 4.2.4 For liquid supply vehicles equipped with a suction device, its operation shall not affect the normal operation of the liquid supply pump(s). The flow rate at which the suction device conveys liquid extinguishing agent into the tank(s) shall not be less than the sum of the rated flow rates of the liquid supply pump(s). 4.2.5 The liquid supply vehicle shall be equipped with an automatic stop device for tank filling. This device shall ensure that external liquid extinguishing agent injection stops automatically once the tank is full. 4.2.6 For liquid supply vehicles equipped with multiple tanks, independent liquid supply pipelines shall be provided for each tank. The operating mechanisms for opening/closing these pipelines shall be distinguishable. 4.2.7 Reliable anti-slip measures shall be provided in the liquid supply system operation area, on the vehicle roof, on flip steps, and on ladder treads-anywhere personnel may stand. 4.2.8 The liquid supply vehicle shall have measures to prevent liquid extinguishing agent, if it overflows from the tank(s), from flowing towards the operation area. 4.2.9 The liquid supply system operation location(s) on the vehicle shall have at least: a display device for each liquid supply pump's outlet pressure, speed, and cumulative operating time; a display for each tank's liquid level; and a display for engine coolant temperature. It shall have at least: an operating device for starting/stopping and speed control of each liquid supply pump; an audible and visual alarm for low liquid level in each tank; an operating device for flushing the liquid supply system; and an emergency stop device. 4.2.10 A pipeline schematic diagram and operating instructions for the liquid supply system shall be provided at the system operation location(s). The rated pressure and rated flow of the liquid supply system and of each liquid supply pump shall be indicated, along with a reminder that the extinguishing agent requires periodic agitation. 4.2.11 All buttons and switches on the liquid supply vehicle shall have operating markings. 4.2.12 Effective warning signs alerting operators to hazards shall be provided at hazardous locations on the liquid supply vehicle, such as high temperature and high-speed rotation, as well as in personnel standing areas where contact with liquid extinguishing agent is possible. 4.2.13 A test connection for measuring liquid supply pump pressure shall be provided at the vehicle's operation panel. The connection shall have an external thread specification of M10×1.5 mm, with a thread length not less than 15 mm. Its location shall facilitate the installation of an external pressure gauge, and it shall have a connection marking. 4.2.14 The liquid supply vehicle shall be supplied with: suction hoses matching the number of liquid supply pumps, each with a single length not less than 3 m; supply hoses with a total length not less than 200 m; a suction hose wrench (if applicable); a supply hose wrench (if applicable); a rubber mallet (if applicable); reducer couplings (if applicable); rubber gloves; and other such equipment. 4.3 Tank Requirements 4.3.1 The tank body and valves shall be made of corrosion-resistant materials. 4.3.2 For tanks with a volume greater than or equal to 12 m³, the volume error shall not exceed ±2%. For tanks with a volume less than 12 m³ but not less than 1 m³, for every 1 m³ decrease in volume, the allowable absolute error increases by 0.1%. For tanks with a volume less than 1 m³, the volume error shall not exceed ±10%. 4.3.3 Tanks with a volume greater than 2 m³ shall be equipped with internal baffles. Tanks with a volume exceeding 3 m³ shall be equipped with longitudinal baffles, and the volume of any single compartment created by the baffles shall not exceed 2 m³. 4.3.4 The structure of each tank and the placement of its outlet shall ensure that the residual rate of liquid extinguishing agent in the tank is not greater than 5%. 4.3.5 For tanks with a volume greater than 1 m³, a manhole and manhole cover allowing personnel entry shall be provided on the top. The manhole diameter shall not be less than 400 mm. 4.3.6 A drain hole shall be provided at the lowest point of the tank. Discharged sediment shall not contact the vehicle body or chassis components. 4.3.7 The tank shall be equipped with an indicating device for liquid level or liquid quantity.
Code of China
Standard
GB 7956.22-2025  Fire fighting vehicle—Part 22:Liquid extinguishing agent supply fire fighting vehicle (English Version)
Standard No.GB 7956.22-2025
Statusto be valid
LanguageEnglish
File FormatPDF
Word Count8500 words
Price(USD)255.0
Implemented on2027-1-1
Deliveryvia email in 1~3 business day
Detail of GB 7956.22-2025
Standard No.
GB 7956.22-2025
English Name
Fire fighting vehicle—Part 22:Liquid extinguishing agent supply fire fighting vehicle
Chinese Name
消防车 第22部分:供液消防车
Chinese Classification
Professional Classification
GB
ICS Classification
Issued by
SAMR;SAC
Issued on
2025-12-02
Implemented on
2027-1-1
Status
to be valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
8500 words
Price(USD)
255.0
Keywords
GB 7956.22-2025, GB/T 7956.22-2025, GBT 7956.22-2025, GB7956.22-2025, GB 7956.22, GB7956.22, GB/T7956.22-2025, GB/T 7956.22, GB/T7956.22, GBT7956.22-2025, GBT 7956.22, GBT7956.22
Introduction of GB 7956.22-2025
GB 7956.22-2025 Fire fighting vehicle—Part 22:Liquid extinguishing agent supply fire fighting vehicle English, Anglais, Englisch, Inglés, えいご This is a draft translation for reference among interesting stakeholders. The finalized translation (passing through draft translation, self-check, revision and verification) will be delivered upon being ordered. ICS CCS H National Standard of the People's Republic of China ‌GB 7956.22-2025 Fire fighting vehicles - Part 22: Liquid extinguishing agent supply fire fighting vehicle 消防车 第22部分:供液消防车 Issue date: 2025-12-02 Implementation date: 2027-01-01 Issued by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China the Standardization Administration of the People's Republic of China Contents Foreword 1 Scope 2 Normative References 3 Terms and Definitions 4 Technical Requirements 4.1 Basic Requirements 4.2 Vehicle Requirements 4.3 Chassis Modification Requirements 4.4 Marking Requirements 4.5 Firefighting Hydraulic System Requirements 4.6 Hydraulic System Requirements 4.7 Control Cabinet Requirements 4.8 Turbo-jet Extinguishing Device Requirements 4.9 Requirements for Accompanying Documentation, Tools, and Wear Parts 5 Test Methods 5.1 Basic Requirements Tests 5.2 Vehicle Requirements Tests 5.3 Tests for Chassis Modification Requirements 5.4 Marking Inspection 5.5 Firefighting Hydraulic System Tests 5.6 Hydraulic System Tests 5.7 Control Cabinet Tests 5.8 Turbo-jet Extinguishing Device Tests 5.9 Inspection of Accompanying Documentation, Tools, and Wear Parts 6 Inspection Rules 6.1 Types of Inspection 6.2 Decision Rules 7 Packaging, Transportation, and Storage 7.1 Packaging 7.2 Transportation 7.3 Storage Fire Fighting Vehicles - Part 22: Liquid Extinguishing Agent Supply Fire Fighting Vehicles 1 Scope This document specifies the technical requirements, inspection rules, packaging, transportation, and storage requirements for liquid extinguishing agent supply fire fighting vehicles, and describes the relevant test methods. This document is applicable to the design, manufacture, and inspection of liquid extinguishing agent supply fire fighting vehicles (hereinafter referred to as "liquid supply vehicles"). 2 Normative References The contents of the following documents constitute indispensable clauses of this document through normative reference. For dated references, only the edition corresponding to the date applies. For undated references, the latest edition (including all amendments) applies. GB/T 3181-2008 Colour standard for paint film GB 6245 Fire pumps GB 7956.1 Fire Fighting Vehicles - Part 1: General Technical Requirements 3 Terms and Definitions The following terms and definitions apply to this document. 3.1 liquid extinguishing agent supply system A system installed on a liquid supply vehicle, mainly consisting of a vehicle-mounted liquid supply pump, suction device, pipelines, and control devices, used for conveying various liquid extinguishing agents other than water. 3.2 vehicle-mounted liquid extinguishing agent supply pump A pump installed on a liquid supply vehicle, used for conveying various liquid extinguishing agents other than water. Note: Abbreviated as "liquid supply pump". 4 Technical Requirements 4.1 Basic Requirements Liquid supply vehicles shall comply with the requirements of GB 7956.1. 4.2 Vehicle Requirements 4.2.1 The fuel tank capacity of the liquid supply vehicle shall be sufficient for all liquid supply pumps to operate continuously for not less than 2 hours at their rated flow and rated pressure after the vehicle has traveled 100 km. 4.2.2 The liquid supply vehicle shall be equipped with an electronic controller for the liquid supply pump speed. This controller shall be capable of stably adjusting the speed of the liquid supply pump(s). 4.2.3 Valves of all automatic control systems on the liquid supply vehicle shall be equipped with emergency manual control devices. 4.2.4 For liquid supply vehicles equipped with a suction device, its operation shall not affect the normal operation of the liquid supply pump(s). The flow rate at which the suction device conveys liquid extinguishing agent into the tank(s) shall not be less than the sum of the rated flow rates of the liquid supply pump(s). 4.2.5 The liquid supply vehicle shall be equipped with an automatic stop device for tank filling. This device shall ensure that external liquid extinguishing agent injection stops automatically once the tank is full. 4.2.6 For liquid supply vehicles equipped with multiple tanks, independent liquid supply pipelines shall be provided for each tank. The operating mechanisms for opening/closing these pipelines shall be distinguishable. 4.2.7 Reliable anti-slip measures shall be provided in the liquid supply system operation area, on the vehicle roof, on flip steps, and on ladder treads-anywhere personnel may stand. 4.2.8 The liquid supply vehicle shall have measures to prevent liquid extinguishing agent, if it overflows from the tank(s), from flowing towards the operation area. 4.2.9 The liquid supply system operation location(s) on the vehicle shall have at least: a display device for each liquid supply pump's outlet pressure, speed, and cumulative operating time; a display for each tank's liquid level; and a display for engine coolant temperature. It shall have at least: an operating device for starting/stopping and speed control of each liquid supply pump; an audible and visual alarm for low liquid level in each tank; an operating device for flushing the liquid supply system; and an emergency stop device. 4.2.10 A pipeline schematic diagram and operating instructions for the liquid supply system shall be provided at the system operation location(s). The rated pressure and rated flow of the liquid supply system and of each liquid supply pump shall be indicated, along with a reminder that the extinguishing agent requires periodic agitation. 4.2.11 All buttons and switches on the liquid supply vehicle shall have operating markings. 4.2.12 Effective warning signs alerting operators to hazards shall be provided at hazardous locations on the liquid supply vehicle, such as high temperature and high-speed rotation, as well as in personnel standing areas where contact with liquid extinguishing agent is possible. 4.2.13 A test connection for measuring liquid supply pump pressure shall be provided at the vehicle's operation panel. The connection shall have an external thread specification of M10×1.5 mm, with a thread length not less than 15 mm. Its location shall facilitate the installation of an external pressure gauge, and it shall have a connection marking. 4.2.14 The liquid supply vehicle shall be supplied with: suction hoses matching the number of liquid supply pumps, each with a single length not less than 3 m; supply hoses with a total length not less than 200 m; a suction hose wrench (if applicable); a supply hose wrench (if applicable); a rubber mallet (if applicable); reducer couplings (if applicable); rubber gloves; and other such equipment. 4.3 Tank Requirements 4.3.1 The tank body and valves shall be made of corrosion-resistant materials. 4.3.2 For tanks with a volume greater than or equal to 12 m³, the volume error shall not exceed ±2%. For tanks with a volume less than 12 m³ but not less than 1 m³, for every 1 m³ decrease in volume, the allowable absolute error increases by 0.1%. For tanks with a volume less than 1 m³, the volume error shall not exceed ±10%. 4.3.3 Tanks with a volume greater than 2 m³ shall be equipped with internal baffles. Tanks with a volume exceeding 3 m³ shall be equipped with longitudinal baffles, and the volume of any single compartment created by the baffles shall not exceed 2 m³. 4.3.4 The structure of each tank and the placement of its outlet shall ensure that the residual rate of liquid extinguishing agent in the tank is not greater than 5%. 4.3.5 For tanks with a volume greater than 1 m³, a manhole and manhole cover allowing personnel entry shall be provided on the top. The manhole diameter shall not be less than 400 mm. 4.3.6 A drain hole shall be provided at the lowest point of the tank. Discharged sediment shall not contact the vehicle body or chassis components. 4.3.7 The tank shall be equipped with an indicating device for liquid level or liquid quantity.
Contents of GB 7956.22-2025
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Contact us via WeChat
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 3680948734
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 7956.22-2025, GB/T 7956.22-2025, GBT 7956.22-2025, GB7956.22-2025, GB 7956.22, GB7956.22, GB/T7956.22-2025, GB/T 7956.22, GB/T7956.22, GBT7956.22-2025, GBT 7956.22, GBT7956.22