2023-1-28 35.173.35.14
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB/T 12726.4-2013
GB/T 12726.4-2013   Nuclear power plants—Instrumentation important to safety—Radiation monitoring for accident and post-accident conditions—Part 4:Equipment for continuous in-line or on-line monitoring of radioactivity in process streams (English Version)
Standard No.: GB/T 12726.4-2013 Status:valid remind me the status change

Email:

Language:English File Format:PDF
Word Count: 4000 words Price(USD):100.0 remind me the price change

Email:

Implemented on:2014-8-1 Delivery: via email in 1 business day
,,
Standard No.: GB/T 12726.4-2013
English Name: Nuclear power plants—Instrumentation important to safety—Radiation monitoring for accident and post-accident conditions—Part 4:Equipment for continuous in-line or on-line monitoring of radioactivity in process streams
Chinese Name: 核电厂安全重要仪表 事故及事故后辐射监测 第4部分:工艺流管内或管旁放射性连续监测设备
Chinese Classification: F69    Nuclear reactor and nuclear island equipment of nuclear power plant
Professional Classification: GB    National Standard
ICS Classification: 27.120.20 27.120.20    Nuclear power plants. Safety 27.120.20
Issued by: AQSIQ, SAC
Issued on: 2013-12-17
Implemented on: 2014-8-1
Status: valid
Superseding:GB/T 12726.4-1995 Radiation monitoring equipment for accident and postaccident conditions in nuclear power plants-Part 4: Process stream radiation monitor
Language: English
File Format: PDF
Word Count: 4000 words
Price(USD): 100.0
Delivery: via email in 1 business day
GB/T 12726 "Nuclear Power Plants — Instrumentation Important to Safety — Radiation Monitoring for Accident and Post-accident Conditions" is comprised of 4 parts: — Part 1: General Requirements; — Part 2: Equipment for Continuous Off-line Monitoring of Radioactivity in Gaseous Effluents and Ventilation Air; — Part 3: Equipment for Continuous High Range Area Gamma Monitoring; — Part 4: Equipment for Continuous In-line or On-line Monitoring of Radioactivity in Process Streams. This part is Part 4 of GB/T 12726. 1 Scope This part of GB/T 12726 specifies general guidance on the design principles and performance criteria for equipment for continuous in-line or on-line monitoring of radioactivity in process stream in nuclear power plants for accident and post-accident conditions. General requirements for technical characteristics, test procedures, radiation characteristics, electrical, mechanical, and environmental characteristics are given in GB/T 12726.1-2013. These requirements are applicable in this part unless otherwise stated. This part is only applicable to continuous in-line or on-line measurement, i.e. monitors for which the detector measures radioactivity by being positioned in the process stream (i.e. immerged in) or adjacent to the process stream (i.e. viewing straight through a pipe or tank). It does not apply to monitors for which the detector measures a representative proportion of the stream at some remote location (sampling assembly), which are within the scope of GB/T 12726.2. This part is only applicable to monitors for accident and post-accident conditions. Process stream radiation monitoring equipment for normal and incident conditions are within the scope of IEC 60768. 2 Normative References The following documents are indispensable for the application of this document. For dated references, only the dated editions apply. For undated references, the latest editions (including any amendments) apply. GB/T 2423.3-2006 Environmental Testing for Electric and Electronic Products — Part 2: Tests Methods — Test Cab: Damp Heat Steady State (IEC 60068-2-78:2001, IDT) GB/T 2423.4-2008 Environmental Testing for Electric and Electronic Products — Part 2: Tests Methods — Test Db: Damp Heat, Cyclic (12h+12h Cycle) (IEC 60068-2-30:2005, IDT) GB/T 12726.1-2013 Nuclear Power Plants — Instrumentation Important to Safety — Radiation Monitoring for Accident and Post-accident Conditions — Part 1: General Requirements (IEC 60951-1:2009, IDT) IEC 60768 Nuclear Power Plants — Instrumentation Important to Safety — Equipment for Continuous In-line or On-line Monitoring of Radioactivity in Process Streams for Normal and Incident Conditions 3 Terms and Definitions For the purposes of this document, the terms and definitions given in GB/T 12726.1-2013 apply. 4 Design Principles
Foreword II Introduction III 1 Scope 2 Normative References 3 Terms and Definitions 4 Design Principles 4.1 General 4.2 Basic requirements related to functions 4.3 Range of measurement 4.4 In-line detectors mechanical features 5 Functional Testing 5.1 General 5.2 Environmental performance test Table 1 Standards of SAC/TC 30/SC 2/SC 3 IV Table 2 Additional Tests to Complement the General Tests Required in GB/T 12726.1-2013
Code of China
Standard
GB/T 12726.4-2013  Nuclear power plants—Instrumentation important to safety—Radiation monitoring for accident and post-accident conditions—Part 4:Equipment for continuous in-line or on-line monitoring of radioactivity in process streams (English Version)
Standard No.GB/T 12726.4-2013
Statusvalid
LanguageEnglish
File FormatPDF
Word Count4000 words
Price(USD)100.0
Implemented on2014-8-1
Deliveryvia email in 1 business day
Detail of GB/T 12726.4-2013
Standard No.
GB/T 12726.4-2013
English Name
Nuclear power plants—Instrumentation important to safety—Radiation monitoring for accident and post-accident conditions—Part 4:Equipment for continuous in-line or on-line monitoring of radioactivity in process streams
Chinese Name
核电厂安全重要仪表 事故及事故后辐射监测 第4部分:工艺流管内或管旁放射性连续监测设备
Chinese Classification
F69
Professional Classification
GB
ICS Classification
Issued by
AQSIQ, SAC
Issued on
2013-12-17
Implemented on
2014-8-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
GB/T 12726.4-1995 Radiation monitoring equipment for accident and postaccident conditions in nuclear power plants-Part 4: Process stream radiation monitor
Language
English
File Format
PDF
Word Count
4000 words
Price(USD)
100.0
Keywords
GB/T 12726.4-2013, GB 12726.4-2013, GBT 12726.4-2013, GB/T12726.4-2013, GB/T 12726.4, GB/T12726.4, GB12726.4-2013, GB 12726.4, GB12726.4, GBT12726.4-2013, GBT 12726.4, GBT12726.4
Introduction of GB/T 12726.4-2013
GB/T 12726 "Nuclear Power Plants — Instrumentation Important to Safety — Radiation Monitoring for Accident and Post-accident Conditions" is comprised of 4 parts: — Part 1: General Requirements; — Part 2: Equipment for Continuous Off-line Monitoring of Radioactivity in Gaseous Effluents and Ventilation Air; — Part 3: Equipment for Continuous High Range Area Gamma Monitoring; — Part 4: Equipment for Continuous In-line or On-line Monitoring of Radioactivity in Process Streams. This part is Part 4 of GB/T 12726. 1 Scope This part of GB/T 12726 specifies general guidance on the design principles and performance criteria for equipment for continuous in-line or on-line monitoring of radioactivity in process stream in nuclear power plants for accident and post-accident conditions. General requirements for technical characteristics, test procedures, radiation characteristics, electrical, mechanical, and environmental characteristics are given in GB/T 12726.1-2013. These requirements are applicable in this part unless otherwise stated. This part is only applicable to continuous in-line or on-line measurement, i.e. monitors for which the detector measures radioactivity by being positioned in the process stream (i.e. immerged in) or adjacent to the process stream (i.e. viewing straight through a pipe or tank). It does not apply to monitors for which the detector measures a representative proportion of the stream at some remote location (sampling assembly), which are within the scope of GB/T 12726.2. This part is only applicable to monitors for accident and post-accident conditions. Process stream radiation monitoring equipment for normal and incident conditions are within the scope of IEC 60768. 2 Normative References The following documents are indispensable for the application of this document. For dated references, only the dated editions apply. For undated references, the latest editions (including any amendments) apply. GB/T 2423.3-2006 Environmental Testing for Electric and Electronic Products — Part 2: Tests Methods — Test Cab: Damp Heat Steady State (IEC 60068-2-78:2001, IDT) GB/T 2423.4-2008 Environmental Testing for Electric and Electronic Products — Part 2: Tests Methods — Test Db: Damp Heat, Cyclic (12h+12h Cycle) (IEC 60068-2-30:2005, IDT) GB/T 12726.1-2013 Nuclear Power Plants — Instrumentation Important to Safety — Radiation Monitoring for Accident and Post-accident Conditions — Part 1: General Requirements (IEC 60951-1:2009, IDT) IEC 60768 Nuclear Power Plants — Instrumentation Important to Safety — Equipment for Continuous In-line or On-line Monitoring of Radioactivity in Process Streams for Normal and Incident Conditions 3 Terms and Definitions For the purposes of this document, the terms and definitions given in GB/T 12726.1-2013 apply. 4 Design Principles
Contents of GB/T 12726.4-2013
Foreword II Introduction III 1 Scope 2 Normative References 3 Terms and Definitions 4 Design Principles 4.1 General 4.2 Basic requirements related to functions 4.3 Range of measurement 4.4 In-line detectors mechanical features 5 Functional Testing 5.1 General 5.2 Environmental performance test Table 1 Standards of SAC/TC 30/SC 2/SC 3 IV Table 2 Additional Tests to Complement the General Tests Required in GB/T 12726.1-2013
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Foryou Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 12726.4-2013, GB 12726.4-2013, GBT 12726.4-2013, GB/T12726.4-2013, GB/T 12726.4, GB/T12726.4, GB12726.4-2013, GB 12726.4, GB12726.4, GBT12726.4-2013, GBT 12726.4, GBT12726.4