1 General
Fuse-links for the protection of battery energy systems shall comply with aIl requirements of IEC 60269-1 , if not otherwise indicated hereinafter, and shall also comply with the
supplementary requirements laid down below.
1.1 Scope and object
These supplementary requirements apply to fuse-links for the protection of batteries and battery systems, including, but not limited to terminology, for electricity storage in equipment for circuits of nominal voltages up to 1500 V DC.
Their rated voltage can be higher than 1500 V DC.
The object of these supplementary requirements is to establish the characteristics of battery fuse-links in such a way that they can be replaced by other fuse-links having the same characteristics, provided that their dimensions are identical.
1.2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies.For undated references, the latest edition of the referenced document (including any amendments) applies.
ISO/IEC 17025 General requirements for the competence of testing and calibration laboratories
Note: GB/T 27025-2019, General requirements for the competence oftesting and calibration laboratories (ISO/IEC 17025:2017, IDT)
IEC 60269-1 Low-voltage fuses - Part 1: General requirements
Note: GB/T 13539.1-2015, Low-voltage fuses - Part 1: General requirements (IEC 60269-1:2009, IDT)
IEC 60417 Graphical symbols for use on equipment
Note1: GB/T 5465.1-2009, Graphical symbols for use on electrical equipment - Part 1: Overview and classification (IEC 60417, Database:2007-01, MOD)
Note2: GB/T 5465.2-2008, Graphical symbols for use on electrical equipment - Part 2 : Graphical symbols (IEC 60417DB:2007, IDT)
IECEE OD-5014 IEC System of Conformity Assessment Schemes for Electrotechnical Equipment and Components (IECEE System), Committee of Testing Laboratories (CTL), Instrument Accuracy Limits
2 Terms and definitions
For the purposes of this document, the terms and definitions given in IEC 60269-1 and the
following apply.
ISO and IEC maintain terminological databases for use in standardization at the following
addresses:
——IEC Electropedia: available at http://www.electropedia.org/
——ISO Online browsing platform: available at http://www.iso.org/obp
2.1 General terms
2.1.101
battery
one or more cells fitted with devices necessary for use, for example case, terminals, markings and protective devices etc., as necessary for use
[SOURCE: IEC 60050-482:2004, 482-01-04, modified.]
2.1.102
cell
basic functional unit, consisting of an assembly of electrodes, electrolyte, container, terminals and usually separators, that is a source of electric energy obtained by direct conversion of chemical energy
[SOURCE: IEC 60050-482:2004, 482-01-01, modified.]
2.1.103
battery module
group of cells connected together, either in a series and/or parallel configuration with or without protective devices (e.g. fuse or PTC: Positive Temperature Coefficient) and monitoring circuitry
2.1.104
battery system
battery system which incorporates one or more cells, modules or battery packs including
associated devices
Note 1: It has battery management unit to cut off in case of overcharging, over current, and overheating. It may have cooling or heating units.
2.1.105
rated energy
quantity of energy, declared by the manufacturer, which under the specified conditions can be discharged from fully charged flow battery energy storage system, to fully discharge
Note 1: The rated energy is expressed in watt hour (Wh).
2.1.106
rated output power
electrical power, declared by the manufacturer, which under the specified operating conditions is the maximum output power designed to be achieved
Note 1: The rated output power is normally expressed in watt (W).
2.1.107
short-circuit current
maximum current which can be delivered by a cell or battery into an external circuit with zero electric resistance, or an external circuit which depresses the cell or battery voltage to approximately zero volts
[SOURCE: IEC 60050-482:2004, 482-03-26, modified.]
2.1.108
open circuit voltage OCV
off-load voltage
Uoc
voltage across the terminals of a cell or battery when no external current is flowing
[SOURCE: IEC 60050-482:2004, 482-03-32, modified.]
2.1.109
overcurrent protective device
device provided to interrupt an electrical circuit in case the conductor current in the electrical circuit exceeds a predetermined value for a specified duration
2.1.110
rated capacity
capacity value of a cell or battery determined under specified conditions and declared by the manufacturer
[SOURCE: IEC 60050-482:2004, 482-03-15, modified.]
Standard
GB/T 13539.7-2024 Low voltage fuses—Part 7: Supplementary requirements for fuse-links for the protection of batteries and battery systems (English Version)
Standard No.
GB/T 13539.7-2024
Status
valid
Language
English
File Format
PDF
Word Count
10500 words
Price(USD)
315.0
Implemented on
2024-11-1
Delivery
via email in 1~3 business day
Detail of GB/T 13539.7-2024
Standard No.
GB/T 13539.7-2024
English Name
Low voltage fuses—Part 7: Supplementary requirements for fuse-links for the protection of batteries and battery systems
GB/T 13539.7-2024 Low Voltage Fuses - Part 7: Supplementary Requirements for fuse-links for the protection of batteries and battery systems
1 General
Fuse-links for the protection of battery energy systems shall comply with aIl requirements of IEC 60269-1 , if not otherwise indicated hereinafter, and shall also comply with the
supplementary requirements laid down below.
1.1 Scope and object
These supplementary requirements apply to fuse-links for the protection of batteries and battery systems, including, but not limited to terminology, for electricity storage in equipment for circuits of nominal voltages up to 1500 V DC.
Their rated voltage can be higher than 1500 V DC.
The object of these supplementary requirements is to establish the characteristics of battery fuse-links in such a way that they can be replaced by other fuse-links having the same characteristics, provided that their dimensions are identical.
1.2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies.For undated references, the latest edition of the referenced document (including any amendments) applies.
ISO/IEC 17025 General requirements for the competence of testing and calibration laboratories
Note: GB/T 27025-2019, General requirements for the competence oftesting and calibration laboratories (ISO/IEC 17025:2017, IDT)
IEC 60269-1 Low-voltage fuses - Part 1: General requirements
Note: GB/T 13539.1-2015, Low-voltage fuses - Part 1: General requirements (IEC 60269-1:2009, IDT)
IEC 60417 Graphical symbols for use on equipment
Note1: GB/T 5465.1-2009, Graphical symbols for use on electrical equipment - Part 1: Overview and classification (IEC 60417, Database:2007-01, MOD)
Note2: GB/T 5465.2-2008, Graphical symbols for use on electrical equipment - Part 2 : Graphical symbols (IEC 60417DB:2007, IDT)
IECEE OD-5014 IEC System of Conformity Assessment Schemes for Electrotechnical Equipment and Components (IECEE System), Committee of Testing Laboratories (CTL), Instrument Accuracy Limits
2 Terms and definitions
For the purposes of this document, the terms and definitions given in IEC 60269-1 and the
following apply.
ISO and IEC maintain terminological databases for use in standardization at the following
addresses:
——IEC Electropedia: available at http://www.electropedia.org/
——ISO Online browsing platform: available at http://www.iso.org/obp
2.1 General terms
2.1.101
battery
one or more cells fitted with devices necessary for use, for example case, terminals, markings and protective devices etc., as necessary for use
[SOURCE: IEC 60050-482:2004, 482-01-04, modified.]
2.1.102
cell
basic functional unit, consisting of an assembly of electrodes, electrolyte, container, terminals and usually separators, that is a source of electric energy obtained by direct conversion of chemical energy
[SOURCE: IEC 60050-482:2004, 482-01-01, modified.]
2.1.103
battery module
group of cells connected together, either in a series and/or parallel configuration with or without protective devices (e.g. fuse or PTC: Positive Temperature Coefficient) and monitoring circuitry
2.1.104
battery system
battery system which incorporates one or more cells, modules or battery packs including
associated devices
Note 1: It has battery management unit to cut off in case of overcharging, over current, and overheating. It may have cooling or heating units.
2.1.105
rated energy
quantity of energy, declared by the manufacturer, which under the specified conditions can be discharged from fully charged flow battery energy storage system, to fully discharge
Note 1: The rated energy is expressed in watt hour (Wh).
2.1.106
rated output power
electrical power, declared by the manufacturer, which under the specified operating conditions is the maximum output power designed to be achieved
Note 1: The rated output power is normally expressed in watt (W).
2.1.107
short-circuit current
maximum current which can be delivered by a cell or battery into an external circuit with zero electric resistance, or an external circuit which depresses the cell or battery voltage to approximately zero volts
[SOURCE: IEC 60050-482:2004, 482-03-26, modified.]
2.1.108
open circuit voltage OCV
off-load voltage
Uoc
voltage across the terminals of a cell or battery when no external current is flowing
[SOURCE: IEC 60050-482:2004, 482-03-32, modified.]
2.1.109
overcurrent protective device
device provided to interrupt an electrical circuit in case the conductor current in the electrical circuit exceeds a predetermined value for a specified duration
2.1.110
rated capacity
capacity value of a cell or battery determined under specified conditions and declared by the manufacturer
[SOURCE: IEC 60050-482:2004, 482-03-15, modified.]