2025-12-14 216.73.216.3
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB/T 16150-2025
GB/T 16150-2025   Determination method of sieve analysis for pesticides (English Version)
Standard No.: GB/T 16150-2025 Status:to be valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 5500 words Translation Price(USD):165.0 remind me the price change

Email:

Implemented on:2026-3-1 Delivery: via email in 1~3 business day

→ → →

,,2026-3-1,5B00E27A2AF05BD11756957392382
Standard No.: GB/T 16150-2025
English Name: Determination method of sieve analysis for pesticides
Chinese Name: 农药筛析试验方法
Chinese Classification: G23    Basic standards and general methods for pesticides
Professional Classification: GB    National Standard
Source Content Issued by: SAMR; SAC
Issued on: 2025-8-29
Implemented on: 2026-3-1
Status: to be valid
Superseding:GB/T 16150-1995 Seive test for dustable and wettable powders of pesticides
Target Language: English
File Format: PDF
Word Count: 5500 words
Translation Price(USD): 165.0
Delivery: via email in 1~3 business day
GB/T 16150-2025 Determination method of sieve analysis for pesticides English, Anglais, Englisch, Inglés, えいご This is a draft translation for reference among interesting stakeholders. The finalized translation (passing through draft translation, self-check, revision and verification) will be delivered upon being ordered. ICS 13.340.01 CCS H 57 National Standard of the People's Republic of China ‌GB/T 16150-2025 Replaces GB/T 16150-1995 Determination method of sieve analysis for pesticides Issue date: 2025-08-29 Implementation date: 2026-03-01 Issued by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China the Standardization Administration of the People's Republic of China Contents‌ Foreword 1 Scope 2 Normative References 3 Terms and Definitions ‌4 Test Methods 5 Test Samples 6 Test Conditions 7 Test Procedure References Determination method of sieve analysis for pesticides‌ ‌Warning:‌ Personnel using this document shall have practical laboratory experience. This document does not address all safety issues. Users are responsible for implementing appropriate safety and health measures. ‌1 Scope‌ This document describes the sieve analysis test methods for pesticides. ‌Wet sieving test‌: applicable to the determination of passing rate for dispersible tablets, soluble tablets, wettable powders, emulifiable powders, granule suspensions, water-dispersible granules, dispersible liquid concentrates, oil-based suspensions, microcapsule suspensions, microcapsule suspension-emulsions, microcapsule suspension-suspensions, microcapsule suspension-emulsion-suspensions, suspension concentrates, seed treatment wettable powders, and seed treatment suspension concentrates. ‌Dry sieving test‌: applicable to the determination of passing rate for powder formulations and seed treatment dry powders. ‌Particle size range‌: applicable to the determination of particle size in granular formulations. ‌2 Normative References‌ This document contains no normative references. ‌3 Terms and Definitions‌ No terms or definitions are defined in this document. ‌4 Test Methods‌ ‌4.1 Wet Sieving Test‌ ‌4.1.1 Principle‌ Weigh the sample, wet it in a beaker, and stir. Transfer the wetted sample to a test sieve, rinse with a gentle stream of tap water, and collect the residue on a watch glass. Dry the residue, weigh it, and calculate the passing rate. ‌4.1.2 Apparatus and Materials‌ ‌Test sieve‌: 20 cm diameter, 75 μm aperture. ‌Magnetic stirrer‌. ‌Magnetic stirrer bar‌: ~2 cm length. ‌Drying oven‌: temperature control ±2°C. ‌Balance‌: 0.01 g and 0.0001 g precision. ‌Beaker‌: 250 mL. ‌Rubber hose‌: 10 mm inner diameter. ‌Watch glass‌: 12 cm diameter. ‌Desiccator‌. ‌4.1.3 Procedure‌ ‌4.1.3.1 General Conditions‌ Conduct all operations at ambient temperature (25°C ±5°C). ‌4.1.3.2 Sample Wetting‌ Weigh 10 g (0.01 g precision) of sample into a 250 mL beaker. Add 100 mL tap water, let stand for 60 s, then stir for 5 min using a magnetic stirrer. ‌4.1.3.3 Wet Sieving‌ Transfer the wetted sample to the test sieve and rinse with tap water. Use a gentle stream of tap water (1–5 L/min, 2–5 cm above the sieve surface) to rinse the residue for up to 10 min until no further residue is visible. If no residue remains, record a passing rate of 100%. If residue is present, transfer it to a pre-weighed watch glass using deionized water. Dry at 70°C (or an appropriate temperature based on product properties) until constant weight. Cool in a desiccator, weigh (0.0001 g precision), and calculate the passing rate using formula (1): where: w1w1​: Passing rate of wet sieving test (%); m1m1​: Mass of sample (g); m2m2​: Mass of residue (g). ‌4.1.3.4 Permissible Difference‌ The difference between duplicate results shall not exceed 0.5%. Report the arithmetic mean as the final result. ‌4.2 Dry Sieving Test‌ ‌4.2.1 Principle‌ Weigh a sample, sieve it through a test sieve until the residue mass stabilizes, and calculate the passing rate based on the mass passing through. ‌4.2.2 Apparatus and Materials‌ ‌Test sieve‌: 20 cm diameter, 75 μm aperture (or other sizes), with a receiving pan and lid. ‌Vibratory sieve shaker (for shaker method)‌: tray diameter ≥20 cm, amplitude 4 mm, frequency 300 rpm. ‌Balance‌: 0.01 g precision. ‌Soft brush‌: 2.5 cm flat brush. ‌Stiff brush‌. ‌Iron stand (for manual sieving).‌ ‌Metal rod (for manual sieving)‌: 1 cm diameter, 10 cm length. ‌Rubber plate (for manual sieving)‌: 20 cm × 20 cm, hardness 35–40 IRHD (or equivalent). ‌4.2.3 Procedure‌ ‌4.2.3.1 Shaker Method (Arbitration Method)‌ Install the test sieve on the shaker. Weigh 20 g (0.01 g precision) of sample into the sieve. Vibrate for 5 min, allow dust to settle for 2 min, then weigh the material in the receiving pan (m3m3​). ‌4.2.3.2 Manual Sieving Method‌
Code of China
Standard
GB/T 16150-2025  Determination method of sieve analysis for pesticides (English Version)
Standard No.GB/T 16150-2025
Statusto be valid
LanguageEnglish
File FormatPDF
Word Count5500 words
Price(USD)165.0
Implemented on2026-3-1
Deliveryvia email in 1~3 business day
Detail of GB/T 16150-2025
Standard No.
GB/T 16150-2025
English Name
Determination method of sieve analysis for pesticides
Chinese Name
农药筛析试验方法
Chinese Classification
G23
Professional Classification
GB
ICS Classification
Issued by
SAMR; SAC
Issued on
2025-8-29
Implemented on
2026-3-1
Status
to be valid
Superseded by
Superseded on
Abolished on
Superseding
GB/T 16150-1995 Seive test for dustable and wettable powders of pesticides
Language
English
File Format
PDF
Word Count
5500 words
Price(USD)
165.0
Keywords
GB/T 16150-2025, GB 16150-2025, GBT 16150-2025, GB/T16150-2025, GB/T 16150, GB/T16150, GB16150-2025, GB 16150, GB16150, GBT16150-2025, GBT 16150, GBT16150
Introduction of GB/T 16150-2025
GB/T 16150-2025 Determination method of sieve analysis for pesticides English, Anglais, Englisch, Inglés, えいご This is a draft translation for reference among interesting stakeholders. The finalized translation (passing through draft translation, self-check, revision and verification) will be delivered upon being ordered. ICS 13.340.01 CCS H 57 National Standard of the People's Republic of China ‌GB/T 16150-2025 Replaces GB/T 16150-1995 Determination method of sieve analysis for pesticides Issue date: 2025-08-29 Implementation date: 2026-03-01 Issued by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China the Standardization Administration of the People's Republic of China Contents‌ Foreword 1 Scope 2 Normative References 3 Terms and Definitions ‌4 Test Methods 5 Test Samples 6 Test Conditions 7 Test Procedure References Determination method of sieve analysis for pesticides‌ ‌Warning:‌ Personnel using this document shall have practical laboratory experience. This document does not address all safety issues. Users are responsible for implementing appropriate safety and health measures. ‌1 Scope‌ This document describes the sieve analysis test methods for pesticides. ‌Wet sieving test‌: applicable to the determination of passing rate for dispersible tablets, soluble tablets, wettable powders, emulifiable powders, granule suspensions, water-dispersible granules, dispersible liquid concentrates, oil-based suspensions, microcapsule suspensions, microcapsule suspension-emulsions, microcapsule suspension-suspensions, microcapsule suspension-emulsion-suspensions, suspension concentrates, seed treatment wettable powders, and seed treatment suspension concentrates. ‌Dry sieving test‌: applicable to the determination of passing rate for powder formulations and seed treatment dry powders. ‌Particle size range‌: applicable to the determination of particle size in granular formulations. ‌2 Normative References‌ This document contains no normative references. ‌3 Terms and Definitions‌ No terms or definitions are defined in this document. ‌4 Test Methods‌ ‌4.1 Wet Sieving Test‌ ‌4.1.1 Principle‌ Weigh the sample, wet it in a beaker, and stir. Transfer the wetted sample to a test sieve, rinse with a gentle stream of tap water, and collect the residue on a watch glass. Dry the residue, weigh it, and calculate the passing rate. ‌4.1.2 Apparatus and Materials‌ ‌Test sieve‌: 20 cm diameter, 75 μm aperture. ‌Magnetic stirrer‌. ‌Magnetic stirrer bar‌: ~2 cm length. ‌Drying oven‌: temperature control ±2°C. ‌Balance‌: 0.01 g and 0.0001 g precision. ‌Beaker‌: 250 mL. ‌Rubber hose‌: 10 mm inner diameter. ‌Watch glass‌: 12 cm diameter. ‌Desiccator‌. ‌4.1.3 Procedure‌ ‌4.1.3.1 General Conditions‌ Conduct all operations at ambient temperature (25°C ±5°C). ‌4.1.3.2 Sample Wetting‌ Weigh 10 g (0.01 g precision) of sample into a 250 mL beaker. Add 100 mL tap water, let stand for 60 s, then stir for 5 min using a magnetic stirrer. ‌4.1.3.3 Wet Sieving‌ Transfer the wetted sample to the test sieve and rinse with tap water. Use a gentle stream of tap water (1–5 L/min, 2–5 cm above the sieve surface) to rinse the residue for up to 10 min until no further residue is visible. If no residue remains, record a passing rate of 100%. If residue is present, transfer it to a pre-weighed watch glass using deionized water. Dry at 70°C (or an appropriate temperature based on product properties) until constant weight. Cool in a desiccator, weigh (0.0001 g precision), and calculate the passing rate using formula (1): where: w1w1​: Passing rate of wet sieving test (%); m1m1​: Mass of sample (g); m2m2​: Mass of residue (g). ‌4.1.3.4 Permissible Difference‌ The difference between duplicate results shall not exceed 0.5%. Report the arithmetic mean as the final result. ‌4.2 Dry Sieving Test‌ ‌4.2.1 Principle‌ Weigh a sample, sieve it through a test sieve until the residue mass stabilizes, and calculate the passing rate based on the mass passing through. ‌4.2.2 Apparatus and Materials‌ ‌Test sieve‌: 20 cm diameter, 75 μm aperture (or other sizes), with a receiving pan and lid. ‌Vibratory sieve shaker (for shaker method)‌: tray diameter ≥20 cm, amplitude 4 mm, frequency 300 rpm. ‌Balance‌: 0.01 g precision. ‌Soft brush‌: 2.5 cm flat brush. ‌Stiff brush‌. ‌Iron stand (for manual sieving).‌ ‌Metal rod (for manual sieving)‌: 1 cm diameter, 10 cm length. ‌Rubber plate (for manual sieving)‌: 20 cm × 20 cm, hardness 35–40 IRHD (or equivalent). ‌4.2.3 Procedure‌ ‌4.2.3.1 Shaker Method (Arbitration Method)‌ Install the test sieve on the shaker. Weigh 20 g (0.01 g precision) of sample into the sieve. Vibrate for 5 min, allow dust to settle for 2 min, then weigh the material in the receiving pan (m3m3​). ‌4.2.3.2 Manual Sieving Method‌
Contents of GB/T 16150-2025
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 16150-2025, GB 16150-2025, GBT 16150-2025, GB/T16150-2025, GB/T 16150, GB/T16150, GB16150-2025, GB 16150, GB16150, GBT16150-2025, GBT 16150, GBT16150