2026-6-16 216.73.217.103
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB/T 17217-2021
GB/T 17217-2021   Hygienic specification for public toilet (English)
Standard No.: GB/T 17217-2021 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 10500 words Translation Price(USD):315.0 remind me the price change

Email:

Implemented on:2021-10-1 Delivery: via email in 1 business day

→ → →

,,2021-10-1,8C1D2C9C22AF72A21616639540503
Standard No.: GB/T 17217-2021
English Name: Hygienic specification for public toilet
Chinese Name: 公共厕所卫生规范
Chinese Classification: C51    Environmental sanitation
Professional Classification: GB    National Standard
Source Content Issued by: SAMR; SAC
Issued on: 2021-03-09
Implemented on: 2021-10-1
Status: valid
Superseding:GB/T 17217-1998 Hygienic STANDARD for communal toilet in city
Target Language: English
File Format: PDF
Word Count: 10500 words
Translation Price(USD): 315.0
Delivery: via email in 1 business day
GB/T 17217-2021 Hygienic specification for public toilet 1 Scope This standard specifies the hygienic requirements for the planning, design, construction and management of public toilets, as well as the hygienic evaluation indicators and thresholds. This standard is applicable to the planning, design, construction, management and hygienic evaluation of new, renovated or expanded fixed public toilets for public use in cities, rural areas, tourist areas and expressway service areas, as well as public restrooms set up in public places. It may also serve as a reference for existing public toilets, public toilets in schools, and public toilets for internal staff of units. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB 7959 Hygienic requirements for harmless disposal of night soil GB/T 11742 Standard method for hygienic examination of hydrogen sulfide in air of residential areas - Methylene blue spectrophotometric method GB/T 14679 Air quality - Determination of ammonia - Sodium salicylate-sodium hypochlorite spectrophotometric method GB/T 18204.1 Examination methods for public places - Part 1: Physical parameters GB 18466 Discharge standard of water pollutants for medical organization GB 19379 Hygienic specification for rural household latrine GB/T 50337 Standard for planning of urban environment sanitation facilities CJJ 14 Standard for design of urban public toilets NY/T 1702-2009 Technology specifications of biogas digester for domestic sewage treatment 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 public toilet fixed toilets set up in public places for public use Note: Public toilets are classified into independence public toilets and dependence public toilets based on whether they are attached to other buildings. 3.2 innocuous sanitary toilet sanitary toilets equipped with facilities that can effectively reduce the infectivity of biological pathogenic factors in feces Note: Toilets with front treatment facilities, including septic tank type with three or more compartments, biogas tank type, double-urn or triple-urn type, urine diverting latrine, and water-flush type with complete water supply and drainage systems. 3.3 front treatment facilities treatment facility that ensures the faecal sludge from toilets meets the innocuous standards before being discharged 3.4 ratio of glazing area to floor area ratio of the effective light-transmitting area (Ac) of the window to the floor area (Ad) of the room, namely Ac/Ad 3.5 air exchange rate ratio of volume of air entering the room from outside (Ma, m³/h) to the indoor air volume of the room (M, m³) within 1h, namely Ma/M 4 Hygienic requirements for planning, design, and construction 4.1 Planning layout 4.1.1 Public toilets shall be comprehensively planned and rationally laid out in accordance with local conditions. 4.1.2 The distribution and quantity of urban public toilets shall meet the requirements of CJJ 14. 4.1.3 The distribution of public toilets in rural areas shall be arranged according to the service radius. The service radius of public toilets in residential areas should not exceed 150m, and the service radius of public toilets alternately arranged on both sides of streets should not exceed 250m. 4.1.4 Non-water-flush independence public toilets shall be at least 10m away from catering enterprises and kindergarten units, and at least 30m away from underground water intake structures of public toilets. 4.1.5 Open facilities such as domestic garbage pits and sewage pits that are conducive to the breeding of rats and flies shall not be set up around independence public toilets. 4.1.6 The existing resources of the dependence public toilets should be fully utilized. The design and construction of dependence public toilets should meet the all-day service condition to the public. 4.2 Design 4.2.1 General requirements 4.2.1.1 The design of toilets shall meet the basic requirements of hygiene, safety, privacy and convenience. 4.2.1.2 The auxiliary facilities should be added in accordance with local conditions such as the needs of the service population in the area where it is located, the economic development status, and the surrounding environmental conditions of the venue. 4.2.2 Scale of public toilets 4.2.2.1 The scale of urban public toilets shall comply with GB/T 50337 and CJJ 14. 4.2.2.2 When the number of men and women in the public toilet service area is comparable, the ratio of male to female cubicles should be 1:2. 4.2.3 Types of public toilets
Foreword i 1 Scope 2 Normative references 3 Terms and definitions 4 Hygienic requirements for planning, design, and construction 5 Hygienic evaluation indicators and thresholds 6 Management requirements Annex A (Normative) Hygienic requirements for the construction and operation management of three-compartment septic tank Annex B (Normative) Hygienic requirements for the construction and operation management of biogas digester Annex C (Normative) Hygienic requirements for the construction and operation management of urine diverting latrine Annex D (Normative) Hygienic requirements for the construction and operation management of double-urn and triple-urn storage tanks Annex E (Normative) Fly density detection method Annex F (Normative) Grade 4 odor intensity inspection method Annex G (Normative) Rapid instrumental detection method for fecal coliforms Bibliography
Code of China
Standard
GB/T 17217-2021  Hygienic specification for public toilet (English Version)
Standard No.GB/T 17217-2021
Statusvalid
LanguageEnglish
File FormatPDF
Word Count10500 words
Price(USD)315.0
Implemented on2021-10-1
Deliveryvia email in 1 business day
Detail of GB/T 17217-2021
Standard No.
GB/T 17217-2021
English Name
Hygienic specification for public toilet
Chinese Name
公共厕所卫生规范
Chinese Classification
C51
Professional Classification
GB
ICS Classification
Issued by
SAMR; SAC
Issued on
2021-03-09
Implemented on
2021-10-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
GB/T 17217-1998 Hygienic STANDARD for communal toilet in city
Language
English
File Format
PDF
Word Count
10500 words
Price(USD)
315.0
Keywords
GB/T 17217-2021, GB 17217-2021, GBT 17217-2021, GB/T17217-2021, GB/T 17217, GB/T17217, GB17217-2021, GB 17217, GB17217, GBT17217-2021, GBT 17217, GBT17217
Introduction of GB/T 17217-2021
GB/T 17217-2021 Hygienic specification for public toilet 1 Scope This standard specifies the hygienic requirements for the planning, design, construction and management of public toilets, as well as the hygienic evaluation indicators and thresholds. This standard is applicable to the planning, design, construction, management and hygienic evaluation of new, renovated or expanded fixed public toilets for public use in cities, rural areas, tourist areas and expressway service areas, as well as public restrooms set up in public places. It may also serve as a reference for existing public toilets, public toilets in schools, and public toilets for internal staff of units. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB 7959 Hygienic requirements for harmless disposal of night soil GB/T 11742 Standard method for hygienic examination of hydrogen sulfide in air of residential areas - Methylene blue spectrophotometric method GB/T 14679 Air quality - Determination of ammonia - Sodium salicylate-sodium hypochlorite spectrophotometric method GB/T 18204.1 Examination methods for public places - Part 1: Physical parameters GB 18466 Discharge standard of water pollutants for medical organization GB 19379 Hygienic specification for rural household latrine GB/T 50337 Standard for planning of urban environment sanitation facilities CJJ 14 Standard for design of urban public toilets NY/T 1702-2009 Technology specifications of biogas digester for domestic sewage treatment 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 public toilet fixed toilets set up in public places for public use Note: Public toilets are classified into independence public toilets and dependence public toilets based on whether they are attached to other buildings. 3.2 innocuous sanitary toilet sanitary toilets equipped with facilities that can effectively reduce the infectivity of biological pathogenic factors in feces Note: Toilets with front treatment facilities, including septic tank type with three or more compartments, biogas tank type, double-urn or triple-urn type, urine diverting latrine, and water-flush type with complete water supply and drainage systems. 3.3 front treatment facilities treatment facility that ensures the faecal sludge from toilets meets the innocuous standards before being discharged 3.4 ratio of glazing area to floor area ratio of the effective light-transmitting area (Ac) of the window to the floor area (Ad) of the room, namely Ac/Ad 3.5 air exchange rate ratio of volume of air entering the room from outside (Ma, m³/h) to the indoor air volume of the room (M, m³) within 1h, namely Ma/M 4 Hygienic requirements for planning, design, and construction 4.1 Planning layout 4.1.1 Public toilets shall be comprehensively planned and rationally laid out in accordance with local conditions. 4.1.2 The distribution and quantity of urban public toilets shall meet the requirements of CJJ 14. 4.1.3 The distribution of public toilets in rural areas shall be arranged according to the service radius. The service radius of public toilets in residential areas should not exceed 150m, and the service radius of public toilets alternately arranged on both sides of streets should not exceed 250m. 4.1.4 Non-water-flush independence public toilets shall be at least 10m away from catering enterprises and kindergarten units, and at least 30m away from underground water intake structures of public toilets. 4.1.5 Open facilities such as domestic garbage pits and sewage pits that are conducive to the breeding of rats and flies shall not be set up around independence public toilets. 4.1.6 The existing resources of the dependence public toilets should be fully utilized. The design and construction of dependence public toilets should meet the all-day service condition to the public. 4.2 Design 4.2.1 General requirements 4.2.1.1 The design of toilets shall meet the basic requirements of hygiene, safety, privacy and convenience. 4.2.1.2 The auxiliary facilities should be added in accordance with local conditions such as the needs of the service population in the area where it is located, the economic development status, and the surrounding environmental conditions of the venue. 4.2.2 Scale of public toilets 4.2.2.1 The scale of urban public toilets shall comply with GB/T 50337 and CJJ 14. 4.2.2.2 When the number of men and women in the public toilet service area is comparable, the ratio of male to female cubicles should be 1:2. 4.2.3 Types of public toilets
Contents of GB/T 17217-2021
Foreword i 1 Scope 2 Normative references 3 Terms and definitions 4 Hygienic requirements for planning, design, and construction 5 Hygienic evaluation indicators and thresholds 6 Management requirements Annex A (Normative) Hygienic requirements for the construction and operation management of three-compartment septic tank Annex B (Normative) Hygienic requirements for the construction and operation management of biogas digester Annex C (Normative) Hygienic requirements for the construction and operation management of urine diverting latrine Annex D (Normative) Hygienic requirements for the construction and operation management of double-urn and triple-urn storage tanks Annex E (Normative) Fly density detection method Annex F (Normative) Grade 4 odor intensity inspection method Annex G (Normative) Rapid instrumental detection method for fecal coliforms Bibliography
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 3680948734
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 17217-2021, GB 17217-2021, GBT 17217-2021, GB/T17217-2021, GB/T 17217, GB/T17217, GB17217-2021, GB 17217, GB17217, GBT17217-2021, GBT 17217, GBT17217