2026-4-4 216.73.216.113
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB/T 18280.2-2025
GB/T 18280.2-2025   Sterilization of health care products—Radiation—Part 2: Establishing the sterilization dose (English Version)
Standard No.: GB/T 18280.2-2025 Status:to be valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 28500 words Translation Price(USD):855.0 remind me the price change

Email:

Implemented on:2027-7-1 Delivery: via email in 1 business day

→ → →

,,2027-7-1,DE0979EBC44E5C191764841749820
Standard No.: GB/T 18280.2-2025
English Name: Sterilization of health care products—Radiation—Part 2: Establishing the sterilization dose
Chinese Name: 医疗产品灭菌 辐射 第2部分:建立灭菌剂量
Professional Classification: GB    National Standard
Source Content Issued by: SAMR;SAC
Issued on: 2025-12-2
Implemented on: 2027-7-1
Status: to be valid
Superseding:GB 18280.2-2015 Sterilization of health care products―Radiation―Part 2:Establishing the sterilization dose
Target Language: English
File Format: PDF
Word Count: 28500 words
Translation Price(USD): 855.0
Delivery: via email in 1 business day
GB/T 18280.2-2025 Sterilization of health care products - Radiation - Part 2: Establishing the sterilization dose 1 Scope This document specifies methods for determining the minimum dose needed to achieve a specified requirement for sterility and methods to substantiate the use of 15kGy, 17.5kGy, 20kGy, 22.5kGy, 25kGy, 27.5kGy, 30kGy, 32.5kGy or 35kGy as the sterilization dose to achieve a sterility assurance level (SAL) of 10-6, as well as methods of sterilization dose audit used to demonstrate the continued effectiveness of the sterilization dose. This document defines product families for sterilization dose establishment and sterilization dose audit. This document is applicable to the establishment and maintenance of radiation sterilization dose for medical devices. Note: This document is applicable to medical devices, but the establishment and maintenance of radiation sterilization dose may be applicable to other products. 2 Normative references The following documents contain provisions which, through reference in this text, constitute provisions of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB 18280.1 Sterilization of health care products - Radiation - Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices (GB 18280.1-2025, ISO 11137-1: 2025, MOD) GB/T 19973.1 Sterilization of health care products - Microbiological methods - Part 1: Determination of a population of microorganisms on products (GB/T 19973.1-2023, ISO 11737-1: 2018, IDT) GB/T 19973.2 Sterilization of health care products - Microbiological methods - Part 2: Tests of sterility performed in the definition, validation and maintenance of a sterilization process (GB/T 19973.2-2025, ISO 11737-2: 2019, IDT) ISO 13004 Sterilization of health care products - Radiation - Substantiation of selected sterilization dose: Method VDmaxSD 3 Terms, definitions and abbreviated terms 3.1 Terms and definitions For the purposes of this document, the terms and definitions given in GB 18280.1 and the following apply. 3.1.1 batch defined quantity of a product intended or purported to be uniform in character and quality, which has been produced during a defined cycle of manufacture [Source: GB/T 19973.1-2023, 3.1] 3.1.2 bioburden population of viable microorganisms on or in product and/or sterile barrier system [Source: GB/T 19633.1-2024, 3.2] 3.1.3 false positive test result interpreted as growth arising from the product, or portions thereof, tested when either growth resulted from extraneous microbial contamination or turbidity occurred from interaction between the product, or portions thereof, and the test medium 3.1.4 fraction positive quotient in which the number of positive tests of sterility is given by the numerator and the number of tests performed is given by the denominator [Source: ISO 11139: 2018, 3.122] 3.1.5 incremental dose dose within a series of doses applied to a number of products, or portions thereof, and used in a dose setting method to obtain or confirm the sterilization dose [Source: ISO 11139: 2018, 3.138] 3.1.6 negative test of sterility test result for which there is no detectable microbial growth from product, or portions thereof, subjected to a test of sterility 3.1.7 packaging system combination of the sterile barrier system and protective packaging [Source: GB/T 19633.2-2024, 3.11] 3.1.8 positive test of sterility test result for which there is detectable microbial growth from product, or portions thereof, subjected to a test of sterility 3.1.9 sample item portion; SIP defined portion of a health care product that is tested [Source: GB/T 19973.2-2025, 3.10] 3.1.10 standard distribution of resistances; SDR reference set of resistances of microorganisms and corresponding probabilities of occurrence [Source: ISO 11139: 2018, 3.263] 3.1.11 sterile barrier system minimum package that minimizes the risk of ingress of microorganisms and allows aseptic presentation of the product at the point of use [Source: GB/T 19633.2-2024, 3.25] 3.1.12 sterility assurance level; SAL probability of a single viable microorganism occurring on a product after sterilization Note 1: It is expressed as the negative exponent to the base 10. Note 2: The term SAL takes a quantitative value, generally 10-6 or 10-3. When applying this quantitative value to assurance of sterility, an SAL of 10-6 has a lower value but provides a greater assurance of sterility than an SAL of 10-3. [Source: ISO 11139: 2018, 3.275, modified, Note 2 added] 3.1.13 sterilization dose audit exercise undertaken to confirm the appropriateness of an established sterilization dose [Source: ISO 11139: 2018, 3.281] 3.1.14 test of sterility technical operation performed as part of development, validation, or requalification to determine the presence or absence of viable microorganisms on product or portions thereof
Foreword i Introduction iv 1 Scope 2 Normative references 3 Terms, definitions and abbreviated terms 4 Definition and maintenance of product families for dose setting, dose substantiation, and sterilization dose audit 5 Selection and test of product for establishing the sterilization dose 6 Methods of dose establishment 7 Method 1: dose setting using bioburden information 8 Method 2: Dose setting using fraction positive information from incremental dose experiment to determine an extrapolation factor 9 Method VDmax——Substantiation of the selected sterilization dose 10 Sterilization dose audit 11 Worked examples Bibliography
Code of China
Standard
GB/T 18280.2-2025  Sterilization of health care products—Radiation—Part 2: Establishing the sterilization dose (English Version)
Standard No.GB/T 18280.2-2025
Statusto be valid
LanguageEnglish
File FormatPDF
Word Count28500 words
Price(USD)855.0
Implemented on2027-7-1
Deliveryvia email in 1 business day
Detail of GB/T 18280.2-2025
Standard No.
GB/T 18280.2-2025
English Name
Sterilization of health care products—Radiation—Part 2: Establishing the sterilization dose
Chinese Name
医疗产品灭菌 辐射 第2部分:建立灭菌剂量
Chinese Classification
Professional Classification
GB
ICS Classification
Issued by
SAMR;SAC
Issued on
2025-12-2
Implemented on
2027-7-1
Status
to be valid
Superseded by
Superseded on
Abolished on
Superseding
GB 18280.2-2015 Sterilization of health care products―Radiation―Part 2:Establishing the sterilization dose
Language
English
File Format
PDF
Word Count
28500 words
Price(USD)
855.0
Keywords
GB/T 18280.2-2025, GB 18280.2-2025, GBT 18280.2-2025, GB/T18280.2-2025, GB/T 18280.2, GB/T18280.2, GB18280.2-2025, GB 18280.2, GB18280.2, GBT18280.2-2025, GBT 18280.2, GBT18280.2
Introduction of GB/T 18280.2-2025
GB/T 18280.2-2025 Sterilization of health care products - Radiation - Part 2: Establishing the sterilization dose 1 Scope This document specifies methods for determining the minimum dose needed to achieve a specified requirement for sterility and methods to substantiate the use of 15kGy, 17.5kGy, 20kGy, 22.5kGy, 25kGy, 27.5kGy, 30kGy, 32.5kGy or 35kGy as the sterilization dose to achieve a sterility assurance level (SAL) of 10-6, as well as methods of sterilization dose audit used to demonstrate the continued effectiveness of the sterilization dose. This document defines product families for sterilization dose establishment and sterilization dose audit. This document is applicable to the establishment and maintenance of radiation sterilization dose for medical devices. Note: This document is applicable to medical devices, but the establishment and maintenance of radiation sterilization dose may be applicable to other products. 2 Normative references The following documents contain provisions which, through reference in this text, constitute provisions of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB 18280.1 Sterilization of health care products - Radiation - Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices (GB 18280.1-2025, ISO 11137-1: 2025, MOD) GB/T 19973.1 Sterilization of health care products - Microbiological methods - Part 1: Determination of a population of microorganisms on products (GB/T 19973.1-2023, ISO 11737-1: 2018, IDT) GB/T 19973.2 Sterilization of health care products - Microbiological methods - Part 2: Tests of sterility performed in the definition, validation and maintenance of a sterilization process (GB/T 19973.2-2025, ISO 11737-2: 2019, IDT) ISO 13004 Sterilization of health care products - Radiation - Substantiation of selected sterilization dose: Method VDmaxSD 3 Terms, definitions and abbreviated terms 3.1 Terms and definitions For the purposes of this document, the terms and definitions given in GB 18280.1 and the following apply. 3.1.1 batch defined quantity of a product intended or purported to be uniform in character and quality, which has been produced during a defined cycle of manufacture [Source: GB/T 19973.1-2023, 3.1] 3.1.2 bioburden population of viable microorganisms on or in product and/or sterile barrier system [Source: GB/T 19633.1-2024, 3.2] 3.1.3 false positive test result interpreted as growth arising from the product, or portions thereof, tested when either growth resulted from extraneous microbial contamination or turbidity occurred from interaction between the product, or portions thereof, and the test medium 3.1.4 fraction positive quotient in which the number of positive tests of sterility is given by the numerator and the number of tests performed is given by the denominator [Source: ISO 11139: 2018, 3.122] 3.1.5 incremental dose dose within a series of doses applied to a number of products, or portions thereof, and used in a dose setting method to obtain or confirm the sterilization dose [Source: ISO 11139: 2018, 3.138] 3.1.6 negative test of sterility test result for which there is no detectable microbial growth from product, or portions thereof, subjected to a test of sterility 3.1.7 packaging system combination of the sterile barrier system and protective packaging [Source: GB/T 19633.2-2024, 3.11] 3.1.8 positive test of sterility test result for which there is detectable microbial growth from product, or portions thereof, subjected to a test of sterility 3.1.9 sample item portion; SIP defined portion of a health care product that is tested [Source: GB/T 19973.2-2025, 3.10] 3.1.10 standard distribution of resistances; SDR reference set of resistances of microorganisms and corresponding probabilities of occurrence [Source: ISO 11139: 2018, 3.263] 3.1.11 sterile barrier system minimum package that minimizes the risk of ingress of microorganisms and allows aseptic presentation of the product at the point of use [Source: GB/T 19633.2-2024, 3.25] 3.1.12 sterility assurance level; SAL probability of a single viable microorganism occurring on a product after sterilization Note 1: It is expressed as the negative exponent to the base 10. Note 2: The term SAL takes a quantitative value, generally 10-6 or 10-3. When applying this quantitative value to assurance of sterility, an SAL of 10-6 has a lower value but provides a greater assurance of sterility than an SAL of 10-3. [Source: ISO 11139: 2018, 3.275, modified, Note 2 added] 3.1.13 sterilization dose audit exercise undertaken to confirm the appropriateness of an established sterilization dose [Source: ISO 11139: 2018, 3.281] 3.1.14 test of sterility technical operation performed as part of development, validation, or requalification to determine the presence or absence of viable microorganisms on product or portions thereof
Contents of GB/T 18280.2-2025
Foreword i Introduction iv 1 Scope 2 Normative references 3 Terms, definitions and abbreviated terms 4 Definition and maintenance of product families for dose setting, dose substantiation, and sterilization dose audit 5 Selection and test of product for establishing the sterilization dose 6 Methods of dose establishment 7 Method 1: dose setting using bioburden information 8 Method 2: Dose setting using fraction positive information from incremental dose experiment to determine an extrapolation factor 9 Method VDmax——Substantiation of the selected sterilization dose 10 Sterilization dose audit 11 Worked examples Bibliography
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Contact us via WeChat
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 3680948734
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 18280.2-2025, GB 18280.2-2025, GBT 18280.2-2025, GB/T18280.2-2025, GB/T 18280.2, GB/T18280.2, GB18280.2-2025, GB 18280.2, GB18280.2, GBT18280.2-2025, GBT 18280.2, GBT18280.2