2026-6-6 216.73.216.133
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB/T 21091-2026
GB/T 21091-2026   Self-ballasted electrodeless fluorescent lamps for general lighting services—Performance specifications (English)
Standard No.: GB/T 21091-2026 Status:to be valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 9000 words Translation Price(USD):270.0 remind me the price change

Email:

Implemented on:2026-11-1 Delivery: via email in 1~3 business day

→ → →

,,2026-11-1,C5035543381C97861778135006096
Standard No.: GB/T 21091-2026
English Name: Self-ballasted electrodeless fluorescent lamps for general lighting services—Performance specifications
Chinese Name: 普通照明用自镇流无极荧光灯 性能规范
Professional Classification: GB    National Standard
Source Content Issued by: SAMR, SAC
Issued on: 2026-04-30
Implemented on: 2026-11-1
Status: to be valid
Superseding:GB/T 21091-2007 Self-ballasted electrodeless fluorescent lamps for general lighting services - Performance requirements
Target Language: English
File Format: PDF
Word Count: 9000 words
Translation Price(USD): 270.0
Delivery: via email in 1~3 business day
GB/T 21091-2026 Self-ballasted electrodeless fluorescent lamps for general lighting services—Performance specifications English, Anglais, Englisch, Inglés, えいご This is a draft translation for reference among interesting stakeholders. The finalized translation (passing through draft translation, self-check, revision and verification) will be delivered upon being ordered. ICS CCS National Standard of the People's Republic of China ‌GB/T 21091-2026 Self-ballasted electrodeless fluorescent lamps for general lighting services - Performance specifications 普通照明用自镇流无极荧光灯 性能规范 Issue date: 2026-04-30 Implementation date: 2026-10-01 Issued by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China the Standardization Administration of the People's Republic of China Contents Foreword 1 Scope 2 Normative References 3 Terms and Definitions 4 Classification and Type Designation 5 Requirements 6 Test Methods 7 Inspection Rules 8 Marking, Packaging, Transport and Storage Selfballasted electrodeless fluorescent lamps for general lighting services — Performance specification 1 Scope This document specifies the product classification, requirements, inspection rules, marking, packaging, transport and storage for selfballasted electrodeless fluorescent lamps (hereinafter referred to as “lamps”), and describes the corresponding test methods. This document applies to lamps with a rated voltage of 220 V and frequency of 50 Hz, using Edison screw or bayonet caps, intended for general lighting service in domestic and similar applications. 2 Normative References The following documents are essential for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition (including any amendments) applies. GB/T 1406.1 Types and dimensions of lamp caps — Part 1: Edison screw caps GB/T 1406.5 Types and dimensions of lamp caps — Part 5: Bayonet caps GB/T 1483.1 Gauges for lamp caps and lampholders — Part 1: Gauges for Edison screw caps and lampholders GB/T 1483.5 Gauges for lamp caps and lampholders — Part 5: Gauges for bayonet caps and lampholders GB/T 2828.1 Sampling procedures for inspection by attributes — Part 1: Sampling schemes indexed by acceptance quality limit (AQL) for lotbylot inspection GB/T 2829 Sampling procedures and tables for periodic inspection by attributes (applicable to inspection of process stability) GB/T 2900.65 Electrotechnical terminology — Lighting GB/T 17262-2011 Singlecapped fluorescent lamps — Performance specification GB/T 17263-2025 Selfballasted fluorescent lamps for general lighting services — Performance specification GB 17625.1 Electromagnetic compatibility — Limits — Part 1: Limits for harmonic current emissions (equipment input current ≤ 16 A per phase) GB/T 17743 Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment GB/T 18595 Electromagnetic compatibility — Immunity requirements for general lighting equipment GB 21554 Selfballasted electrodeless fluorescent lamps for general lighting services — Safety requirements 3 Terms and Definitions For the purposes of this document, the terms and definitions given in GB/T 2900.65 and the following apply. 3.1 electrodeless fluorescent lamp A fluorescent lamp without electrodes, in which discharge energy is provided to the lowpressure mercury vapour by electromagnetic coupling. 3.2 selfballasted electrodeless fluorescent lamp An electrodeless fluorescent lamp incorporating a lamp cap, ballast, discharge tube and coupling elements as an integral unit, which is not intended to be disassembled without damage to the lamp. 3.3 rated value (light sources and related equipment) A value used for specification purposes, declared by the producer or supplier and determined under standard test conditions. NOTE 1: To indicate the “rated value” of a specific quantity, the term “value” is replaced by the name of the quantity, e.g., rated power, rated voltage, rated current and rated temperature. NOTE 2: Standard test conditions are given in relevant standards. [Source: GB/T 2900.65-2023, 845-27-100] 3.4 initial values Values of starting characteristics, electrical characteristics, photometric characteristics and colour characteristics measured after the lamp has been seasoned for 100 h. 3.5 power factor The ratio of the active power of the lamp to the product of the supply voltage (r.m.s. value) and the supply current (r.m.s. value). 3.6 lumen maintenance The ratio, expressed as a percentage, of the luminous flux of the lamp at a given time during its life to its initial luminous flux, when the lamp is operated under specified conditions. 3.7 luminous efficacy The ratio of the luminous flux emitted by a light source to the power consumed by it. 3.8 life The total operating time of a lamp up to the point when it is no longer usable or when it is considered to have failed according to specified criteria. NOTE 1: The unit of lamp life is usually the hour (h). NOTE 2: This term is numbered 845-07-61 in IEC 60050845:1987. [Source: GB/T 2900.65-2023, 845-27-101] 3.9 median life In a life test of n lamps (n ≥ 10), the life at which 50 % of the lamps have failed, in order of failure. 3.10 starting time The time required for the lamp to start fully and maintain stable operation after the supply voltage is switched on. 3.11 runup time The time required for the luminous flux of the lamp to reach 80 % of its stabilised luminous flux after the supply voltage is switched on. 3.12 stabilisation time The time required for the photometric and electrical characteristics of the lamp to stabilise after the supply voltage is switched on. 4 Classification and Type Designation 4.1 Product classification Lamps are classified according to the discharge tube configuration into: twintube, quadrupletube, multitube, as well as spiral, circular, spherical, reflector, etc. The types shall comply with the requirements of Annex E of GB/T 17262-2011. 4.2 Type designation rules The type designation rules for lamps are as follows. Example: The type designation for a selfballasted electrodeless lamp for general lighting services with 220 V, 50 Hz, 40 W, daylight colour is WJZ 220 V 50 Hz 40 WRR. NOTE: The lamp operating current, lamp construction type and other lamp information are optional marking items. 5 Requirements 5.1 Safety requirements The safety requirements for lamps shall comply with the provisions of GB 21554. 5.2 Lamp dimensions The dimensions of the lamp shall comply with the manufacturer‘s declared specifications. The lamp cap used shall comply with the requirements of GB/T 1406.1 or GB/T 1406.5. 5.3 Starting performance 5.3.1 Starting time The starting time of the lamp shall comply with the following requirements: a) Starting at ambient temperature At an ambient temperature of 25 °C ± 1 °C and 92 % of the rated voltage, the starting time shall not exceed 1 s. b) Starting at low temperature At a temperature of –10 °C and 92 % of the rated voltage, the starting time shall not exceed 10 s. For lamps for which the manufacturer declares a lower starting temperature or a shorter starting time, they shall start within the declared minimum temperature and starting time at 92 % of the rated voltage. 5.3.2 Runup time The runup time of the lamp shall not exceed 3 s.
Code of China
Standard
GB/T 21091-2026  Self-ballasted electrodeless fluorescent lamps for general lighting services—Performance specifications (English Version)
Standard No.GB/T 21091-2026
Statusto be valid
LanguageEnglish
File FormatPDF
Word Count9000 words
Price(USD)270.0
Implemented on2026-11-1
Deliveryvia email in 1~3 business day
Detail of GB/T 21091-2026
Standard No.
GB/T 21091-2026
English Name
Self-ballasted electrodeless fluorescent lamps for general lighting services—Performance specifications
Chinese Name
普通照明用自镇流无极荧光灯 性能规范
Chinese Classification
Professional Classification
GB
ICS Classification
Issued by
SAMR, SAC
Issued on
2026-04-30
Implemented on
2026-11-1
Status
to be valid
Superseded by
Superseded on
Abolished on
Superseding
GB/T 21091-2007 Self-ballasted electrodeless fluorescent lamps for general lighting services - Performance requirements
Language
English
File Format
PDF
Word Count
9000 words
Price(USD)
270.0
Keywords
GB/T 21091-2026, GB 21091-2026, GBT 21091-2026, GB/T21091-2026, GB/T 21091, GB/T21091, GB21091-2026, GB 21091, GB21091, GBT21091-2026, GBT 21091, GBT21091
Introduction of GB/T 21091-2026
GB/T 21091-2026 Self-ballasted electrodeless fluorescent lamps for general lighting services—Performance specifications English, Anglais, Englisch, Inglés, えいご This is a draft translation for reference among interesting stakeholders. The finalized translation (passing through draft translation, self-check, revision and verification) will be delivered upon being ordered. ICS CCS National Standard of the People's Republic of China ‌GB/T 21091-2026 Self-ballasted electrodeless fluorescent lamps for general lighting services - Performance specifications 普通照明用自镇流无极荧光灯 性能规范 Issue date: 2026-04-30 Implementation date: 2026-10-01 Issued by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China the Standardization Administration of the People's Republic of China Contents Foreword 1 Scope 2 Normative References 3 Terms and Definitions 4 Classification and Type Designation 5 Requirements 6 Test Methods 7 Inspection Rules 8 Marking, Packaging, Transport and Storage Selfballasted electrodeless fluorescent lamps for general lighting services — Performance specification 1 Scope This document specifies the product classification, requirements, inspection rules, marking, packaging, transport and storage for selfballasted electrodeless fluorescent lamps (hereinafter referred to as “lamps”), and describes the corresponding test methods. This document applies to lamps with a rated voltage of 220 V and frequency of 50 Hz, using Edison screw or bayonet caps, intended for general lighting service in domestic and similar applications. 2 Normative References The following documents are essential for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition (including any amendments) applies. GB/T 1406.1 Types and dimensions of lamp caps — Part 1: Edison screw caps GB/T 1406.5 Types and dimensions of lamp caps — Part 5: Bayonet caps GB/T 1483.1 Gauges for lamp caps and lampholders — Part 1: Gauges for Edison screw caps and lampholders GB/T 1483.5 Gauges for lamp caps and lampholders — Part 5: Gauges for bayonet caps and lampholders GB/T 2828.1 Sampling procedures for inspection by attributes — Part 1: Sampling schemes indexed by acceptance quality limit (AQL) for lotbylot inspection GB/T 2829 Sampling procedures and tables for periodic inspection by attributes (applicable to inspection of process stability) GB/T 2900.65 Electrotechnical terminology — Lighting GB/T 17262-2011 Singlecapped fluorescent lamps — Performance specification GB/T 17263-2025 Selfballasted fluorescent lamps for general lighting services — Performance specification GB 17625.1 Electromagnetic compatibility — Limits — Part 1: Limits for harmonic current emissions (equipment input current ≤ 16 A per phase) GB/T 17743 Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment GB/T 18595 Electromagnetic compatibility — Immunity requirements for general lighting equipment GB 21554 Selfballasted electrodeless fluorescent lamps for general lighting services — Safety requirements 3 Terms and Definitions For the purposes of this document, the terms and definitions given in GB/T 2900.65 and the following apply. 3.1 electrodeless fluorescent lamp A fluorescent lamp without electrodes, in which discharge energy is provided to the lowpressure mercury vapour by electromagnetic coupling. 3.2 selfballasted electrodeless fluorescent lamp An electrodeless fluorescent lamp incorporating a lamp cap, ballast, discharge tube and coupling elements as an integral unit, which is not intended to be disassembled without damage to the lamp. 3.3 rated value (light sources and related equipment) A value used for specification purposes, declared by the producer or supplier and determined under standard test conditions. NOTE 1: To indicate the “rated value” of a specific quantity, the term “value” is replaced by the name of the quantity, e.g., rated power, rated voltage, rated current and rated temperature. NOTE 2: Standard test conditions are given in relevant standards. [Source: GB/T 2900.65-2023, 845-27-100] 3.4 initial values Values of starting characteristics, electrical characteristics, photometric characteristics and colour characteristics measured after the lamp has been seasoned for 100 h. 3.5 power factor The ratio of the active power of the lamp to the product of the supply voltage (r.m.s. value) and the supply current (r.m.s. value). 3.6 lumen maintenance The ratio, expressed as a percentage, of the luminous flux of the lamp at a given time during its life to its initial luminous flux, when the lamp is operated under specified conditions. 3.7 luminous efficacy The ratio of the luminous flux emitted by a light source to the power consumed by it. 3.8 life The total operating time of a lamp up to the point when it is no longer usable or when it is considered to have failed according to specified criteria. NOTE 1: The unit of lamp life is usually the hour (h). NOTE 2: This term is numbered 845-07-61 in IEC 60050845:1987. [Source: GB/T 2900.65-2023, 845-27-101] 3.9 median life In a life test of n lamps (n ≥ 10), the life at which 50 % of the lamps have failed, in order of failure. 3.10 starting time The time required for the lamp to start fully and maintain stable operation after the supply voltage is switched on. 3.11 runup time The time required for the luminous flux of the lamp to reach 80 % of its stabilised luminous flux after the supply voltage is switched on. 3.12 stabilisation time The time required for the photometric and electrical characteristics of the lamp to stabilise after the supply voltage is switched on. 4 Classification and Type Designation 4.1 Product classification Lamps are classified according to the discharge tube configuration into: twintube, quadrupletube, multitube, as well as spiral, circular, spherical, reflector, etc. The types shall comply with the requirements of Annex E of GB/T 17262-2011. 4.2 Type designation rules The type designation rules for lamps are as follows. Example: The type designation for a selfballasted electrodeless lamp for general lighting services with 220 V, 50 Hz, 40 W, daylight colour is WJZ 220 V 50 Hz 40 WRR. NOTE: The lamp operating current, lamp construction type and other lamp information are optional marking items. 5 Requirements 5.1 Safety requirements The safety requirements for lamps shall comply with the provisions of GB 21554. 5.2 Lamp dimensions The dimensions of the lamp shall comply with the manufacturer‘s declared specifications. The lamp cap used shall comply with the requirements of GB/T 1406.1 or GB/T 1406.5. 5.3 Starting performance 5.3.1 Starting time The starting time of the lamp shall comply with the following requirements: a) Starting at ambient temperature At an ambient temperature of 25 °C ± 1 °C and 92 % of the rated voltage, the starting time shall not exceed 1 s. b) Starting at low temperature At a temperature of –10 °C and 92 % of the rated voltage, the starting time shall not exceed 10 s. For lamps for which the manufacturer declares a lower starting temperature or a shorter starting time, they shall start within the declared minimum temperature and starting time at 92 % of the rated voltage. 5.3.2 Runup time The runup time of the lamp shall not exceed 3 s.
Contents of GB/T 21091-2026
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 3680948734
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 21091-2026, GB 21091-2026, GBT 21091-2026, GB/T21091-2026, GB/T 21091, GB/T21091, GB21091-2026, GB 21091, GB21091, GBT21091-2026, GBT 21091, GBT21091