GB/T 25446-2026 Technical parameters and requirements for oil-immersed amorphous alloy core power transformers English, Anglais, Englisch, Inglés, えいご
This is a draft translation for reference among interesting stakeholders. The finalized translation (passing through draft translation, self-check, revision and verification) will be delivered upon being ordered.
ICS
CCS
National Standard of the People's Republic of China
GB/T 25446-2026
Technical parameters and requirements for oil-immersed amorphous alloy core power transformers
油浸式非晶合金铁芯电力变压器技术参数和要求
Issue date: 2026-09-28 Implementation date: 2027-01-01
Issued by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
the Standardization Administration of the People's Republic of China
Contents
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Performance parameters
5 Technical requirements
6 Inspection rules and methods
7 Marking, lifting, packaging, transportation and storage
Annex A (informative) Efficiency calculation and energy efficiency assessment
Bibliography
Figure A.1 — Efficiency curve plotted according to the calculation results of the loss values listed in Table A.1 according to Formula (A.2)
Table 1 — 6 kV, 10 kV class 5 kVA~160 kVA single-phase non-excitation tap-changing amorphous alloy core distribution transformers
Table 2 — 6 kV, 10 kV class 30 kVA~4 000 kVA three-phase non-excitation tap-changing amorphous alloy core distribution transformers
Table 3 — 20 kV class 30 kVA~4 000 kVA three-phase non-excitation tap-changing amorphous alloy core distribution transformers
Table 4 — 35 kV class 50 kVA~2 500 kVA three-phase non-excitation tap-changing amorphous alloy core distribution transformers
Table 5 — 6 kV, 10 kV class 630 kVA~6 300 kVA three-phase non-excitation tap-changing amorphous alloy core power transformers
Table 6 — 35 kV class 630 kVA~12 500 kVA three-phase non-excitation tap-changing amorphous alloy core power transformers
Table 7 — Sound level
Table A.1 — Comparison of parameter values for 10 kV class, 3 150 kVA oil-immersed power transformers
Oil-immersed amorphous alloy core power transformers — Technical parameters and requirements
1 Scope
This document specifies the performance parameters, technical requirements, marking, lifting, packaging, transportation and storage requirements for oil-immersed amorphous alloy core power transformers, and describes the corresponding inspection rules and methods.
This document is applicable to the manufacture of single-phase and three-phase oil-immersed amorphous alloy core power transformers (hereinafter referred to as "transformers") with a rated frequency of 50 Hz and voltage levels of 6 kV, 10 kV, 20 kV and 35 kV.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition (including any amendments) applies.
GB/T 1094.1, Power transformers — Part 1: General
GB/T 1094.2, Power transformers — Part 2: Temperature rise for liquid-immersed transformers
GB/T 1094.3, Power transformers — Part 3: Insulation levels, dielectric tests and external clearances in air
GB/T 1094.5, Power transformers — Part 5: Ability to withstand short circuit
GB/T 1094.7, Power transformers — Part 7: Loading guide for oil-immersed power transformers
GB/T 1094.10, Power transformers — Part 10: Determination of sound levels
GB/T 1094.20—2026, Power transformers — Part 20: Energy efficiency
GB/T 2900.95, Electrotechnical terminology — Transformers, voltage regulators and reactors
GB/T 6451—2023, Technical parameters and requirements for oil-immersed power transformers
JB/T 501, Guide for testing power transformers
3 Terms and definitions
For the purposes of this document, the terms and definitions given in GB/T 1094.1, GB/T 1094.20—2026 and GB/T 2900.95, as well as the following, apply.
3.1
amorphous alloy
An alloy with elements such as iron, silicon and boron as raw materials, whose internal atoms are arranged in a disordered manner by special processes such as rapid cooling.
3.2
amorphous alloy core
A core made of amorphous alloy strip with soft magnetic properties.
3.3
oil-immersed amorphous alloy core power transformer
An oil-immersed power transformer with an amorphous alloy core as the magnetic circuit.
4 Performance parameters
Tables 1 to 6 specify the performance parameters of non-excitation tap-changing amorphous alloy core transformers of various voltage levels and corresponding capacities. They also calculate the peak efficiency (PEI) and the efficiency at 50 % load (EI50EI50) based on the efficiency calculation formula in GB/T 1094.20—2026, and list them in the tables.
The performance parameters of non-excitation tap-changing amorphous alloy core distribution transformers shall comply with the provisions of Tables 1 to 4.
The performance parameters of non-excitation tap-changing amorphous alloy core power transformers shall comply with the provisions of Tables 5 and 6.
If the voltage, tapping range, connection symbol or short-circuit impedance differs from the provisions in Tables 1 to 6, the relevant performance parameters shall be determined by agreement between the user and the manufacturer.
Note: For on-load tap-changing amorphous alloy core transformers, the performance parameters are generally reasonably determined by the user and the manufacturer with reference to the principles given in Annex A, based on the performance parameters of the same type of on-load tap-changing grain-oriented silicon steel core transformers and in combination with the comparison results of energy efficiency levels.
Table 1 — 6 kV, 10 kV class 5 kVA to 160 kVA single-phase non-excitation tap-changing amorphous alloy core distribution transformers
5 Technical requirements
5.1 General requirements
Transformers manufactured in accordance with this document shall comply with the provisions of GB/T 1094.1, GB/T 1094.2, GB/T 1094.3, GB/T 1094.5 and GB/T 1094.7.
In addition to complying with 5.2 and 5.3, transformers shall also comply with the provisions of 4.2, 5.2 and 6.2 in GB/T 6451—2023.
5.2 Sound level
The sound level of transformers [under oil-immersed self-cooling (ONAN) cooling mode] shall comply with the provisions of Table 7. The sound level measurement method shall be in accordance with the provisions of GB/T 1094.10.
Table 7 — Sound level
5.3 Stability of core performance
The transformer shall maintain the stability of core performance under normal operation, short circuit, and other impact forces. If necessary, relevant special test verifications may be carried out after negotiation between the user and the manufacturer; for example, transformer short-circuit withstand capability test, transformer transport bump test, etc.
6 Inspection rules and methods
6.1 General
The tests of transformers include routine tests, type tests and special tests. The test items, test requirements and test methods shall comply with the provisions of GB/T 1094.1 and JB/T 501.
In addition, the transformer shall also comply with the provisions of 6.2 and 6.3, and the provisions of 4.3.5.3 and 6.3 in GB/T 6451—2023.
6.2 Short-circuit withstand capability test
The short-circuit withstand capability test of the transformer shall be in accordance with the provisions of GB/T 1094.5.
The difference between the measured values of the no-load loss of the transformer before and after the short-circuit withstand capability test shall not exceed 12 %. The measurements shall be carried out in the same test room. At the same time, a lightning impulse test shall also be carried out during this phase.
6.3 Transport bump test
According to the agreement between the user and the manufacturer, the transformer may be subjected to a transport bump test. This test is a special test. The test methods and requirements shall be agreed upon by the user and the manufacturer.
7 Marking, lifting, packaging, transportation and storage
The marking, lifting, packaging, transportation and storage of transformers shall be in accordance with the provisions of 4.4, 5.4 and 6.4 in GB/T 6451—2023.
Standard
GB/T 25446-2026 Technical parameters and requirements for oil-immersed amorphous alloy core power transformers (English)
Standard No.
GB/T 25446-2026
Status
to be valid
Language
English
File Format
PDF
Word Count
10500 words
Translation Price(USD)
315.0
Implemented on
2027-4-1
Delivery
via email in 1~5 business day
Detail of GB/T 25446-2026
Standard No.
GB/T 25446-2026
English Name
Technical parameters and requirements for oil-immersed amorphous alloy core power transformers
GB/T 25446-2026 Technical parameters and requirements for oil-immersed amorphous alloy core power transformers English, Anglais, Englisch, Inglés, えいご
This is a draft translation for reference among interesting stakeholders. The finalized translation (passing through draft translation, self-check, revision and verification) will be delivered upon being ordered.
ICS
CCS
National Standard of the People's Republic of China
GB/T 25446-2026
Technical parameters and requirements for oil-immersed amorphous alloy core power transformers
油浸式非晶合金铁芯电力变压器技术参数和要求
Issue date: 2026-09-28 Implementation date: 2027-01-01
Issued by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
the Standardization Administration of the People's Republic of China
Contents
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Performance parameters
5 Technical requirements
6 Inspection rules and methods
7 Marking, lifting, packaging, transportation and storage
Annex A (informative) Efficiency calculation and energy efficiency assessment
Bibliography
Figure A.1 — Efficiency curve plotted according to the calculation results of the loss values listed in Table A.1 according to Formula (A.2)
Table 1 — 6 kV, 10 kV class 5 kVA~160 kVA single-phase non-excitation tap-changing amorphous alloy core distribution transformers
Table 2 — 6 kV, 10 kV class 30 kVA~4 000 kVA three-phase non-excitation tap-changing amorphous alloy core distribution transformers
Table 3 — 20 kV class 30 kVA~4 000 kVA three-phase non-excitation tap-changing amorphous alloy core distribution transformers
Table 4 — 35 kV class 50 kVA~2 500 kVA three-phase non-excitation tap-changing amorphous alloy core distribution transformers
Table 5 — 6 kV, 10 kV class 630 kVA~6 300 kVA three-phase non-excitation tap-changing amorphous alloy core power transformers
Table 6 — 35 kV class 630 kVA~12 500 kVA three-phase non-excitation tap-changing amorphous alloy core power transformers
Table 7 — Sound level
Table A.1 — Comparison of parameter values for 10 kV class, 3 150 kVA oil-immersed power transformers
Oil-immersed amorphous alloy core power transformers — Technical parameters and requirements
1 Scope
This document specifies the performance parameters, technical requirements, marking, lifting, packaging, transportation and storage requirements for oil-immersed amorphous alloy core power transformers, and describes the corresponding inspection rules and methods.
This document is applicable to the manufacture of single-phase and three-phase oil-immersed amorphous alloy core power transformers (hereinafter referred to as "transformers") with a rated frequency of 50 Hz and voltage levels of 6 kV, 10 kV, 20 kV and 35 kV.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition (including any amendments) applies.
GB/T 1094.1, Power transformers — Part 1: General
GB/T 1094.2, Power transformers — Part 2: Temperature rise for liquid-immersed transformers
GB/T 1094.3, Power transformers — Part 3: Insulation levels, dielectric tests and external clearances in air
GB/T 1094.5, Power transformers — Part 5: Ability to withstand short circuit
GB/T 1094.7, Power transformers — Part 7: Loading guide for oil-immersed power transformers
GB/T 1094.10, Power transformers — Part 10: Determination of sound levels
GB/T 1094.20—2026, Power transformers — Part 20: Energy efficiency
GB/T 2900.95, Electrotechnical terminology — Transformers, voltage regulators and reactors
GB/T 6451—2023, Technical parameters and requirements for oil-immersed power transformers
JB/T 501, Guide for testing power transformers
3 Terms and definitions
For the purposes of this document, the terms and definitions given in GB/T 1094.1, GB/T 1094.20—2026 and GB/T 2900.95, as well as the following, apply.
3.1
amorphous alloy
An alloy with elements such as iron, silicon and boron as raw materials, whose internal atoms are arranged in a disordered manner by special processes such as rapid cooling.
3.2
amorphous alloy core
A core made of amorphous alloy strip with soft magnetic properties.
3.3
oil-immersed amorphous alloy core power transformer
An oil-immersed power transformer with an amorphous alloy core as the magnetic circuit.
4 Performance parameters
Tables 1 to 6 specify the performance parameters of non-excitation tap-changing amorphous alloy core transformers of various voltage levels and corresponding capacities. They also calculate the peak efficiency (PEI) and the efficiency at 50 % load (EI50EI50) based on the efficiency calculation formula in GB/T 1094.20—2026, and list them in the tables.
The performance parameters of non-excitation tap-changing amorphous alloy core distribution transformers shall comply with the provisions of Tables 1 to 4.
The performance parameters of non-excitation tap-changing amorphous alloy core power transformers shall comply with the provisions of Tables 5 and 6.
If the voltage, tapping range, connection symbol or short-circuit impedance differs from the provisions in Tables 1 to 6, the relevant performance parameters shall be determined by agreement between the user and the manufacturer.
Note: For on-load tap-changing amorphous alloy core transformers, the performance parameters are generally reasonably determined by the user and the manufacturer with reference to the principles given in Annex A, based on the performance parameters of the same type of on-load tap-changing grain-oriented silicon steel core transformers and in combination with the comparison results of energy efficiency levels.
Table 1 — 6 kV, 10 kV class 5 kVA to 160 kVA single-phase non-excitation tap-changing amorphous alloy core distribution transformers
5 Technical requirements
5.1 General requirements
Transformers manufactured in accordance with this document shall comply with the provisions of GB/T 1094.1, GB/T 1094.2, GB/T 1094.3, GB/T 1094.5 and GB/T 1094.7.
In addition to complying with 5.2 and 5.3, transformers shall also comply with the provisions of 4.2, 5.2 and 6.2 in GB/T 6451—2023.
5.2 Sound level
The sound level of transformers [under oil-immersed self-cooling (ONAN) cooling mode] shall comply with the provisions of Table 7. The sound level measurement method shall be in accordance with the provisions of GB/T 1094.10.
Table 7 — Sound level
5.3 Stability of core performance
The transformer shall maintain the stability of core performance under normal operation, short circuit, and other impact forces. If necessary, relevant special test verifications may be carried out after negotiation between the user and the manufacturer; for example, transformer short-circuit withstand capability test, transformer transport bump test, etc.
6 Inspection rules and methods
6.1 General
The tests of transformers include routine tests, type tests and special tests. The test items, test requirements and test methods shall comply with the provisions of GB/T 1094.1 and JB/T 501.
In addition, the transformer shall also comply with the provisions of 6.2 and 6.3, and the provisions of 4.3.5.3 and 6.3 in GB/T 6451—2023.
6.2 Short-circuit withstand capability test
The short-circuit withstand capability test of the transformer shall be in accordance with the provisions of GB/T 1094.5.
The difference between the measured values of the no-load loss of the transformer before and after the short-circuit withstand capability test shall not exceed 12 %. The measurements shall be carried out in the same test room. At the same time, a lightning impulse test shall also be carried out during this phase.
6.3 Transport bump test
According to the agreement between the user and the manufacturer, the transformer may be subjected to a transport bump test. This test is a special test. The test methods and requirements shall be agreed upon by the user and the manufacturer.
7 Marking, lifting, packaging, transportation and storage
The marking, lifting, packaging, transportation and storage of transformers shall be in accordance with the provisions of 4.4, 5.4 and 6.4 in GB/T 6451—2023.