The test method of food detergents - Determination of heavy metals
1 Scope
This standard specifies the test method for determination of heavy metals in food detergents.
This standard is applicable to the determination of heavy metals (by Pb) in both food detergents and non-food detergents.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
GB/T 6682 Water for analytical laboratory use - Specification and test methods
3 Principle
Under weakly acidic conditions (pH=3~4), conduct the limit test by comparing the specimen in which the heavy metal ions react with hydrogen sulfide to generate a brownish-black substance with the lead (Pb) standard solution treated with the same method.
4 Reagents
Unless otherwise stated, only recognized analytically pure reagents and Grade III water as specified in GB/T 6682 shall be used in the analysis.
4.1 Hydrochloric acid.
4.2 Hydrochloric acid, c(HCl)=6mol/L: Measure 50mL hydrochloric acid and dilute it with water to 100mL.
Foreword i
1 Scope
2 Normative references
3 Principle
4 Reagents
5 Instruments
6 Pretreatment of specimen
7 Determination
Standard
GB/T 30799-2014 The test method of food detergents-Determination of heavy metals (English Version)
Standard No.
GB/T 30799-2014
Status
valid
Language
English
File Format
PDF
Word Count
4000 words
Price(USD)
100.0
Implemented on
2014-11-1
Delivery
via email in 1 business day
Detail of GB/T 30799-2014
Standard No.
GB/T 30799-2014
English Name
The test method of food detergents-Determination of heavy metals
The test method of food detergents - Determination of heavy metals
1 Scope
This standard specifies the test method for determination of heavy metals in food detergents.
This standard is applicable to the determination of heavy metals (by Pb) in both food detergents and non-food detergents.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
GB/T 6682 Water for analytical laboratory use - Specification and test methods
3 Principle
Under weakly acidic conditions (pH=3~4), conduct the limit test by comparing the specimen in which the heavy metal ions react with hydrogen sulfide to generate a brownish-black substance with the lead (Pb) standard solution treated with the same method.
4 Reagents
Unless otherwise stated, only recognized analytically pure reagents and Grade III water as specified in GB/T 6682 shall be used in the analysis.
4.1 Hydrochloric acid.
4.2 Hydrochloric acid, c(HCl)=6mol/L: Measure 50mL hydrochloric acid and dilute it with water to 100mL.
Contents of GB/T 30799-2014
Foreword i
1 Scope
2 Normative references
3 Principle
4 Reagents
5 Instruments
6 Pretreatment of specimen
7 Determination