GB/T 42709.36-2026 Semiconductor devices—Micro-electromechanical devices—Part 36:Environmental and dielectric withstand test methods for MEMS piezoelectric thin films (English)
This English text of GB/T 42709.36-2026 is translated by certified human translators, with proven quality
GB/T 42709.36-2026 Semiconductor devices—Micro-electromechanical devices—Part 36:Environmental and dielectric withstand test methods for MEMS piezoelectric thin films
1.Scope
This part of GB 42709 specifies test methods for evaluating the durability of MEMS piezoelectric thin film materials under the environmental stress of temperature and humidity and under electrical stress, and test conditions for appropriate quality assessment. Specifically, this document specifies test methods and test conditions for measuring the durability of a DUT under temperature and humidity conditions and applied voltages. It further applies to evaluations of converse piezoelectric properties in piezoelectric thin films formed primarily on silicon substrates, i.e., piezoelectric thin films used as actuators.
This document does not cover reliability assessments, such as methods of predicting the lifetime of a piezoelectric thin film based on a Weibull distribution.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
IEC 60068-2-14:2009 Environmental testing - Part 2-14: Tests - Test N: Change of temperature
IEC 62047-30 Semiconductor devices - Micro-electromechanical devices - Part 30: Measurement methods of electro-mechanical conversion characteristics of MEMS piezoelectric thin film
3 Terms and definitions
No terms and definitions are listed in this document.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
... ...
4 Testing procedure
4.1 General
The degree of degradation in a device under test (DUT) is evaluated by measuring the piezoelectric properties of the DUT before and after applying the environmental stress of temperature and humidity. Figure 1 shows the general flow of the testing procedure.
Figure 1 – Flow of the testing procedure
4.2 Initial measurements
The methods of measurement used in the environmental tests shall conform to the methods
described in IEC 62047-30. The ambient conditions for measurements shall include an
ambient temperature of 25℃ ± 3℃, a relative humidity of 45 % to 75 %, and an atmospheric pressure of 86 kPa to 106 kPa.
4.3 Tests
4.3.1 DUT setup and environmental conditions
For tests requiring continuous operation of the DUT, the DUT is placed in a test bed for adjusting the temperature and humidity to prescribed conditions. The test conditions are monitored to verify that no abnormalities occur when the chamber environment reaches the prescribed conditions. For tests that do not require continuous operations of the DUT, the DUT may be placed in the test bed and the test bed may be deposited in the chamber, but the test bed need not be put in the chamber. When depositing and removing the DUT and test bed for either test, the operator shall ensure that:
• water does not drip onto the DUT;
• the DUT is not directly immersed in water.
4.3.2 Test duration
See 5.1 .1 through 5.1 .7.
4.3.3 Number of tests and number of DUTs
Specifications for the number of tests and the number of DUTs shall take the failure mechanism, failure distribution, and other factors anticipated in each test into account. When intermediate measurements are required, such measurements may be performed according to the following timetable:
...
...
...
4.4 Post treatment
After completion of the tests, first the voltage is halted and then the DUT is removed from the chamber and returned to standard conditions. However, this shall not apply to cases in which the DUT clearly recovers from its degraded state after voltage is halted at the testing temperature because a correct result is not possible.
4.5 Final measurements
Standard
GB/T 42709.36-2026 Semiconductor devices—Micro-electromechanical devices—Part 36:Environmental and dielectric withstand test methods for MEMS piezoelectric thin films (English)
Standard No.
GB/T 42709.36-2026
Status
to be valid
Language
English
File Format
PDF
Word Count
8500 words
Translation Price(USD)
255.0
Implemented on
2027-2-1
Delivery
via email in 1~3 business day
Detail of GB/T 42709.36-2026
Standard No.
GB/T 42709.36-2026
English Name
Semiconductor devices—Micro-electromechanical devices—Part 36:Environmental and dielectric withstand test methods for MEMS piezoelectric thin films
GB/T 42709.36-2026 Semiconductor devices—Micro-electromechanical devices—Part 36:Environmental and dielectric withstand test methods for MEMS piezoelectric thin films
1.Scope
This part of GB 42709 specifies test methods for evaluating the durability of MEMS piezoelectric thin film materials under the environmental stress of temperature and humidity and under electrical stress, and test conditions for appropriate quality assessment. Specifically, this document specifies test methods and test conditions for measuring the durability of a DUT under temperature and humidity conditions and applied voltages. It further applies to evaluations of converse piezoelectric properties in piezoelectric thin films formed primarily on silicon substrates, i.e., piezoelectric thin films used as actuators.
This document does not cover reliability assessments, such as methods of predicting the lifetime of a piezoelectric thin film based on a Weibull distribution.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
IEC 60068-2-14:2009 Environmental testing - Part 2-14: Tests - Test N: Change of temperature
IEC 62047-30 Semiconductor devices - Micro-electromechanical devices - Part 30: Measurement methods of electro-mechanical conversion characteristics of MEMS piezoelectric thin film
3 Terms and definitions
No terms and definitions are listed in this document.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
... ...
4 Testing procedure
4.1 General
The degree of degradation in a device under test (DUT) is evaluated by measuring the piezoelectric properties of the DUT before and after applying the environmental stress of temperature and humidity. Figure 1 shows the general flow of the testing procedure.
Figure 1 – Flow of the testing procedure
4.2 Initial measurements
The methods of measurement used in the environmental tests shall conform to the methods
described in IEC 62047-30. The ambient conditions for measurements shall include an
ambient temperature of 25℃ ± 3℃, a relative humidity of 45 % to 75 %, and an atmospheric pressure of 86 kPa to 106 kPa.
4.3 Tests
4.3.1 DUT setup and environmental conditions
For tests requiring continuous operation of the DUT, the DUT is placed in a test bed for adjusting the temperature and humidity to prescribed conditions. The test conditions are monitored to verify that no abnormalities occur when the chamber environment reaches the prescribed conditions. For tests that do not require continuous operations of the DUT, the DUT may be placed in the test bed and the test bed may be deposited in the chamber, but the test bed need not be put in the chamber. When depositing and removing the DUT and test bed for either test, the operator shall ensure that:
• water does not drip onto the DUT;
• the DUT is not directly immersed in water.
4.3.2 Test duration
See 5.1 .1 through 5.1 .7.
4.3.3 Number of tests and number of DUTs
Specifications for the number of tests and the number of DUTs shall take the failure mechanism, failure distribution, and other factors anticipated in each test into account. When intermediate measurements are required, such measurements may be performed according to the following timetable:
...
...
...
4.4 Post treatment
After completion of the tests, first the voltage is halted and then the DUT is removed from the chamber and returned to standard conditions. However, this shall not apply to cases in which the DUT clearly recovers from its degraded state after voltage is halted at the testing temperature because a correct result is not possible.
4.5 Final measurements