GB/T 4706.89-2024 Safety of household and similar electrical appliances - Part 89:Particular requirements for high pressure cleaners and steam cleaners (English Version)
GB/T 4706.89-2024 Safety of household and similar electrical appliances - Part 89:Particular requirements for high pressure cleaners and steam cleaners
1 Scope
This clause of GB/T 4706.1-2024 is replaced by the following.
This document deals with the safety of high-pressure cleaners without traction drive, intended for household and commercial indoor or outdoor use, having a rated pressure not less than 2.5 MPa and not exceeding 35 MPa.
It also applies to steam cleaners and those parts of hot water high pressure cleaners incorporating a steam stage which have a capacity not exceeding 100 l, a rated pressure not exceeding 2.5 MPa and a product of capacity and rated pressure not exceeding 5 MPa·l.
They are not equipped with a traction drive. The following power systems of the drive for the high pressure pump are covered:
——mains powered motors up to a rated voltage of 250 V for single-phase machines and 480 V for other machines,
——battery-operated motors,
——internal combustion engines,
——hydraulic or pneumatic motors.
This standard does not apply to
——high pressure water jet machines having a rated pressure exceeding 35 MPa;
Note 101: In Europe, those machines are covered by EN 1829-1.
——steam cleaners intended for domestic use (IEC 60335-2-54);
——hand-held and transportable motor-operated electric tools (IEC 60745 series, IEC 61029 series, IEC 62841 series);
——appliances for medical purposes (IEC 60601);
——agricultural sprayers (ISO 4254-6);
——non-liquid, solid abrasive cleaners;
——machines designed to be part of a production process;
——machines designed for use in corrosive or explosive environments (dust, vapour or gas);
——machines designed for use in vehicles or on board of ships or aircraft.
Note 102: Attention is drawn to the fact that in many countries additional requirements on the safe use of the equipment covered can be specified by the national health authorities, the national authorities responsible for the protection of labour, the national water supply authorities and similar authorities.
2 Normative references
This clause of GB/T 4706.1-2024 is applicable except as follows.
Addition:
IEC 60364-1 Low-voltage electrical installations - Part 1: Fundamental principles, assessment of general characteristics, definitions
IEC 61558-2-3 Safety of transformers, reactors, power supply units and combinations thereof - Part 2-3: Particular requirements and tests for ignition transformers for gas and oil burners
IEC 61770:2008 Electric appliances connected to the water mains - Avoidance of backsiphonage and failure of hose-sets
3 Terms and definitions
This clause of GB/T 4706.1-2024 is applicable except as follows.
3.1.9 Replacement:
normal operation
conditions under which the machine is operated in normal use
It deNotes the operation at rated flow and rated pressure with the appropriate nozzle and hose line fitted, all strainers and filters in a clean operating condition and the unloader valve set to the rated pressure. The water heater, if fitted, is operated at maximum power. Electric motor driven machines are supplied at rated voltage.
Socket outlets for accessories are loaded with a resistive load in accordance with the marking.
The burner is operated at rated power. Machines designed for operation at more than one rated power setting are additionally tested at the most disadvantageous power.
On machines designed for use with a flue pipe, a section of flue pipe is attached to the machine. Flue gas determinations are taken in this flue pipe.
The draught is adjusted as recommended in the instructions.
3.1.12 Addition:
Functions not controlling the starting and stopping of the high pressure jet exiting the nozzle are not regarded as remote operation. Functions for other purposes e.g. detergent or water flow control are not considered to be remote operation.
3.101
unloader valve
pressure operated device which, when the pump pressure exceeds a preset value, releases the pressure and leads the excess fluid into the inlet system
In addition, it bypasses the total pump flow at reduced pressure when its outlet flow is cut off.
3.102
safety valve
pressure operated device which, when the pump or steam cleaner pressure exceeds a preset value, releases the pressure and which may return the excess fluid or steam either to the inlet system or into the atmosphere
3.103
rated pressure
maximum working pressure at the pressure generator during normal operatio
3.104
allowable pressure
maximum pressure up to which a machine and/or parts of the machine may be subjected without impairing its safety
3.105
rated flow
maximum flow at rated pressure at the nozzle during normal operation
3.106
maximum flow rate
highest possible flow rate at the nozzle
Note: Typically, the maximum flow rate occurs at working pressures lower than rated pressure and with a nozzle designed for spraying of cleaning agents.
3.107
rated temperature
maximum temperature of the cleaning agent during normal operation
3.108
pressure switch
device which, in response to varying fluid pressure, provides a controlling function at a pre-set value
3.109
flow switch
device which, in response to a varying rate of fluid flow, provides a controlling function at a pre-set value
3.110
trigger gun
hand-held spraying device where the flow of the cleaning agent is regulated by an integrated manually operated control device
3.111
pencil jet nozzle
nozzle that gives a concentrated, parallel water jet
Note: Pencil jet nozzles are also known as needle jet nozzles, solid jet nozzles or 0 degree jet nozzles.
3.112
water jetter
pipe-cleaning device, connected to and controlled by a trigger gun, consisting of a high pressure hose and a cleaning head with nozzles
Standard
GB/T 4706.89-2024 Safety of household and similar electrical appliances - Part 89:Particular requirements for high pressure cleaners and steam cleaners (English Version)
Standard No.
GB/T 4706.89-2024
Status
to be valid
Language
English
File Format
PDF
Word Count
26500 words
Price(USD)
795.0
Implemented on
2026-8-1
Delivery
via email in 1~3 business day
Detail of GB/T 4706.89-2024
Standard No.
GB/T 4706.89-2024
English Name
Safety of household and similar electrical appliances - Part 89:Particular requirements for high pressure cleaners and steam cleaners
Chinese Name
家用和类似用途电器的安全 第89部分:高压清洁器和蒸汽清洁器的特殊要求
Chinese Classification
Professional Classification
GB
ICS Classification
Issued by
State Administration for Market Regulation; Standardization Administration of China
GB/T 4706.89-2024 Safety of household and similar electrical appliances - Part 89:Particular requirements for high pressure cleaners and steam cleaners
1 Scope
This clause of GB/T 4706.1-2024 is replaced by the following.
This document deals with the safety of high-pressure cleaners without traction drive, intended for household and commercial indoor or outdoor use, having a rated pressure not less than 2.5 MPa and not exceeding 35 MPa.
It also applies to steam cleaners and those parts of hot water high pressure cleaners incorporating a steam stage which have a capacity not exceeding 100 l, a rated pressure not exceeding 2.5 MPa and a product of capacity and rated pressure not exceeding 5 MPa·l.
They are not equipped with a traction drive. The following power systems of the drive for the high pressure pump are covered:
——mains powered motors up to a rated voltage of 250 V for single-phase machines and 480 V for other machines,
——battery-operated motors,
——internal combustion engines,
——hydraulic or pneumatic motors.
This standard does not apply to
——high pressure water jet machines having a rated pressure exceeding 35 MPa;
Note 101: In Europe, those machines are covered by EN 1829-1.
——steam cleaners intended for domestic use (IEC 60335-2-54);
——hand-held and transportable motor-operated electric tools (IEC 60745 series, IEC 61029 series, IEC 62841 series);
——appliances for medical purposes (IEC 60601);
——agricultural sprayers (ISO 4254-6);
——non-liquid, solid abrasive cleaners;
——machines designed to be part of a production process;
——machines designed for use in corrosive or explosive environments (dust, vapour or gas);
——machines designed for use in vehicles or on board of ships or aircraft.
Note 102: Attention is drawn to the fact that in many countries additional requirements on the safe use of the equipment covered can be specified by the national health authorities, the national authorities responsible for the protection of labour, the national water supply authorities and similar authorities.
2 Normative references
This clause of GB/T 4706.1-2024 is applicable except as follows.
Addition:
IEC 60364-1 Low-voltage electrical installations - Part 1: Fundamental principles, assessment of general characteristics, definitions
IEC 61558-2-3 Safety of transformers, reactors, power supply units and combinations thereof - Part 2-3: Particular requirements and tests for ignition transformers for gas and oil burners
IEC 61770:2008 Electric appliances connected to the water mains - Avoidance of backsiphonage and failure of hose-sets
3 Terms and definitions
This clause of GB/T 4706.1-2024 is applicable except as follows.
3.1.9 Replacement:
normal operation
conditions under which the machine is operated in normal use
It deNotes the operation at rated flow and rated pressure with the appropriate nozzle and hose line fitted, all strainers and filters in a clean operating condition and the unloader valve set to the rated pressure. The water heater, if fitted, is operated at maximum power. Electric motor driven machines are supplied at rated voltage.
Socket outlets for accessories are loaded with a resistive load in accordance with the marking.
The burner is operated at rated power. Machines designed for operation at more than one rated power setting are additionally tested at the most disadvantageous power.
On machines designed for use with a flue pipe, a section of flue pipe is attached to the machine. Flue gas determinations are taken in this flue pipe.
The draught is adjusted as recommended in the instructions.
3.1.12 Addition:
Functions not controlling the starting and stopping of the high pressure jet exiting the nozzle are not regarded as remote operation. Functions for other purposes e.g. detergent or water flow control are not considered to be remote operation.
3.101
unloader valve
pressure operated device which, when the pump pressure exceeds a preset value, releases the pressure and leads the excess fluid into the inlet system
In addition, it bypasses the total pump flow at reduced pressure when its outlet flow is cut off.
3.102
safety valve
pressure operated device which, when the pump or steam cleaner pressure exceeds a preset value, releases the pressure and which may return the excess fluid or steam either to the inlet system or into the atmosphere
3.103
rated pressure
maximum working pressure at the pressure generator during normal operatio
3.104
allowable pressure
maximum pressure up to which a machine and/or parts of the machine may be subjected without impairing its safety
3.105
rated flow
maximum flow at rated pressure at the nozzle during normal operation
3.106
maximum flow rate
highest possible flow rate at the nozzle
Note: Typically, the maximum flow rate occurs at working pressures lower than rated pressure and with a nozzle designed for spraying of cleaning agents.
3.107
rated temperature
maximum temperature of the cleaning agent during normal operation
3.108
pressure switch
device which, in response to varying fluid pressure, provides a controlling function at a pre-set value
3.109
flow switch
device which, in response to a varying rate of fluid flow, provides a controlling function at a pre-set value
3.110
trigger gun
hand-held spraying device where the flow of the cleaning agent is regulated by an integrated manually operated control device
3.111
pencil jet nozzle
nozzle that gives a concentrated, parallel water jet
Note: Pencil jet nozzles are also known as needle jet nozzles, solid jet nozzles or 0 degree jet nozzles.
3.112
water jetter