2023-3-27 3.238.134.157
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB/T 5023.2-2008
GB/T 5023.2-2008   Polyvinyl chloride insulated cables of rated voltages up to and including 450/750V - Part 2: Test methods (English Version)
Standard No.: GB/T 5023.2-2008 Status:valid remind me the status change

Email:

Language:English File Format:PDF
Word Count: 4500 words Price(USD):100.0 remind me the price change

Email:

Implemented on:2009-5-1 Delivery: via email in 1~3 business day
,,
Standard No.: GB/T 5023.2-2008
English Name: Polyvinyl chloride insulated cables of rated voltages up to and including 450/750V - Part 2: Test methods
Chinese Name: 额定电压450/750V及以下聚氯乙烯绝缘电缆 第2部分:试验方法
Chinese Classification: K13    Cable and its accessory
Professional Classification: GB    National Standard
ICS Classification: 29.060.20 29.060.20    Cables 29.060.20
Issued by: AQSIQ, SAC
Issued on: 2008-6-30
Implemented on: 2009-5-1
Status: valid
Superseding:GB 5023.2-1997 Polyvinyl chloride insulated cables of rated voltages up to and including 450 / 750V - Part 2: Test methods
Language: English
File Format: PDF
Word Count: 4500 words
Price(USD): 100.0
Delivery: via email in 1~3 business day
GB/T 5023《额定电压450/750V及以下聚氯乙烯绝缘电缆》分为七个部分,本部分为GB/T 5023的第2部分。本部分等同采用IEC 60227-2:2003《额定电压450/750V及以下聚氯乙烯绝缘电缆 第2部分:试验方法》第2.1版(英文版)。
本部分代替GB 5023.2-1997《额定电压450/750V及以下聚氯乙烯绝缘电缆 第2部分:试验方法》。
本部分与GB 5023.2-1997相比主要变化如下:
——1.9.1中取消了“将一段绝缘线芯试样浸入水银中,直至绝缘变得松驰,能把导体抽出”方法;
——删除了2.3、表1及3.4中“扁形无护套软线”的相关内容;
——3.1曲挠试验作了以下修改:
1)3.1.1总则中修改为“本试验也不适用于线芯标称截面积大于2.5mm2多芯软电缆”;
2)3.1.2对曲挠试验仪器作了描述;
3)3.1.3试样准备的表1中电缆芯数增加2、3、4芯,并规定2、3、4芯标称截面积为0.5mm2
的电缆挂重为0.5kg,滑轮的直径为60mm;
4) 增加了3.1.4线芯载流试验;
5) 增加了3.1.5线芯间电压试验;
6) 增加了3.1.6失效检查。
——增加了3.5静态曲挠试验;
——增加了3.6电梯电缆中心垫芯的抗张强度试验。
GB/T 5023.2-2008 is referred in:
*CQC 1103-2015 Technical Specification for Cables of Electric Vehicles Conductive Charging Systems Part 1: General Requiremen
*JB/T 8734.1-2016 Polyvinyl chloride insulated cables and wires and cords of rated voltages up to and including 450/750V — Part 1:General requirements
*JB/T 8734.2-2016 Polyvinyl chloride insulated cables and wires and cords of rated voltages up to and including 450/750V — Part 2:Insulated cables and wires for fixed wiring
*JB/T 8734.5-2016 Polyvinyl chloride insulated cables and wires and cords of rated voltages up to and including 450/750V — Part 5: Screened wires
Code of China
Standard
GB/T 5023.2-2008  Polyvinyl chloride insulated cables of rated voltages up to and including 450/750V - Part 2: Test methods (English Version)
Standard No.GB/T 5023.2-2008
Statusvalid
LanguageEnglish
File FormatPDF
Word Count4500 words
Price(USD)100.0
Implemented on2009-5-1
Deliveryvia email in 1~3 business day
Detail of GB/T 5023.2-2008
Standard No.
GB/T 5023.2-2008
English Name
Polyvinyl chloride insulated cables of rated voltages up to and including 450/750V - Part 2: Test methods
Chinese Name
额定电压450/750V及以下聚氯乙烯绝缘电缆 第2部分:试验方法
Chinese Classification
K13
Professional Classification
GB
ICS Classification
Issued by
AQSIQ, SAC
Issued on
2008-6-30
Implemented on
2009-5-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
GB 5023.2-1997 Polyvinyl chloride insulated cables of rated voltages up to and including 450 / 750V - Part 2: Test methods
Language
English
File Format
PDF
Word Count
4500 words
Price(USD)
100.0
Keywords
GB/T 5023.2-2008, GB 5023.2-2008, GBT 5023.2-2008, GB/T5023.2-2008, GB/T 5023.2, GB/T5023.2, GB5023.2-2008, GB 5023.2, GB5023.2, GBT5023.2-2008, GBT 5023.2, GBT5023.2
Introduction of GB/T 5023.2-2008
GB/T 5023《额定电压450/750V及以下聚氯乙烯绝缘电缆》分为七个部分,本部分为GB/T 5023的第2部分。本部分等同采用IEC 60227-2:2003《额定电压450/750V及以下聚氯乙烯绝缘电缆 第2部分:试验方法》第2.1版(英文版)。
本部分代替GB 5023.2-1997《额定电压450/750V及以下聚氯乙烯绝缘电缆 第2部分:试验方法》。
本部分与GB 5023.2-1997相比主要变化如下:
——1.9.1中取消了“将一段绝缘线芯试样浸入水银中,直至绝缘变得松驰,能把导体抽出”方法;
——删除了2.3、表1及3.4中“扁形无护套软线”的相关内容;
——3.1曲挠试验作了以下修改:
1)3.1.1总则中修改为“本试验也不适用于线芯标称截面积大于2.5mm2多芯软电缆”;
2)3.1.2对曲挠试验仪器作了描述;
3)3.1.3试样准备的表1中电缆芯数增加2、3、4芯,并规定2、3、4芯标称截面积为0.5mm2
的电缆挂重为0.5kg,滑轮的直径为60mm;
4) 增加了3.1.4线芯载流试验;
5) 增加了3.1.5线芯间电压试验;
6) 增加了3.1.6失效检查。
——增加了3.5静态曲挠试验;
——增加了3.6电梯电缆中心垫芯的抗张强度试验。
Contents of GB/T 5023.2-2008
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Foryou Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 5023.2-2008, GB 5023.2-2008, GBT 5023.2-2008, GB/T5023.2-2008, GB/T 5023.2, GB/T5023.2, GB5023.2-2008, GB 5023.2, GB5023.2, GBT5023.2-2008, GBT 5023.2, GBT5023.2