2025-12-5 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB/T 5195.12-2025
GB/T 5195.12-2025   Methods for chemical analysis of fluorspar—Part 12: Determination of arsenic content (English Version)
Standard No.: GB/T 5195.12-2025 Status:to be valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 9000 words Translation Price(USD):270.0 remind me the price change

Email:

Implemented on:2026-3-1 Delivery: via email in 1~3 business day

→ → →

,,2026-3-1,3E386865F904F18B1756977105511
Standard No.: GB/T 5195.12-2025
English Name: Methods for chemical analysis of fluorspar—Part 12: Determination of arsenic content
Chinese Name: 萤石化学分析方法 第12部分:砷含量的测定
Chinese Classification: D52    Metallurgical auxiliary material ore
Professional Classification: GB    National Standard
Source Content Issued by: SAMR; SAC
Issued on: 2025-8-29
Implemented on: 2026-3-1
Status: to be valid
Superseding:GB/T 5195.12-2016 Fluorite―Determination of arsenic content―Atomic fluorescence spectrometry
GB/T 5195.19-2018 Fluorspar—Determination of arsenic content—Silver diethyldithiocarbamate spectrometric method
Target Language: English
File Format: PDF
Word Count: 9000 words
Translation Price(USD): 270.0
Delivery: via email in 1~3 business day
GB/T 5195.12-2025 Methods for chemical analysis of fluorspar—Part 12: Determination of arsenic content English, Anglais, Englisch, Inglés, えいご This is a draft translation for reference among interesting stakeholders. The finalized translation (passing thorugh draft translation, self-check, revision and varification) will be delivered upon being ordered. ICS 73.080 CCS D 52 National Standard of the People's Republic of China GB/T 5195.12-2025 Replace GB/T 5195.12-2016, GB/T 5195.19-2018 Methods for Chemical Analysis of Fluorspar— Part 12: Determination of Arsenic Content Issued: 2025-08-29 Implemented: 2026-03-01 Issued by: State Administration for Market Regulation Standardization Administration of China Contents Foreword Introduction 1 Scope 2 Normative References 3 Terms and Definitions 4 Method 1: Atomic Fluorescence Spectrometry 5 Method 2: Silver Diethyldithiocarbamate Photometry 6 Test Report Methods for Chemical Analysis of Fluorspar—Part 12: Determination of Arsenic Content Warning—Personnel using this document shall have formal laboratory working experience. This document does not indicate all possible safety issues. Users are responsible for taking appropriate safety and health measures and ensuring compliance with relevant national regulations. 1 Scope This document describes methods for the determination of arsenic content in fluorspar, including atomic fluorescence spectrometry (Method 1) and silver diethyldithiocarbamate photometry (Method 2). This document is applicable for the determination of arsenic content in fluorspar. The determination range of atomic fluorescence spectrometry (mass fraction): 0.000010% to 0.0100%; the determination range of silver diethyldithiocarbamate photometry (mass fraction): 0.00020% to 0.0500%. 2 Normative References The following documents contain provisions which, through reference in this text, constitute essential provisions of this document. For dated references, only the editions cited apply; for undated references, the latest edition (including any amendments) applies. GB/T 6379.1 Accuracy (trueness and precision) of measurement methods and results—Part 1: General principles and definitions GB/T 6379.2 Accuracy (trueness and precision) of measurement methods and results—Part 2: Basic method for the determination of repeatability and reproducibility of standard measurement methods GB/T 6682 Specification and test methods for water for analytical laboratory GB/T 8170 Rules for rounding off numerical values and expression of limiting values GB/T 12806 Laboratory glassware—Volumetric flasks GB/T 12807 Laboratory glassware—Graduated pipettes GB/T 12808 Laboratory glassware—Single-mark volumetric pipettes GB/T 21191 Atomic fluorescence spectrometer GB/T 22564 Fluorspar—Sampling and sample preparation 3 Terms and Definitions No terms and definitions need to be defined in this document. 4 Method 1: Atomic Fluorescence Spectrometry 4.1 Principle The test sample is dissolved with nitric acid and perchloric acid. In dilute hydrochloric acid medium, arsenic(V) is reduced to arsenic(III) by adding thiourea-ascorbic acid mixed solution. In the hydride generator, arsenic is reduced to hydride by potassium borohydride, introduced into the quartz furnace atomizer by argon, and the fluorescence intensity of arsenic is measured on the atomic fluorescence spectrometer. The arsenic content is calculated by the standard curve method. 4.2 Reagents and Materials Only analytical grade or higher purity reagents recognized in the analysis shall be used, and only water of grade II or equivalent purity as specified in GB/T 6682 shall be used. 4.2.1 Potassium borohydride. 4.2.2 Sodium hydroxide. 4.2.3 Thiourea. 4.2.4 Ascorbic acid. 4.2.5 Hydrochloric acid, ρ about 1.19 g/mL. 4.2.6 Nitric acid, ρ about 1.42 g/mL. 4.2.7 Perchloric acid, ρ about 1.76 g/mL. 4.2.8 Hydrochloric acid, 1+1. 4.2.9 Hydrochloric acid, 1+19. 4.2.10 Nitric acid, 1+9. 4.2.11 Sodium hydroxide solution, 100 g/L. 4.2.12 Phenolphthalein ethanol solution, 1 g/L. 4.2.13 Potassium borohydride solution, 20 g/L: Weigh 10.0 g of potassium borohydride and 2.5 g of sodium hydroxide, dissolve in water and dilute to 500 mL. Prepare fresh before use. 4.2.14 Thiourea-ascorbic acid solution, 50 g/L: Weigh 5.0 g each of thiourea and ascorbic acid, dissolve in water and dilute to 100 mL. Prepare fresh before use. 4.2.15 Arsenic standard stock solution, 100 μg/mL: Accurately weigh 0.132 0 g of primary arsenic trioxide dried at 100 ℃ to 105 ℃ for 1 h and cooled to room temperature in a desiccator in a 100 mL beaker, add 10 mL of sodium hydroxide solution (4.2.11), heat at low temperature to dissolve, add 10 mL of water and 2 drops of phenolphthalein ethanol solution (4.2.12), neutralize with hydrochloric acid (4.2.8) until the red color just disappears, then add 5 mL in excess, transfer to a 1 000 mL volumetric flask, dilute to volume with water and mix. This solution contains 100 μg of arsenic per mL. Or use certified standard solutions. 4.2.16 Arsenic standard solution, 1 μg/mL: Pipette 1.00 mL of arsenic standard stock solution (4.2.15) into a 100 mL volumetric flask, add 5 mL of nitric acid (4.2.6), dilute to volume with water and mix. This solution contains 1.00 μg of arsenic per mL. 4.2.17 Arsenic standard solution, 10 ng/mL: Pipette 1.00 mL of arsenic standard solution (4.2.16) into a 100 mL volumetric flask, add 5 mL of nitric acid (4.2.6), dilute to volume with water and mix. This solution contains 10 ng of arsenic per mL. 4.2.18 Argon, purity greater than 99.99%.
Code of China
Standard
GB/T 5195.12-2025  Methods for chemical analysis of fluorspar—Part 12: Determination of arsenic content (English Version)
Standard No.GB/T 5195.12-2025
Statusto be valid
LanguageEnglish
File FormatPDF
Word Count9000 words
Price(USD)270.0
Implemented on2026-3-1
Deliveryvia email in 1~3 business day
Detail of GB/T 5195.12-2025
Standard No.
GB/T 5195.12-2025
English Name
Methods for chemical analysis of fluorspar—Part 12: Determination of arsenic content
Chinese Name
萤石化学分析方法 第12部分:砷含量的测定
Chinese Classification
D52
Professional Classification
GB
ICS Classification
Issued by
SAMR; SAC
Issued on
2025-8-29
Implemented on
2026-3-1
Status
to be valid
Superseded by
Superseded on
Abolished on
Superseding
GB/T 5195.12-2016 Fluorite―Determination of arsenic content―Atomic fluorescence spectrometry
GB/T 5195.19-2018 Fluorspar—Determination of arsenic content—Silver diethyldithiocarbamate spectrometric method
Language
English
File Format
PDF
Word Count
9000 words
Price(USD)
270.0
Keywords
GB/T 5195.12-2025, GB 5195.12-2025, GBT 5195.12-2025, GB/T5195.12-2025, GB/T 5195.12, GB/T5195.12, GB5195.12-2025, GB 5195.12, GB5195.12, GBT5195.12-2025, GBT 5195.12, GBT5195.12
Introduction of GB/T 5195.12-2025
GB/T 5195.12-2025 Methods for chemical analysis of fluorspar—Part 12: Determination of arsenic content English, Anglais, Englisch, Inglés, えいご This is a draft translation for reference among interesting stakeholders. The finalized translation (passing thorugh draft translation, self-check, revision and varification) will be delivered upon being ordered. ICS 73.080 CCS D 52 National Standard of the People's Republic of China GB/T 5195.12-2025 Replace GB/T 5195.12-2016, GB/T 5195.19-2018 Methods for Chemical Analysis of Fluorspar— Part 12: Determination of Arsenic Content Issued: 2025-08-29 Implemented: 2026-03-01 Issued by: State Administration for Market Regulation Standardization Administration of China Contents Foreword Introduction 1 Scope 2 Normative References 3 Terms and Definitions 4 Method 1: Atomic Fluorescence Spectrometry 5 Method 2: Silver Diethyldithiocarbamate Photometry 6 Test Report Methods for Chemical Analysis of Fluorspar—Part 12: Determination of Arsenic Content Warning—Personnel using this document shall have formal laboratory working experience. This document does not indicate all possible safety issues. Users are responsible for taking appropriate safety and health measures and ensuring compliance with relevant national regulations. 1 Scope This document describes methods for the determination of arsenic content in fluorspar, including atomic fluorescence spectrometry (Method 1) and silver diethyldithiocarbamate photometry (Method 2). This document is applicable for the determination of arsenic content in fluorspar. The determination range of atomic fluorescence spectrometry (mass fraction): 0.000010% to 0.0100%; the determination range of silver diethyldithiocarbamate photometry (mass fraction): 0.00020% to 0.0500%. 2 Normative References The following documents contain provisions which, through reference in this text, constitute essential provisions of this document. For dated references, only the editions cited apply; for undated references, the latest edition (including any amendments) applies. GB/T 6379.1 Accuracy (trueness and precision) of measurement methods and results—Part 1: General principles and definitions GB/T 6379.2 Accuracy (trueness and precision) of measurement methods and results—Part 2: Basic method for the determination of repeatability and reproducibility of standard measurement methods GB/T 6682 Specification and test methods for water for analytical laboratory GB/T 8170 Rules for rounding off numerical values and expression of limiting values GB/T 12806 Laboratory glassware—Volumetric flasks GB/T 12807 Laboratory glassware—Graduated pipettes GB/T 12808 Laboratory glassware—Single-mark volumetric pipettes GB/T 21191 Atomic fluorescence spectrometer GB/T 22564 Fluorspar—Sampling and sample preparation 3 Terms and Definitions No terms and definitions need to be defined in this document. 4 Method 1: Atomic Fluorescence Spectrometry 4.1 Principle The test sample is dissolved with nitric acid and perchloric acid. In dilute hydrochloric acid medium, arsenic(V) is reduced to arsenic(III) by adding thiourea-ascorbic acid mixed solution. In the hydride generator, arsenic is reduced to hydride by potassium borohydride, introduced into the quartz furnace atomizer by argon, and the fluorescence intensity of arsenic is measured on the atomic fluorescence spectrometer. The arsenic content is calculated by the standard curve method. 4.2 Reagents and Materials Only analytical grade or higher purity reagents recognized in the analysis shall be used, and only water of grade II or equivalent purity as specified in GB/T 6682 shall be used. 4.2.1 Potassium borohydride. 4.2.2 Sodium hydroxide. 4.2.3 Thiourea. 4.2.4 Ascorbic acid. 4.2.5 Hydrochloric acid, ρ about 1.19 g/mL. 4.2.6 Nitric acid, ρ about 1.42 g/mL. 4.2.7 Perchloric acid, ρ about 1.76 g/mL. 4.2.8 Hydrochloric acid, 1+1. 4.2.9 Hydrochloric acid, 1+19. 4.2.10 Nitric acid, 1+9. 4.2.11 Sodium hydroxide solution, 100 g/L. 4.2.12 Phenolphthalein ethanol solution, 1 g/L. 4.2.13 Potassium borohydride solution, 20 g/L: Weigh 10.0 g of potassium borohydride and 2.5 g of sodium hydroxide, dissolve in water and dilute to 500 mL. Prepare fresh before use. 4.2.14 Thiourea-ascorbic acid solution, 50 g/L: Weigh 5.0 g each of thiourea and ascorbic acid, dissolve in water and dilute to 100 mL. Prepare fresh before use. 4.2.15 Arsenic standard stock solution, 100 μg/mL: Accurately weigh 0.132 0 g of primary arsenic trioxide dried at 100 ℃ to 105 ℃ for 1 h and cooled to room temperature in a desiccator in a 100 mL beaker, add 10 mL of sodium hydroxide solution (4.2.11), heat at low temperature to dissolve, add 10 mL of water and 2 drops of phenolphthalein ethanol solution (4.2.12), neutralize with hydrochloric acid (4.2.8) until the red color just disappears, then add 5 mL in excess, transfer to a 1 000 mL volumetric flask, dilute to volume with water and mix. This solution contains 100 μg of arsenic per mL. Or use certified standard solutions. 4.2.16 Arsenic standard solution, 1 μg/mL: Pipette 1.00 mL of arsenic standard stock solution (4.2.15) into a 100 mL volumetric flask, add 5 mL of nitric acid (4.2.6), dilute to volume with water and mix. This solution contains 1.00 μg of arsenic per mL. 4.2.17 Arsenic standard solution, 10 ng/mL: Pipette 1.00 mL of arsenic standard solution (4.2.16) into a 100 mL volumetric flask, add 5 mL of nitric acid (4.2.6), dilute to volume with water and mix. This solution contains 10 ng of arsenic per mL. 4.2.18 Argon, purity greater than 99.99%.
Contents of GB/T 5195.12-2025
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 5195.12-2025, GB 5195.12-2025, GBT 5195.12-2025, GB/T5195.12-2025, GB/T 5195.12, GB/T5195.12, GB5195.12-2025, GB 5195.12, GB5195.12, GBT5195.12-2025, GBT 5195.12, GBT5195.12