Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative.
GB/T 5584 consists of the following four parts under the general title Rectangular copper or aluminium and its alloy wires for electrical purposes:
——Part 1: General;
——Part 2: Rectangular copper and copper alloy wire;
——Part 3: Aluminium rectangular wire;
——Part 4: Strip copper conductor.
This part is Part 4 of GB/T 5584.
This part is developed in accordance with the rules given in GB/T 1.1-2009.
This standard replaces GB/T 5584.4-2009 Rectangular copper or aluminium and its alloy wires for electrical purposes–Part 4: Strip copper conductor and the following main technical changes have been made with respect to GB/T 5584.4-2009:
——The technical requirements for phosphorized copper TP1DR are added (see Clause 3 hereof);
——Vickers hardness requirements for strip copper conductor are added (see 3.6 hereof);
——The dimension range of strip copper conductor is modified (see 3.2 hereof; 5.2 of Edition 2009);
——The specification of strip copper conductor is deleted (see Clause 5 of Edition 2009).
This part was proposed by the China Electrical Equipment Industry Association.
This part is under the jurisdiction of SAC/TC 422 National Technical Committee on Bare Wires of Standardization Administration of China.
The previous editions of this part are as follows:
——GB/T 5584.4-1985 and GB/T 5584.4-2009.
Rectangular copper or aluminium and its alloy wires for electrical purposes—
Part 4: Strip copper conductor
1 Scope
This part of GB/T 5584 specifies the technical requirements, test and inspection rules and delivery requirements of strip copper conductor for electrical purposes.
It is applicable to strip copper conductor for electrical purposes.
2 Normative references
The following referenced documents are indispensable for the purpose of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
GB/T 3048.2 Test methods for electrical properties of electric cables and wires—Part 2: Test of electrical resistivity of metallic materials
GB/T 4340.1 Metallic materials—Vickers hardness test—Part 1: Test method
GB/T 4909.2 Test methods for bare wires—Part 2: Measurement of dimensions
GB/T 4909.3 Test methods for bare wires—Part 3: Tensile test
GB/T 4909.6 Test methods for bare wires—Part 6: Bend test—Single bend test
GB/T 5121 (all parts) Methods for chemical analysis of copper and copper alloys
GB/T 5584.1-2020 Rectangular copper or aluminium and its alloy wires for electrical purposes—Part 1: General
3 Technical requirements
3.1 Chemical compositions
The chemical compositions of strip copper conductor shall meet those specified in Table 1.
Table 1 Chemical compositions of strip copper conductor
Product category Mass fraction/%
Cu + Ag, ≥ P
TDR, TDY1, TDY2 99.90 —
TP1DR 99.90 0.004–0.012
Note: In case of any special requirement for chemical compositions, it shall be determined through negotiation between the supplier and the purchaser.
3.2 Dimension and deviation
3.2.1 The dimension ranges of strip copper conductor are as follows:
——Narrow edge: 0.30 mm ≤ a ≤ 3.55 mm;
——Wide edge: 9.00 mm ≤ b ≤ 100.00 mm.
3.2.2 The dimensions and deviations of narrow edge a and wide edge b of strip copper conductor shall meet those specified in Table 2.
Table 2 Dimensions and deviations In: mm
Narrow edge a Deviation Wide edge b Deviation
0.30 ≤ a ≤ 0.80 ± 0.020 9.00 ≤ b ≤ 25.00 ± 0.100
0.80 < a ≤ 1.25 ± 0.030 25.00 < b ≤ 50.00 ± 0.120
1.25 < a ≤ 1.80 ± 0.040 50.00 < b ≤ 100.00 ± 0.250
1.80 < a ≤ 3.55 ± 0.050 — —
3.3 Radius of round corners and edges
The radius of round corners and round edges of the strip copper conductor shall meet the requirements of GB/T 5584.1-2020, 7.3.
3.4 Tensile strength and elongation
The tensile strength and elongation of the strip copper conductor shall meet those specified in Table 3.
Foreword i
1 Scope
2 Normative references
3 Technical requirements
4 Test and inspection rules
5 Delivery requirements
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative.
GB/T 5584 consists of the following four parts under the general title Rectangular copper or aluminium and its alloy wires for electrical purposes:
——Part 1: General;
——Part 2: Rectangular copper and copper alloy wire;
——Part 3: Aluminium rectangular wire;
——Part 4: Strip copper conductor.
This part is Part 4 of GB/T 5584.
This part is developed in accordance with the rules given in GB/T 1.1-2009.
This standard replaces GB/T 5584.4-2009 Rectangular copper or aluminium and its alloy wires for electrical purposes–Part 4: Strip copper conductor and the following main technical changes have been made with respect to GB/T 5584.4-2009:
——The technical requirements for phosphorized copper TP1DR are added (see Clause 3 hereof);
——Vickers hardness requirements for strip copper conductor are added (see 3.6 hereof);
——The dimension range of strip copper conductor is modified (see 3.2 hereof; 5.2 of Edition 2009);
——The specification of strip copper conductor is deleted (see Clause 5 of Edition 2009).
This part was proposed by the China Electrical Equipment Industry Association.
This part is under the jurisdiction of SAC/TC 422 National Technical Committee on Bare Wires of Standardization Administration of China.
The previous editions of this part are as follows:
——GB/T 5584.4-1985 and GB/T 5584.4-2009.
Rectangular copper or aluminium and its alloy wires for electrical purposes—
Part 4: Strip copper conductor
1 Scope
This part of GB/T 5584 specifies the technical requirements, test and inspection rules and delivery requirements of strip copper conductor for electrical purposes.
It is applicable to strip copper conductor for electrical purposes.
2 Normative references
The following referenced documents are indispensable for the purpose of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
GB/T 3048.2 Test methods for electrical properties of electric cables and wires—Part 2: Test of electrical resistivity of metallic materials
GB/T 4340.1 Metallic materials—Vickers hardness test—Part 1: Test method
GB/T 4909.2 Test methods for bare wires—Part 2: Measurement of dimensions
GB/T 4909.3 Test methods for bare wires—Part 3: Tensile test
GB/T 4909.6 Test methods for bare wires—Part 6: Bend test—Single bend test
GB/T 5121 (all parts) Methods for chemical analysis of copper and copper alloys
GB/T 5584.1-2020 Rectangular copper or aluminium and its alloy wires for electrical purposes—Part 1: General
3 Technical requirements
3.1 Chemical compositions
The chemical compositions of strip copper conductor shall meet those specified in Table 1.
Table 1 Chemical compositions of strip copper conductor
Product category Mass fraction/%
Cu + Ag, ≥ P
TDR, TDY1, TDY2 99.90 —
TP1DR 99.90 0.004–0.012
Note: In case of any special requirement for chemical compositions, it shall be determined through negotiation between the supplier and the purchaser.
3.2 Dimension and deviation
3.2.1 The dimension ranges of strip copper conductor are as follows:
——Narrow edge: 0.30 mm ≤ a ≤ 3.55 mm;
——Wide edge: 9.00 mm ≤ b ≤ 100.00 mm.
3.2.2 The dimensions and deviations of narrow edge a and wide edge b of strip copper conductor shall meet those specified in Table 2.
Table 2 Dimensions and deviations In: mm
Narrow edge a Deviation Wide edge b Deviation
0.30 ≤ a ≤ 0.80 ± 0.020 9.00 ≤ b ≤ 25.00 ± 0.100
0.80 < a ≤ 1.25 ± 0.030 25.00 < b ≤ 50.00 ± 0.120
1.25 < a ≤ 1.80 ± 0.040 50.00 < b ≤ 100.00 ± 0.250
1.80 < a ≤ 3.55 ± 0.050 — —
3.3 Radius of round corners and edges
The radius of round corners and round edges of the strip copper conductor shall meet the requirements of GB/T 5584.1-2020, 7.3.
3.4 Tensile strength and elongation
The tensile strength and elongation of the strip copper conductor shall meet those specified in Table 3.
Contents of GB/T 5584.4-2020
Foreword i
1 Scope
2 Normative references
3 Technical requirements
4 Test and inspection rules
5 Delivery requirements