2025-12-5 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/JB/T 9548.4-1999
JB/T 9548.4-1999   Methods for chemical analysis of iron-chromium-aluminium alloys The photometric acid dehydration gravimetric mehtod for the determination of silicon content (English Version)
Standard No.: JB/T 9548.4-1999 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 2000 words Translation Price(USD):164.0 remind me the price change

Email:

Implemented on:2000-1-1 Delivery: via email in 1 business day

→ → →

,,2000-1-1,141137343688431B3D135B091957E
Standard No.: JB/T 9548.4-1999
English Name: Methods for chemical analysis of iron-chromium-aluminium alloys The photometric acid dehydration gravimetric mehtod for the determination of silicon content
Chinese Name: 铁铬铝合金化学分析方法 高氯酸脱水重量法测定硅量
Chinese Classification: K14    Electrician alloy parts
Professional Classification: JB    Professional Standard - Machinery
Source Content Issued by: State Bureau of Quality and Technical Supervision
Issued on: 1999-8-6
Implemented on: 2000-1-1
Status: valid
Superseding:ZB K 14003.4-1988 铁路铝合金化学分析方法 高氯酸脱水重量法测定硅量
Target Language: English
File Format: PDF
Word Count: 2000 words
Translation Price(USD): 164.0
Delivery: via email in 1 business day
1 Scope This standard specifies the photometric acid dehydration gravimetric method for the determination of silicon content in iron-chromium-aluminium alloys. This standard is applicable to the determination of silicon content in iron-chromium-aluminium alloys, and the determination range is from 0.10% to 1.00%. 2 Method Summary The test portion will be dissolved in acid, and will be heated with perchloric acid and smoke to dehydrate the silicic acid, the silicic acid will be filtered, washed and burnt into silicon dioxide. The silicon will be treated with sulfuric acid-hydrofluoric acid to become into silicon tetrafluoride, and the silicon tetrafluoride will evaporate to remove the silicon, hereby, the percentage content of silicon can be calculated according to the difference in mass before and after removing silicon.
Contents Foreword I 1 Scope 2 Method Summary 3 Reagents 4 Analytical Procedures 5 Calculation of Analysis Results 6 Permissible Deviation
Code of China
Standard
JB/T 9548.4-1999  Methods for chemical analysis of iron-chromium-aluminium alloys The photometric acid dehydration gravimetric mehtod for the determination of silicon content (English Version)
Standard No.JB/T 9548.4-1999
Statusvalid
LanguageEnglish
File FormatPDF
Word Count2000 words
Price(USD)164.0
Implemented on2000-1-1
Deliveryvia email in 1 business day
Detail of JB/T 9548.4-1999
Standard No.
JB/T 9548.4-1999
English Name
Methods for chemical analysis of iron-chromium-aluminium alloys The photometric acid dehydration gravimetric mehtod for the determination of silicon content
Chinese Name
铁铬铝合金化学分析方法 高氯酸脱水重量法测定硅量
Chinese Classification
K14
Professional Classification
JB
ICS Classification
Issued by
State Bureau of Quality and Technical Supervision
Issued on
1999-8-6
Implemented on
2000-1-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
ZB K 14003.4-1988 铁路铝合金化学分析方法 高氯酸脱水重量法测定硅量
Language
English
File Format
PDF
Word Count
2000 words
Price(USD)
164.0
Keywords
JB/T 9548.4-1999, JB 9548.4-1999, JBT 9548.4-1999, JB/T9548.4-1999, JB/T 9548.4, JB/T9548.4, JB9548.4-1999, JB 9548.4, JB9548.4, JBT9548.4-1999, JBT 9548.4, JBT9548.4
Introduction of JB/T 9548.4-1999
1 Scope This standard specifies the photometric acid dehydration gravimetric method for the determination of silicon content in iron-chromium-aluminium alloys. This standard is applicable to the determination of silicon content in iron-chromium-aluminium alloys, and the determination range is from 0.10% to 1.00%. 2 Method Summary The test portion will be dissolved in acid, and will be heated with perchloric acid and smoke to dehydrate the silicic acid, the silicic acid will be filtered, washed and burnt into silicon dioxide. The silicon will be treated with sulfuric acid-hydrofluoric acid to become into silicon tetrafluoride, and the silicon tetrafluoride will evaporate to remove the silicon, hereby, the percentage content of silicon can be calculated according to the difference in mass before and after removing silicon.
Contents of JB/T 9548.4-1999
Contents Foreword I 1 Scope 2 Method Summary 3 Reagents 4 Analytical Procedures 5 Calculation of Analysis Results 6 Permissible Deviation
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
JB/T 9548.4-1999, JB 9548.4-1999, JBT 9548.4-1999, JB/T9548.4-1999, JB/T 9548.4, JB/T9548.4, JB9548.4-1999, JB 9548.4, JB9548.4, JBT9548.4-1999, JBT 9548.4, JBT9548.4