2025-12-7 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/YY/T 1874-2023
YY/T 1874-2023   Active implantable medical devices―Electromagnetic compatibility―EMC test protocols for implantable cardiac pacemakers,implantable cardioverter defibrillators and cardiac resynchronization devices (English Version)
Standard No.: YY/T 1874-2023 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 56500 words Translation Price(USD):1695.0 remind me the price change

Email:

Implemented on:2024-5-1 Delivery: via email in 1~5 business day

→ → →

,,2024-5-1,27B19C9CC777B6C51679471401213
Standard No.: YY/T 1874-2023
English Name: Active implantable medical devices―Electromagnetic compatibility―EMC test protocols for implantable cardiac pacemakers,implantable cardioverter defibrillators and cardiac resynchronization devices
Chinese Name: 有源植入式医疗器械 电磁兼容 植入式心脏起搏器、植入式心律转复除颤器和心脏再同步器械的电磁兼容测试细则
Chinese Classification: C35    Orthopedic devices
Professional Classification: YY    Professional Standard - Pharmaceutics
ICS Classification: 11.040.40 11.040.40    Implants for surgery, prosthetics and orthotics 11.040.40
Source Content Issued by: National Medical Products Adminstration
Issued on: 2023-03-14
Implemented on: 2024-5-1
Status: valid
Target Language: English
File Format: PDF
Word Count: 56500 words
Translation Price(USD): 1695.0
Delivery: via email in 1~5 business day
本文件规定了用于评价可与经静脉电极导线系统一起提供一种或多种心动过缓、心动过速和心脏再同步等治疗的有源植入式心血管器械的电磁兼容(EMC)试验方法。
本文件规定了此类器械与可运行于下列两个EM频谱范围内的EM发射器发生相互作用时的性能界限:0 Hz ≤ f < 385 MHz;385 MHz ≤ f ≤ 3000 MHz。
本文件还规定了保护此类器械免受医疗环境EM场影响的要求,定义了所需的随附文件,并提供了关于EM发射器制造商与预期的抗扰度等级信息。
本文件适用于可与经静脉电极导线系统一起提供一种或多种心动过缓、心动过速和心脏再同步等治疗的有源植入式心血管器械。
Code of China
Standard
YY/T 1874-2023  Active implantable medical devices―Electromagnetic compatibility―EMC test protocols for implantable cardiac pacemakers,implantable cardioverter defibrillators and cardiac resynchronization devices (English Version)
Standard No.YY/T 1874-2023
Statusvalid
LanguageEnglish
File FormatPDF
Word Count56500 words
Price(USD)1695.0
Implemented on2024-5-1
Deliveryvia email in 1~5 business day
Detail of YY/T 1874-2023
Standard No.
YY/T 1874-2023
English Name
Active implantable medical devices―Electromagnetic compatibility―EMC test protocols for implantable cardiac pacemakers,implantable cardioverter defibrillators and cardiac resynchronization devices
Chinese Name
有源植入式医疗器械 电磁兼容 植入式心脏起搏器、植入式心律转复除颤器和心脏再同步器械的电磁兼容测试细则
Chinese Classification
C35
Professional Classification
YY
ICS Classification
Issued by
National Medical Products Adminstration
Issued on
2023-03-14
Implemented on
2024-5-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
56500 words
Price(USD)
1695.0
Keywords
YY/T 1874-2023, YY 1874-2023, YYT 1874-2023, YY/T1874-2023, YY/T 1874, YY/T1874, YY1874-2023, YY 1874, YY1874, YYT1874-2023, YYT 1874, YYT1874
Introduction of YY/T 1874-2023
本文件规定了用于评价可与经静脉电极导线系统一起提供一种或多种心动过缓、心动过速和心脏再同步等治疗的有源植入式心血管器械的电磁兼容(EMC)试验方法。
本文件规定了此类器械与可运行于下列两个EM频谱范围内的EM发射器发生相互作用时的性能界限:0 Hz ≤ f < 385 MHz;385 MHz ≤ f ≤ 3000 MHz。
本文件还规定了保护此类器械免受医疗环境EM场影响的要求,定义了所需的随附文件,并提供了关于EM发射器制造商与预期的抗扰度等级信息。
本文件适用于可与经静脉电极导线系统一起提供一种或多种心动过缓、心动过速和心脏再同步等治疗的有源植入式心血管器械。
Contents of YY/T 1874-2023
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
YY/T 1874-2023, YY 1874-2023, YYT 1874-2023, YY/T1874-2023, YY/T 1874, YY/T1874, YY1874-2023, YY 1874, YY1874, YYT1874-2023, YYT 1874, YYT1874