GB 1094.11-2007   Power transformers—Part 11:Dry-type transformers (English Version)
Standard No.: GB 1094.11-2007 Status:valid remind me the status change

Email:

Language:English File Format:PDF
Word Count: 12000 words Price(USD):300.0 remind me the price change

Email:

Implemented on:2008-4-1 Delivery: via email in 1 business day
,,
Standard No.: GB 1094.11-2007
English Name: Power transformers—Part 11:Dry-type transformers
Chinese Name: 电力变压器 第11部分:干式变压器
Chinese Classification: K41    Transformer
Professional Classification: GB    National Standard
Issued by: AQSIQ, SAC
Issued on: 2007-07-11
Implemented on: 2008-4-1
Status: valid
Superseded by:GB/T 1094.11-2022 Power transformers—Part 11: Dry-type transformers
强制性推荐性标准
其文本不做任何
Superseding:GB 6450-1986 Dry-type power transformers
Language: English
File Format: PDF
Word Count: 12000 words
Price(USD): 300.0
Delivery: via email in 1 business day
1 Scope This part of GB 1094 applies to dry-type power transformers (including auto-transformers) having values of highest voltage for equipment up to and including 40.5 kV and at least one winding operating at greater than 1.1 kV. The standard applies to all construction technologies. This standard does not apply to: ——gas-filled dry type transformers where the gas is not air; ——single-phase transformers rated at less than 5 kVA; ——poly-phase transformers rated at less than 15 kVA; ——instrument transformers; ——starting transformers; ——testing transformers; ——traction transformers mounted on rolling stock; ——flameproof and mining transformers; ——welding transformers; ——voltage regulating transformers; ——small power transformers in which safety is a special consideration. Where corresponding standards do not exist for the transformers mentioned above or for other special transformers, this part may be applicable as a whole or in parts. 2 Normative References The following standards contain provisions which, through reference in this part of GB 1094, constitute provisions of this part. For dated references, subsequent amendments to (excluding corrections to), or revisions of, any of these publications do not apply. However, parties to agreements based on this part are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below. For undated references, the latest edition of the referenced document applies. GB 311.1 Insulation Co-ordination for High Voltage Transmission and Distribution Equipment (GB 311.1-1997, neq IEC 60071-1:1993) GB 1094.1 Power Transformers—Part 1: General (GB 1094.1-1996, eqv IEC 60076-1:1993) GB 1094.2 Power Transformers—Part 2: Temperature Rise (GB 1094.2-1996, eqv IEC 60076-2:1993) GB 1094.3 Power Transformers—Part 3: Insulation Levels, Dielectric Tests and External Clearances in Air (GB 1094.3-2003, IEC 60076-3:2000, MOD) GB 1094.5 Power Transformers—Part 5: Ability to Withstand Short Circuit (GB 1094.5-2003, IEC 60076-5:2000, MOD) GB/T 1094.10 Power Transformers—Part 10: Determination of Sound Levels (GB/T 1094.10-2003, IEC 60076-10:2001, MOD) GB/T 2900.15 Electrotechnical Terminology—Transformer, Instrument Transformer, Voltage Regulator and Reactor (GB/T 2900.15-1997, neq IEC 60050-421:1990, IEC 60050-321:1986) GB 4208 Degrees of Protection Provided by Enclosures (IP Code) (GB 4208-1993, eqv IEC 60529:1989) GB/T 7354 Partial Discharge Measurements (GB/T 7354-2003, IEC 60270:2000, IDT) GB/T 11021 Thermal Evaluation and Classification of Electrical Insulation (GB/T 11021-1989, eqv IEC 60085:1984) GB/T 17211-1998 Loading Guide for Dry-type Power Transformers (eqv IEC 60905:1987) GB/T 17467 High-voltage/Low-voltage Prefabricated Substation (GB/T 17467-1998, eqv IEC 61330:1995) GB/T 18380.3 Tests on Electric Cables under Fire Conditions—Part 3: Tests on Bunched Wires or Cables (GB/T 18380.3-2001, idt IEC 60332-3:1992) 3 Terms and Definitions For the purposes of this part, the terms and definitions given in GB/T 2900.15 and the followings apply. 3.1 dry-type transformer transformer of which the iron core and windings are not immersed in an insulating liquid 3.2 totally enclosed dry-type transformer transformer in an un-pressurized enclosure cooled by the circulation of the internal air 3.3 enclosed dry-type transformer transformer in a ventilated enclosure cooled by the circulation of the external air 3.4 non-enclosed dry-type transformer transformer supplied without a protective enclosure cooled by natural or forced air ventilation
Foreword i 1 Scope 2 Normative References 3 Terms and Definitions 4 Service Conditions 4.1 General 4.2 Normal Service Conditions 4.3 Electromagnetic Compatibility (EMC) 4.4 Provision for Unusual Service Conditions 4.5 Transport and Storage Conditions 5 Tappings 6 Connections 7 Ability to Withstand Short Circuit 8 Rating 8.1 General 8.2 Rated Power 8.3 Preferred Values of Rated Power 8.4 Operation at Higher Than Rated Voltage 8.5 Operation with Fan Cooling 8.6 Operation in an Enclosure 9 Rating Plate 9.1 Rating Plate Fitted to the Transformer 9.2 Rating Plate Fitted to the Transformer Enclosure 10 Identification according to Cooling Method 10.1 Identification Symbols 10.2 Arrangement of Symbols 11 Temperature-rise Limits 11.1 Normal Temperature-rise Limits 11.2 Reduced Temperature Rises for Transformers Designed for High Cooling Air Temperatures or Special Air Cooling Conditions 11.3 High Altitude Temperature Rise Correction 12 Insulation Levels 12.1 General 12.2 Transformers for Use at High Altitudes 13 Climatic, Environmental and Fire Behaviour Classes 13.1 Climatic Classes 13.2 Environmental Classes 13.3 Fire Behaviour Classes 13.4 Test Criteria for Climatic, Environmental and Fire Behaviour Classes 14 General Requirements for Tests 15 Measurement of Winding Resistance (Routine Test) 16 Measurement of Voltage Ratio and Check of Phase Displacement (Routine Test) 17 Measurement of Short-Circuit Impedance and Load Loss (Routine Test) 18 Measurement of No-load Loss and Current (Routine Test) 19 Separate-Source AC Withstand Voltage Test (Routine Test) 20 Induced AC Withstand Voltage Test (Routine Test) 21 Lightning Impulse Test (Type Test) 22 Partial Discharge Measurement (Routine and Special Test) 22.1 General 22.2 Basic Measuring Circuit (Typical Only) 22.3 Calibration of the Measuring Circuit 22.4 Voltage Application 22.5 Partial Discharge Acceptance Levels 23 Temperature-Rise Test (Type Test) 23.1 General 23.2 Methods of Loading 23.3 Winding Temperature-Rise Correction for Reduced Current 23.4 Determination of Steady State Conditions 24 Measurement of Sound Level (Special Test) 25 Short-Circuit Test (Special Test) 26 Environmental Test (Special Test) 26.1 General 26.2 Validity of the Test 26.3 Testing Procedure 27 Climatic Test (Special Test) 27.1 General 27.2 Validity of the Test 27.3 Climatic test (Thermal Shock Test) for C1 Class Transformers 27.4 Climatic Test (Thermal Shock Test) for C2 Class Transformers 28 Fire Behaviour Test (Special Test) 28.1 General 28.2 Checking of Corrosive and Harmful Gases Emission 28.3 Fire Behaviour Test for F1 Class Transformer 28.4 Quantities to be Measured and Measuring Devices 28.5 Calibration of the Test Chamber without Test Object 28.6 Test Method 28.7 Test Report 28.8 Criteria for Evaluating the Test Results 29 Tolerances 30 Protection against Direct Contact 31 Degrees of Protection Provided by Enclosures 32 Earthing Terminal 33 Information Required with Enquiry and Order 34 Information Concerning Installation and Safety Annex A (Informative) Corresponding Numbering Equivalent Clauses and Tables between this Part and IEC 60076-11:2004 Annex B (Informative) Technical differences and their Causes between this Part and IEC 60076-11:2004 Annex C (Informative) Insulation Levels Based on North American Practice in IEC 60076-11:2004 Annex D (Informative) Installation and Safety of Dry-Type Transformers
Referred in GB 1094.11-2007:
*GB 311.1-2012 Insulation co-ordination - Part 1:Definitions, principles and rules
*GB 1094.1-2013 Power transformers--Part 1: General
*GB 1094.2-2013 Power transformers - Part 2: Temperature rise for liquid-immersed transformers
*GB 1094.3-2003 Power transformers?Part 3:Insulation levels,dielectric tests and external clearances in air
*GB 1094.5-2008 Power transformers - Part 5: Ability to withstand short circuit
*GB/T 1094.10-2003 Power transformers - Part 10: Determination of sound
*GB/T 2900.15-1997 Electrotechnical terminology--Transformer,instrument transformer,voltage regulator and reactor
*GB 4208-2008 Degrees of Protection Provided By Enclosure (IP Code)
*GB/T 7354-2018
*GB/T 11021-2014 Electrical Insulation -Thermal Evaluation and Designation
*GB/T 17211-1998 Loading guide for dry-type power transformers
*GB/T 17467-2010 High-voltage/low-voltage prefabricated substation
*GB/T 18380.3-2001 Tests on electric cables under fire conditions-Part 3:Tests on bunched wires or cables
GB 1094.11-2007 is referred in:
* GB 1094.1-2013 Power transformers--Part 1: General
* GB 1094.1-2013 Power transformers--Part 1: General
* GB 1094.1-2013 Power transformers--Part 1: General
* GB 1094.1-2013 Power transformers--Part 1: General
* GB 1094.1-2013 Power transformers--Part 1: General
* GB 17467-2010 High-voltage/low-voltage prefabricated substation
* GB 1094.5-2008 Power transformers - Part 5: Ability to withstand short circuit
* GB/T 10230.2-2007 Tap-changers—Part 2:Application guide
* GB/T 17468-2008 The Guide for Choice Power Transformers
* DL/T 572-2010 Operation specification for power transformer
* GB 20052-2013 Minimum allowable values of energy efficiency and energy efficiency grades for three-phase distribution transformers
* GB/T 230.2-2012 Metallic materials—Rockwell hardness test—Part 2:Verification and calibration of testing machines
*JB/T 8749.1-2007 Voltage regulators-Part1:General requirements and tests
*GB/T 1094.1-2013/XG1-2018 Power transformers―Part 1:General, inluding Amendment 1
*GB/T 18494.1-2014 Converter transformers―Part 1:Transformers for industrial applications
*GB/T 1094.12-2013 Power transformers―Part 12: Loading guide for dry-type power transformers
Code of China
Standard
GB 1094.11-2007  Power transformers—Part 11:Dry-type transformers (English Version)
Standard No.GB 1094.11-2007
Statusvalid
LanguageEnglish
File FormatPDF
Word Count12000 words
Price(USD)300.0
Implemented on2008-4-1
Deliveryvia email in 1 business day
Detail of GB 1094.11-2007
Standard No.
GB 1094.11-2007
English Name
Power transformers—Part 11:Dry-type transformers
Chinese Name
电力变压器 第11部分:干式变压器
Chinese Classification
K41
Professional Classification
GB
ICS Classification
Issued by
AQSIQ, SAC
Issued on
2007-07-11
Implemented on
2008-4-1
Status
valid
Superseded by
GB/T 1094.11-2022 Power transformers—Part 11: Dry-type transformers
强制性推荐性标准
其文本不做任何
Superseded on
Abolished on
Superseding
GB 6450-1986 Dry-type power transformers
Language
English
File Format
PDF
Word Count
12000 words
Price(USD)
300.0
Keywords
GB 1094.11-2007, GB/T 1094.11-2007, GBT 1094.11-2007, GB1094.11-2007, GB 1094.11, GB1094.11, GB/T1094.11-2007, GB/T 1094.11, GB/T1094.11, GBT1094.11-2007, GBT 1094.11, GBT1094.11
Introduction of GB 1094.11-2007
1 Scope This part of GB 1094 applies to dry-type power transformers (including auto-transformers) having values of highest voltage for equipment up to and including 40.5 kV and at least one winding operating at greater than 1.1 kV. The standard applies to all construction technologies. This standard does not apply to: ——gas-filled dry type transformers where the gas is not air; ——single-phase transformers rated at less than 5 kVA; ——poly-phase transformers rated at less than 15 kVA; ——instrument transformers; ——starting transformers; ——testing transformers; ——traction transformers mounted on rolling stock; ——flameproof and mining transformers; ——welding transformers; ——voltage regulating transformers; ——small power transformers in which safety is a special consideration. Where corresponding standards do not exist for the transformers mentioned above or for other special transformers, this part may be applicable as a whole or in parts. 2 Normative References The following standards contain provisions which, through reference in this part of GB 1094, constitute provisions of this part. For dated references, subsequent amendments to (excluding corrections to), or revisions of, any of these publications do not apply. However, parties to agreements based on this part are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below. For undated references, the latest edition of the referenced document applies. GB 311.1 Insulation Co-ordination for High Voltage Transmission and Distribution Equipment (GB 311.1-1997, neq IEC 60071-1:1993) GB 1094.1 Power Transformers—Part 1: General (GB 1094.1-1996, eqv IEC 60076-1:1993) GB 1094.2 Power Transformers—Part 2: Temperature Rise (GB 1094.2-1996, eqv IEC 60076-2:1993) GB 1094.3 Power Transformers—Part 3: Insulation Levels, Dielectric Tests and External Clearances in Air (GB 1094.3-2003, IEC 60076-3:2000, MOD) GB 1094.5 Power Transformers—Part 5: Ability to Withstand Short Circuit (GB 1094.5-2003, IEC 60076-5:2000, MOD) GB/T 1094.10 Power Transformers—Part 10: Determination of Sound Levels (GB/T 1094.10-2003, IEC 60076-10:2001, MOD) GB/T 2900.15 Electrotechnical Terminology—Transformer, Instrument Transformer, Voltage Regulator and Reactor (GB/T 2900.15-1997, neq IEC 60050-421:1990, IEC 60050-321:1986) GB 4208 Degrees of Protection Provided by Enclosures (IP Code) (GB 4208-1993, eqv IEC 60529:1989) GB/T 7354 Partial Discharge Measurements (GB/T 7354-2003, IEC 60270:2000, IDT) GB/T 11021 Thermal Evaluation and Classification of Electrical Insulation (GB/T 11021-1989, eqv IEC 60085:1984) GB/T 17211-1998 Loading Guide for Dry-type Power Transformers (eqv IEC 60905:1987) GB/T 17467 High-voltage/Low-voltage Prefabricated Substation (GB/T 17467-1998, eqv IEC 61330:1995) GB/T 18380.3 Tests on Electric Cables under Fire Conditions—Part 3: Tests on Bunched Wires or Cables (GB/T 18380.3-2001, idt IEC 60332-3:1992) 3 Terms and Definitions For the purposes of this part, the terms and definitions given in GB/T 2900.15 and the followings apply. 3.1 dry-type transformer transformer of which the iron core and windings are not immersed in an insulating liquid 3.2 totally enclosed dry-type transformer transformer in an un-pressurized enclosure cooled by the circulation of the internal air 3.3 enclosed dry-type transformer transformer in a ventilated enclosure cooled by the circulation of the external air 3.4 non-enclosed dry-type transformer transformer supplied without a protective enclosure cooled by natural or forced air ventilation
Contents of GB 1094.11-2007
Foreword i 1 Scope 2 Normative References 3 Terms and Definitions 4 Service Conditions 4.1 General 4.2 Normal Service Conditions 4.3 Electromagnetic Compatibility (EMC) 4.4 Provision for Unusual Service Conditions 4.5 Transport and Storage Conditions 5 Tappings 6 Connections 7 Ability to Withstand Short Circuit 8 Rating 8.1 General 8.2 Rated Power 8.3 Preferred Values of Rated Power 8.4 Operation at Higher Than Rated Voltage 8.5 Operation with Fan Cooling 8.6 Operation in an Enclosure 9 Rating Plate 9.1 Rating Plate Fitted to the Transformer 9.2 Rating Plate Fitted to the Transformer Enclosure 10 Identification according to Cooling Method 10.1 Identification Symbols 10.2 Arrangement of Symbols 11 Temperature-rise Limits 11.1 Normal Temperature-rise Limits 11.2 Reduced Temperature Rises for Transformers Designed for High Cooling Air Temperatures or Special Air Cooling Conditions 11.3 High Altitude Temperature Rise Correction 12 Insulation Levels 12.1 General 12.2 Transformers for Use at High Altitudes 13 Climatic, Environmental and Fire Behaviour Classes 13.1 Climatic Classes 13.2 Environmental Classes 13.3 Fire Behaviour Classes 13.4 Test Criteria for Climatic, Environmental and Fire Behaviour Classes 14 General Requirements for Tests 15 Measurement of Winding Resistance (Routine Test) 16 Measurement of Voltage Ratio and Check of Phase Displacement (Routine Test) 17 Measurement of Short-Circuit Impedance and Load Loss (Routine Test) 18 Measurement of No-load Loss and Current (Routine Test) 19 Separate-Source AC Withstand Voltage Test (Routine Test) 20 Induced AC Withstand Voltage Test (Routine Test) 21 Lightning Impulse Test (Type Test) 22 Partial Discharge Measurement (Routine and Special Test) 22.1 General 22.2 Basic Measuring Circuit (Typical Only) 22.3 Calibration of the Measuring Circuit 22.4 Voltage Application 22.5 Partial Discharge Acceptance Levels 23 Temperature-Rise Test (Type Test) 23.1 General 23.2 Methods of Loading 23.3 Winding Temperature-Rise Correction for Reduced Current 23.4 Determination of Steady State Conditions 24 Measurement of Sound Level (Special Test) 25 Short-Circuit Test (Special Test) 26 Environmental Test (Special Test) 26.1 General 26.2 Validity of the Test 26.3 Testing Procedure 27 Climatic Test (Special Test) 27.1 General 27.2 Validity of the Test 27.3 Climatic test (Thermal Shock Test) for C1 Class Transformers 27.4 Climatic Test (Thermal Shock Test) for C2 Class Transformers 28 Fire Behaviour Test (Special Test) 28.1 General 28.2 Checking of Corrosive and Harmful Gases Emission 28.3 Fire Behaviour Test for F1 Class Transformer 28.4 Quantities to be Measured and Measuring Devices 28.5 Calibration of the Test Chamber without Test Object 28.6 Test Method 28.7 Test Report 28.8 Criteria for Evaluating the Test Results 29 Tolerances 30 Protection against Direct Contact 31 Degrees of Protection Provided by Enclosures 32 Earthing Terminal 33 Information Required with Enquiry and Order 34 Information Concerning Installation and Safety Annex A (Informative) Corresponding Numbering Equivalent Clauses and Tables between this Part and IEC 60076-11:2004 Annex B (Informative) Technical differences and their Causes between this Part and IEC 60076-11:2004 Annex C (Informative) Insulation Levels Based on North American Practice in IEC 60076-11:2004 Annex D (Informative) Installation and Safety of Dry-Type Transformers
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Foryou Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 1094.11-2007, GB/T 1094.11-2007, GBT 1094.11-2007, GB1094.11-2007, GB 1094.11, GB1094.11, GB/T1094.11-2007, GB/T 1094.11, GB/T1094.11, GBT1094.11-2007, GBT 1094.11, GBT1094.11