GB 16895.3-2004 Electrical installations of buildings—Part 5-54:Selection and erection of electrical equipment—Earthing arrangements,protective conductors and protective bonding conductors (English Version)
Electrical installations of buildings—Part 5-54:Selection and erection of electrical equipment—Earthing arrangements,protective conductors and protective bonding conductors
This Part of series standard "Electrical Installations of Buildings" addresses the earthing arrangements, protective conductors and protective bonding conductors in order to satisfy the safety of the electrical installation.
Foreword III
541 General
541.1 Scope
541.2 Normative references
541.3 Definitions
542 Earthing arrangements
542.1 General requirements
542.2 Earth electrodes
542.3 Earthing conductors
542.4 Main earthing terminal
543 Protective conductors
543.1 Minimum cross-sectional areas
543.2 Types of protective conductors
543.3 Electrical continuity of protective conductors
543.4 PEN conductors
543.5 Combined protective and functional earthing
543.6 Arrangement of protective conductors
543.7 Reinforced protective conductors for protective conductor currents exceeding 10 mA
544 Protective bonding conductors (equipotential bonding conductors)
544.1 Protective bonding conductors for the connection to the main earthing terminal
544.2 Protective bonding conductors for supplementary bonding
Appendix A (Normative) Method for Deriving the Factor k in 543.1.2 (see also IEC 60724 and IEC 60949)
Appendix B (Informative) Illustration of Earthing Arrangements, Protective Conductors and Protective Bonding Conductors
Table 54.1 Common Minimum Sizes for Earth Electrodes of Commonly Used Material from the Point of View of Corrosion and Mechanical Strength where Embedded in the Soil
Table 54.2 Minimum Cross-sectional areas of Earthing Conductors Buried in the Soil
Table 54.3 Minimum Cross-sectional Area of Protective Conductors
Table A.54.1 Value of Parameters for Different Materials
Table A.54.2 Values of k for Insulated Protective Conductors not Incorporated in Cables and not Bunched with other Cables
Table A.54.3 Values of k for Bare Protective Conductors in Contact with Cable Covering but not Bunched with other Cables
Table A.54.4 Values of k for Protective Conductors as a Core Incorporated in a Cable or Bunched with other Cables or Insulated Conductors
Table A.54.5 Values of k for Protective Conductors as a Metallic Layer of a Cable e.g. Armour, Metallic Sheath, Concentric Conductor, etc.
Table A.54.6 Value of k for Bare Conductors where there is no Risk of Damage to any Neighbouring Material by the Temperature Indicated
Bibliography
GB 16895.3-2004 Electrical installations of buildings—Part 5-54:Selection and erection of electrical equipment—Earthing arrangements,protective conductors and protective bonding conductors (English Version)
Standard No.
GB 16895.3-2004
Status
valid
Language
English
File Format
PDF
Word Count
6000 words
Price(USD)
150.0
Implemented on
2005-2-1
Delivery
via email in 1 business day
Detail of GB 16895.3-2004
Standard No.
GB 16895.3-2004
English Name
Electrical installations of buildings—Part 5-54:Selection and erection of electrical equipment—Earthing arrangements,protective conductors and protective bonding conductors
This Part of series standard "Electrical Installations of Buildings" addresses the earthing arrangements, protective conductors and protective bonding conductors in order to satisfy the safety of the electrical installation.
Contents of GB 16895.3-2004
Foreword III
541 General
541.1 Scope
541.2 Normative references
541.3 Definitions
542 Earthing arrangements
542.1 General requirements
542.2 Earth electrodes
542.3 Earthing conductors
542.4 Main earthing terminal
543 Protective conductors
543.1 Minimum cross-sectional areas
543.2 Types of protective conductors
543.3 Electrical continuity of protective conductors
543.4 PEN conductors
543.5 Combined protective and functional earthing
543.6 Arrangement of protective conductors
543.7 Reinforced protective conductors for protective conductor currents exceeding 10 mA
544 Protective bonding conductors (equipotential bonding conductors)
544.1 Protective bonding conductors for the connection to the main earthing terminal
544.2 Protective bonding conductors for supplementary bonding
Appendix A (Normative) Method for Deriving the Factor k in 543.1.2 (see also IEC 60724 and IEC 60949)
Appendix B (Informative) Illustration of Earthing Arrangements, Protective Conductors and Protective Bonding Conductors
Table 54.1 Common Minimum Sizes for Earth Electrodes of Commonly Used Material from the Point of View of Corrosion and Mechanical Strength where Embedded in the Soil
Table 54.2 Minimum Cross-sectional areas of Earthing Conductors Buried in the Soil
Table 54.3 Minimum Cross-sectional Area of Protective Conductors
Table A.54.1 Value of Parameters for Different Materials
Table A.54.2 Values of k for Insulated Protective Conductors not Incorporated in Cables and not Bunched with other Cables
Table A.54.3 Values of k for Bare Protective Conductors in Contact with Cable Covering but not Bunched with other Cables
Table A.54.4 Values of k for Protective Conductors as a Core Incorporated in a Cable or Bunched with other Cables or Insulated Conductors
Table A.54.5 Values of k for Protective Conductors as a Metallic Layer of a Cable e.g. Armour, Metallic Sheath, Concentric Conductor, etc.
Table A.54.6 Value of k for Bare Conductors where there is no Risk of Damage to any Neighbouring Material by the Temperature Indicated
Bibliography