Ultraviolet germicidal lamp
1 Scope
This standard specifies the product classification, technical requirements, test methods, inspection rules, marking, packaging, transportation and storage of low-pressure mercury vapor discharge ultraviolet germicidal lamps (hereinafter referred to as "lamps").
This standard is applicable to double-capped, single-capped or self-ballasted ultraviolet germicidal lamps with or without ozone and with a peak wavelength of ultraviolet radiation of 253.7nm, which are made of quartz glass.
This standard is applicable to lamps having a power below 65W.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
GB/T 1406.1 Types and dimensions of lamp caps - Part 1: Screw caps (IEC 60061-1: 2005, MOD)
GB/T 1406.2 Types and dimensions of lamp caps - Part 2: Pin lamp caps (IEC 60061-1: 2005, MOD)
GB/T 1406.5 Types and dimensions of lamp caps - Part 5: Bayonet caps (IEC 60061-1: 2005, MOD)
GB/T 2828.1 Sampling procedures for inspection by attributes - Part 1: Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot inspection (ISO 2859-1: 1999, IDT)
GB/T 2829 Sampling procedures and tables for periodic inspection by attributes (apply to inspection of process stability)
GB/T 10682 Double-capped fluorescent lamps - Performance specifications
GB 16843 Single-capped fluorescent lamps - Safety specifications (IEC 1199: 1993, IDT)
GB 16844 Self-ballasted lamps for general lighting services - Safety requirements (IEC 60968: 1988, IDT)
GB/T 17262 Single-capped fluorescent lamps - Performance specification
GB/T 17263 Self-ballasted lamps for general lighting service - Performance requirements
GB 18774 Double-capped fluorescent lamps - Safety specifications (IEC 61195: 1999, IDT)
HJ/T 47-1999 Technical conditions of sampler for stack gas
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1
ultraviolet germicidal lamp
low-pressure mercury vapor discharge lamp made of quartz glass or other vitaglass, which discharges ultraviolet radiation with a wavelength of 253.7nm for killing bacteria and viruses
3.2
ozone output efficacy
ratio of ozone produced per unit time to the power consumed by the lamp when the lamp is lighted up under specified conditions, in g/(kW·h)
3.3
nominal value
value indicated on the lamp
3.4
rated value
specific value of lamp under specified working conditions, with such value and conditions specified in this standard or by the manufacturer or the seller
3.5
initial readings
startup characteristics of the lamp measured before aging and the ultraviolet radiation light, electrical characteristics and ozone characteristics measured after aging for 100h
Foreword i
1 Scope
2 Normative references
3 Terms and definitions
4 Product classification
5 Technical requirements
6 Test methods
7 Inspection rules
8 Marking, packaging, transportation and storage
Annex A (Normative) Measurement method for ultraviolet radiation luminance
Annex B (Normative) Test method for ultraviolet radiation flux and electrical parameters
Annex C (Normative) Life test method
Annex D (Normative) Test method for ozone output efficacy
Ultraviolet germicidal lamp
1 Scope
This standard specifies the product classification, technical requirements, test methods, inspection rules, marking, packaging, transportation and storage of low-pressure mercury vapor discharge ultraviolet germicidal lamps (hereinafter referred to as "lamps").
This standard is applicable to double-capped, single-capped or self-ballasted ultraviolet germicidal lamps with or without ozone and with a peak wavelength of ultraviolet radiation of 253.7nm, which are made of quartz glass.
This standard is applicable to lamps having a power below 65W.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
GB/T 1406.1 Types and dimensions of lamp caps - Part 1: Screw caps (IEC 60061-1: 2005, MOD)
GB/T 1406.2 Types and dimensions of lamp caps - Part 2: Pin lamp caps (IEC 60061-1: 2005, MOD)
GB/T 1406.5 Types and dimensions of lamp caps - Part 5: Bayonet caps (IEC 60061-1: 2005, MOD)
GB/T 2828.1 Sampling procedures for inspection by attributes - Part 1: Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot inspection (ISO 2859-1: 1999, IDT)
GB/T 2829 Sampling procedures and tables for periodic inspection by attributes (apply to inspection of process stability)
GB/T 10682 Double-capped fluorescent lamps - Performance specifications
GB 16843 Single-capped fluorescent lamps - Safety specifications (IEC 1199: 1993, IDT)
GB 16844 Self-ballasted lamps for general lighting services - Safety requirements (IEC 60968: 1988, IDT)
GB/T 17262 Single-capped fluorescent lamps - Performance specification
GB/T 17263 Self-ballasted lamps for general lighting service - Performance requirements
GB 18774 Double-capped fluorescent lamps - Safety specifications (IEC 61195: 1999, IDT)
HJ/T 47-1999 Technical conditions of sampler for stack gas
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1
ultraviolet germicidal lamp
low-pressure mercury vapor discharge lamp made of quartz glass or other vitaglass, which discharges ultraviolet radiation with a wavelength of 253.7nm for killing bacteria and viruses
3.2
ozone output efficacy
ratio of ozone produced per unit time to the power consumed by the lamp when the lamp is lighted up under specified conditions, in g/(kW·h)
3.3
nominal value
value indicated on the lamp
3.4
rated value
specific value of lamp under specified working conditions, with such value and conditions specified in this standard or by the manufacturer or the seller
3.5
initial readings
startup characteristics of the lamp measured before aging and the ultraviolet radiation light, electrical characteristics and ozone characteristics measured after aging for 100h
Contents of GB 19258-2012
Foreword i
1 Scope
2 Normative references
3 Terms and definitions
4 Product classification
5 Technical requirements
6 Test methods
7 Inspection rules
8 Marking, packaging, transportation and storage
Annex A (Normative) Measurement method for ultraviolet radiation luminance
Annex B (Normative) Test method for ultraviolet radiation flux and electrical parameters
Annex C (Normative) Life test method
Annex D (Normative) Test method for ozone output efficacy