2026-11-29 216.73.216.53
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB 2099.7-2024
GB 2099.7-2024   Cord extension socket-outlets for household and similar purposes―Safety technical specification (English)
This English text of GB 2099.7-2024 is translated by certified human translators, with proven quality
Standard No.: GB 2099.7-2024 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 21000 words Translation Price(USD):630.0 remind me the price change

Email:

Implementation Date:2025-8-1 Delivery: via email in 1 business day

→ → →

,,2025-8-1,DFA8CF413A41A1B41722219804735
Standard No.: GB 2099.7-2024
English Name: Cord extension socket-outlets for household and similar purposes―Safety technical specification
Chinese Name: 家用和类似用途延长线插座 安全技术规范
Chinese Classification: K30    Low voltage apparatus in general
Professional Classification: GB    National Standard
ICS Classification: 29.120.30 29.120.30    Plugs, socket -outlets, couplers 29.120.30
Source Content Issued by: SAMR; SAC
Issurane Date: 2024-07-24
Implementation Date: 2025-8-1
Status: valid
Replacing:GB/T 2099.7-2015 Plugs and socket-outlets for household and similar purposes―Part 2-7:Particular requirements for cord extension sets
Target Language: English
File Format: PDF
Word Count: 21000 words
Translation Price(USD): 630.0
Delivery: via email in 1 business day
GB 2099.7-2024 Cord extension socket-outlets for household and similar purposes — Safety technical specification 1 Scope This document specifies the classification, main technical parameters, requirements, signs, symbols and instructions, and inspection rules for cord extension socket-outlets, and describes the corresponding test methods. This document is applicable to cord extension socket-outlets for household and similar purposes, either indoors or outdoors. This document is also applicable to portable socket-outlets intended to be connected to one flexible cable. 2 Normative references The contents in the following documents constitute essential provisions of this document through normative references in the text. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB 1002—2024 Single phase plugs and socket-outlets for household and similar purposes — Types, basic parameters and dimensions GB/T 2099.1—2021 Plugs and socket-outlets for household and similar purposes — Part 1: General requirements GB/T 2099.6 Plugs and socket-outlets for household and similar purposes — Part 2: Particular requirements for fused plugs GB/T 2423.1 Environmental testing for electric and electronic products — Part 2: Test methods — Tests A: Cold GB/T 2423.2 Environmental testing for electric and electronic products — Part 2: Test methods — Tests B: Dry heat GB/T 2423.55 Environmental testing — Part 2: Test methods — Test Eh: Hammer tests GB/T 5013 (all parts) Rubber insulated cables of rated voltages up to and including 450/750 V GB/T 5023 (all parts) Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V GB/T 5169.5—2020 Fire hazard testing for electric and electronic products — Part 5: Test flames — Needle-flame test method — Apparatus, confirmatory test arrangement and guidance GB/T 5465.2 Graphical symbols for use on electrical equipment — Part 2: Graphical symbols GB/T 13539 (all parts) Low-voltage fuses GB/T 14536 (all parts) Automatic electrical controls GB/T 16842—2016 Protection of persons and equipment by enclosures — Probe for verification GB/T 17701 Circuit-breakers for equipment (CBE) GB/T 17465.1—2022 Appliance couplers for household and similar general purposes — Part 1: General requirements GB/T 17465.6—2022 Appliance couplers for household and similar general purposes — Part 3: Standard sheets and gauges GB/T 17799.1 Electromagnetic compatibility — Generic standards — Immunity for residential, commercial and light-industrial environments GB 17799.3 Electromagnetic compatibility (EMC) — Generic standards — Part 3: Emission standard for equipment in residential environments GB/T 19637—2017 Electrical accessories — Cable reels for household and similar purposes GB/T 20002.4 Drafting for special aspects in standards — Part 4: Safety aspects for their inclusion in standards GB/T 20234.1—2023 Connection set for conductive charging of electric vehicles — Part 1: General requirements GB/T 28046.3—2011 Road vehicles — Environmental conditions and testing for electrical and electronic equipment — Part 3: Mechanical loads GB/T 33594 Charging cables for electric vehicles 3 Terms and definitions For the purposes of this document, the terms and definitions given in GB/T 2099.1—2021 and listed in the following apply. 3.1 portable socket-outlet socket-outlet intended to be connected to one flexible cable and which can easily be moved from one place to another while connected to the supply [SOURCE: GB/T 2099.1—2021, 3.4, modified] 3.2 cord extension socket-outlet assembly consisting of one portable socket-outlet and one flexible cable fitted with or without one plug 3.3 maximum operating current current that the electrical accessory can withstand and is permitted to occur only for a short duration without compromising the safety of the accessory Note 1 to entry: It shall not persist for a long period, otherwise it will cause damage to the electrical accessory. 3.4 rated power power specified by the manufacturer for the cord extension socket-outlet 3.5 appliance inlet part of the appliance coupler integrated as a part of an appliance or incorporated as a separate part in the appliance or equipment or intended to be fixed to it [SOURCE: GB/T 17465.1—2022, 3.1.2] 3.6 cord extension socket-outlet with cable reel cord extension socket-outlet provided with a device for winding the flexible cable for use, in which the surface diameter of the wound flexible cable is greater than 4 times and less than 8 times the maximum diameter of a circular flexible cable, or greater than 4 times and less than 8 times the average of the maximum and minimum dimensions of a flat flexible cable 4 Classification and main technical parameters 4.1 Classification 4.1.1 Classification by product application: —ordinary cord extension socket-outlets; —cord extension socket-outlets for charging electric bicycles; —cord extension socket-outlets supplied from electric vehicle discharge systems; —cord extension socket-outlets mounted on furniture or desktops; —cord extension socket-outlets for other applications. 4.1.2 Classification by earthing provision: —cord extension socket-outlets without earthing contacts; —cord extension socket-outlets with earthing contacts. 4.1.3 Classification by method of cable connection: —rewirable cord extension socket-outlets; —non-rewirable cord extension socket-outlets; —cord extension socket-outlets with coupler-type inlets. 4.2 Main technical parameters and ratings 4.2.1 Rated voltage The preferred value of the rated voltage is 250 V. The rated voltages of the plug and socket-outlet of an ordinary cord extension socket-outlet shall be the same. The rated voltage of the cable shall not be less than that of the plug and socket-outlet. 4.2.2 Rated current 4.2.2.1 The rated current of the plug of an ordinary cord extension socket-outlet shall not be less than that of a single socket-outlet position. For an ordinary cord extension socket-outlet with overload protection, such as a fused plug or an overcurrent protective device, the rated current of the plug shall not be less than that of the fuse or overcurrent protective device. For an ordinary cord extension socket-outlet with multiple portable socket-outlets and without an overcurrent protective device, the rated current of the plug shall be at least the smaller of the following two current values: —the arithmetic sum of the maximum currents of all plugs that can be inserted into the ordinary cord extension socket-outlet; —the rated current of the relevant socket-outlet of the fixed wiring to which the plug is intended to be connected. 4.2.2.2 The rated current of a portable socket-outlet intended to be connected to one flexible cable shall not exceed 16 A. 4.2.3 Maximum operating current of cord extension socket-outlets The maximum operating current of a cord extension socket-outlet shall be the current that can be withstood for a short duration without causing damage to the electrical accessories. The maximum operating current may be taken as the lowest among the following current values: —the rated current of the plug; —the arithmetic sum of the maximum currents of all plugs that can be inserted into the cord extension socket-outlet; —the rated current of the overcurrent protective device with the minimum rated current. 4.2.4 Rated power/maximum allowable power The rated power/maximum allowable power of the socket-outlet shall be calculated by multiplying the rated current/maximum operating current of the product by the rated voltage, with a power factor of 1. 5 Requirements 5.1 Ordinary cord extension socket-outlets 5.1.1 General requirements
Contents Foreword II Introduction V 1 Scope 2 Normative references 3 Terms and definitions 4 Classification and main technical parameters 5 Requirements 6 Test methods 7 Signs, symbols and instructions 8 Inspection rules 9 Implementation of this standard Annex A (normative) Needle-flame test Annex B (normative) Safety-related routine tests for factory-wired portable socket-outlets (protection against electric shock and correct polarity) Bibliography Table 1 — Types and lengths of flexible cables and nominal cross-sectional area of conductors for cord extension socket-outlets Table 2 — Minimum overall retention force of the socket contacts of cord extension socket-outlets for charging electric bicycles Table 3 — Flexible cable length and nominal cross-sectional area of conductors of cord extension socket-outlets supplied from electric vehicle discharge systems Table 4 — Minimum overall retention force of the socket contacts of cord extension socket-outlets supplied from electric vehicle discharge systems Table B.1 — Diagrammatic representation of routine tests to be performed on portable electrical accessories with conductors as delivered
Referred in GB 2099.7-2024:
*GB 1002-2024 Single phase plugs and socket-outlets for household and similar purposes―Types, basic parameters and dimensions
*GB/T 2099.1-2021 Plugs and socket-outlets for household and similar purposes—Part 1: General requirements
*GBT2099.6-
*GB/T 2423.1-2008 Environmental testing - Part 2: Test methods - Tests A: Cold
*GB/T 2423.2-2008 Environmental testing - Part 2: Test methods - Tests B: Dry heat
*GB/T 2423.55-2023 Environmental testing—Part 2:Test methods—Test Eh: Hammer tests
*GB/T 5169.5-2020 Fire hazard testing for electric and electronic products—Part 5: Test flames—Needle-flame test method—Apparatus, confirmatory test arrangement and guidance
*GB/T 5465.2-2023 Graphical symbols for use on electrical equipment—Part 2:Graphical symbols
*GB/T 16842-2016 Protection of persons and equipment by enclosures-Probe for verification
*GB/T 17701-2023 Circuit-breakers for equipment (CBE)
*GB/T 17465.1-2022 Appliance couplers for household and similar general purposes—Part 1: General requirements
*GB/T 17465.6-2022 Appliance couplers for household and similar general purposes—Part 3: Standard sheets and gauges
*GB/T 17799.1-2026 Electromagnetic compatibility—Generic standards—Part 1: Immunity standard for residential, commercial and light-industrial environments
*GB 17799.3-2023 Electromagnetic compatibility (EMC)—Generic standards—Part 3: Emission standard for equipment in residential environments
*GB/T 19637-2017 Electrical accessories. Cable reels for household and similar purposes
*GB/T 20002.4-2015 Drafting for special aspects in standards―Part 4:Safety aspects for their inclusion in standards
*GB/T 20234.1-2023 Connection set for conductive charging of electric vehicles—Part 1:General requirements
*GB/T 28046.3-2011 Road vehicles—Environmental conditions and testing for electrical and electronic equipment—Part 3:Mechanical loads
*GB/T 33594-2025 Charging cables for electric vehicles
Code of China
Standard
GB 2099.7-2024  Cord extension socket-outlets for household and similar purposes―Safety technical specification (English)
Standard No.GB 2099.7-2024
Statusvalid
LanguageEnglish
File FormatPDF
Word Count21000 words
Translation Price(USD)630.0
Implemented on2025-8-1
Deliveryvia email in 1 business day
Detail of GB 2099.7-2024
Standard No.
GB 2099.7-2024
English Name
Cord extension socket-outlets for household and similar purposes―Safety technical specification
Chinese Name
家用和类似用途延长线插座 安全技术规范
Chinese Classification
K30
Professional Classification
GB
ICS Classification
Issued by
SAMR; SAC
Issued on
2024-07-24
Implemented on
2025-8-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
GB/T 2099.7-2015 Plugs and socket-outlets for household and similar purposes―Part 2-7:Particular requirements for cord extension sets
Language
English
File Format
PDF
Word Count
21000 words
Translation Price(USD)
630.0
Keywords
GB 2099.7-2024, GB/T 2099.7-2024, GBT 2099.7-2024, GB2099.7-2024, GB 2099.7, GB2099.7, GB/T2099.7-2024, GB/T 2099.7, GB/T2099.7, GBT2099.7-2024, GBT 2099.7, GBT2099.7
Introduction of GB 2099.7-2024
GB 2099.7-2024 Cord extension socket-outlets for household and similar purposes — Safety technical specification 1 Scope This document specifies the classification, main technical parameters, requirements, signs, symbols and instructions, and inspection rules for cord extension socket-outlets, and describes the corresponding test methods. This document is applicable to cord extension socket-outlets for household and similar purposes, either indoors or outdoors. This document is also applicable to portable socket-outlets intended to be connected to one flexible cable. 2 Normative references The contents in the following documents constitute essential provisions of this document through normative references in the text. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB 1002—2024 Single phase plugs and socket-outlets for household and similar purposes — Types, basic parameters and dimensions GB/T 2099.1—2021 Plugs and socket-outlets for household and similar purposes — Part 1: General requirements GB/T 2099.6 Plugs and socket-outlets for household and similar purposes — Part 2: Particular requirements for fused plugs GB/T 2423.1 Environmental testing for electric and electronic products — Part 2: Test methods — Tests A: Cold GB/T 2423.2 Environmental testing for electric and electronic products — Part 2: Test methods — Tests B: Dry heat GB/T 2423.55 Environmental testing — Part 2: Test methods — Test Eh: Hammer tests GB/T 5013 (all parts) Rubber insulated cables of rated voltages up to and including 450/750 V GB/T 5023 (all parts) Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V GB/T 5169.5—2020 Fire hazard testing for electric and electronic products — Part 5: Test flames — Needle-flame test method — Apparatus, confirmatory test arrangement and guidance GB/T 5465.2 Graphical symbols for use on electrical equipment — Part 2: Graphical symbols GB/T 13539 (all parts) Low-voltage fuses GB/T 14536 (all parts) Automatic electrical controls GB/T 16842—2016 Protection of persons and equipment by enclosures — Probe for verification GB/T 17701 Circuit-breakers for equipment (CBE) GB/T 17465.1—2022 Appliance couplers for household and similar general purposes — Part 1: General requirements GB/T 17465.6—2022 Appliance couplers for household and similar general purposes — Part 3: Standard sheets and gauges GB/T 17799.1 Electromagnetic compatibility — Generic standards — Immunity for residential, commercial and light-industrial environments GB 17799.3 Electromagnetic compatibility (EMC) — Generic standards — Part 3: Emission standard for equipment in residential environments GB/T 19637—2017 Electrical accessories — Cable reels for household and similar purposes GB/T 20002.4 Drafting for special aspects in standards — Part 4: Safety aspects for their inclusion in standards GB/T 20234.1—2023 Connection set for conductive charging of electric vehicles — Part 1: General requirements GB/T 28046.3—2011 Road vehicles — Environmental conditions and testing for electrical and electronic equipment — Part 3: Mechanical loads GB/T 33594 Charging cables for electric vehicles 3 Terms and definitions For the purposes of this document, the terms and definitions given in GB/T 2099.1—2021 and listed in the following apply. 3.1 portable socket-outlet socket-outlet intended to be connected to one flexible cable and which can easily be moved from one place to another while connected to the supply [SOURCE: GB/T 2099.1—2021, 3.4, modified] 3.2 cord extension socket-outlet assembly consisting of one portable socket-outlet and one flexible cable fitted with or without one plug 3.3 maximum operating current current that the electrical accessory can withstand and is permitted to occur only for a short duration without compromising the safety of the accessory Note 1 to entry: It shall not persist for a long period, otherwise it will cause damage to the electrical accessory. 3.4 rated power power specified by the manufacturer for the cord extension socket-outlet 3.5 appliance inlet part of the appliance coupler integrated as a part of an appliance or incorporated as a separate part in the appliance or equipment or intended to be fixed to it [SOURCE: GB/T 17465.1—2022, 3.1.2] 3.6 cord extension socket-outlet with cable reel cord extension socket-outlet provided with a device for winding the flexible cable for use, in which the surface diameter of the wound flexible cable is greater than 4 times and less than 8 times the maximum diameter of a circular flexible cable, or greater than 4 times and less than 8 times the average of the maximum and minimum dimensions of a flat flexible cable 4 Classification and main technical parameters 4.1 Classification 4.1.1 Classification by product application: —ordinary cord extension socket-outlets; —cord extension socket-outlets for charging electric bicycles; —cord extension socket-outlets supplied from electric vehicle discharge systems; —cord extension socket-outlets mounted on furniture or desktops; —cord extension socket-outlets for other applications. 4.1.2 Classification by earthing provision: —cord extension socket-outlets without earthing contacts; —cord extension socket-outlets with earthing contacts. 4.1.3 Classification by method of cable connection: —rewirable cord extension socket-outlets; —non-rewirable cord extension socket-outlets; —cord extension socket-outlets with coupler-type inlets. 4.2 Main technical parameters and ratings 4.2.1 Rated voltage The preferred value of the rated voltage is 250 V. The rated voltages of the plug and socket-outlet of an ordinary cord extension socket-outlet shall be the same. The rated voltage of the cable shall not be less than that of the plug and socket-outlet. 4.2.2 Rated current 4.2.2.1 The rated current of the plug of an ordinary cord extension socket-outlet shall not be less than that of a single socket-outlet position. For an ordinary cord extension socket-outlet with overload protection, such as a fused plug or an overcurrent protective device, the rated current of the plug shall not be less than that of the fuse or overcurrent protective device. For an ordinary cord extension socket-outlet with multiple portable socket-outlets and without an overcurrent protective device, the rated current of the plug shall be at least the smaller of the following two current values: —the arithmetic sum of the maximum currents of all plugs that can be inserted into the ordinary cord extension socket-outlet; —the rated current of the relevant socket-outlet of the fixed wiring to which the plug is intended to be connected. 4.2.2.2 The rated current of a portable socket-outlet intended to be connected to one flexible cable shall not exceed 16 A. 4.2.3 Maximum operating current of cord extension socket-outlets The maximum operating current of a cord extension socket-outlet shall be the current that can be withstood for a short duration without causing damage to the electrical accessories. The maximum operating current may be taken as the lowest among the following current values: —the rated current of the plug; —the arithmetic sum of the maximum currents of all plugs that can be inserted into the cord extension socket-outlet; —the rated current of the overcurrent protective device with the minimum rated current. 4.2.4 Rated power/maximum allowable power The rated power/maximum allowable power of the socket-outlet shall be calculated by multiplying the rated current/maximum operating current of the product by the rated voltage, with a power factor of 1. 5 Requirements 5.1 Ordinary cord extension socket-outlets 5.1.1 General requirements
Contents of GB 2099.7-2024
Contents Foreword II Introduction V 1 Scope 2 Normative references 3 Terms and definitions 4 Classification and main technical parameters 5 Requirements 6 Test methods 7 Signs, symbols and instructions 8 Inspection rules 9 Implementation of this standard Annex A (normative) Needle-flame test Annex B (normative) Safety-related routine tests for factory-wired portable socket-outlets (protection against electric shock and correct polarity) Bibliography Table 1 — Types and lengths of flexible cables and nominal cross-sectional area of conductors for cord extension socket-outlets Table 2 — Minimum overall retention force of the socket contacts of cord extension socket-outlets for charging electric bicycles Table 3 — Flexible cable length and nominal cross-sectional area of conductors of cord extension socket-outlets supplied from electric vehicle discharge systems Table 4 — Minimum overall retention force of the socket contacts of cord extension socket-outlets supplied from electric vehicle discharge systems Table B.1 — Diagrammatic representation of routine tests to be performed on portable electrical accessories with conductors as delivered
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 3680948734
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 2099.7-2024, GB/T 2099.7-2024, GBT 2099.7-2024, GB2099.7-2024, GB 2099.7, GB2099.7, GB/T2099.7-2024, GB/T 2099.7, GB/T2099.7, GBT2099.7-2024, GBT 2099.7, GBT2099.7