GB 2099.7-2024 Cord extension socket-outlets for household and similar purposes — Safety technical specification
1 Scope
This document specifies the classification, main technical parameters, requirements, signs, symbols and instructions, and inspection rules for cord extension socket-outlets, and describes the corresponding test methods.
This document is applicable to cord extension socket-outlets for household and similar purposes, either indoors or outdoors.
This document is also applicable to portable socket-outlets intended to be connected to one flexible cable.
2 Normative references
The contents in the following documents constitute essential provisions of this document through normative references in the text. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
GB 1002—2024 Single phase plugs and socket-outlets for household and similar purposes — Types, basic parameters and dimensions
GB/T 2099.1—2021 Plugs and socket-outlets for household and similar purposes — Part 1: General requirements
GB/T 2099.6 Plugs and socket-outlets for household and similar purposes — Part 2: Particular requirements for fused plugs
GB/T 2423.1 Environmental testing for electric and electronic products — Part 2: Test methods — Tests A: Cold
GB/T 2423.2 Environmental testing for electric and electronic products — Part 2: Test methods — Tests B: Dry heat
GB/T 2423.55 Environmental testing — Part 2: Test methods — Test Eh: Hammer tests
GB/T 5013 (all parts) Rubber insulated cables of rated voltages up to and including 450/750 V
GB/T 5023 (all parts) Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V
GB/T 5169.5—2020 Fire hazard testing for electric and electronic products — Part 5: Test flames — Needle-flame test method — Apparatus, confirmatory test arrangement and guidance
GB/T 5465.2 Graphical symbols for use on electrical equipment — Part 2: Graphical symbols
GB/T 13539 (all parts) Low-voltage fuses
GB/T 14536 (all parts) Automatic electrical controls
GB/T 16842—2016 Protection of persons and equipment by enclosures — Probe for verification
GB/T 17701 Circuit-breakers for equipment (CBE)
GB/T 17465.1—2022 Appliance couplers for household and similar general purposes — Part 1: General requirements
GB/T 17465.6—2022 Appliance couplers for household and similar general purposes — Part 3: Standard sheets and gauges
GB/T 17799.1 Electromagnetic compatibility — Generic standards — Immunity for residential, commercial and light-industrial environments
GB 17799.3 Electromagnetic compatibility (EMC) — Generic standards — Part 3: Emission standard for equipment in residential environments
GB/T 19637—2017 Electrical accessories — Cable reels for household and similar purposes
GB/T 20002.4 Drafting for special aspects in standards — Part 4: Safety aspects for their inclusion in standards
GB/T 20234.1—2023 Connection set for conductive charging of electric vehicles — Part 1: General requirements
GB/T 28046.3—2011 Road vehicles — Environmental conditions and testing for electrical and electronic equipment — Part 3: Mechanical loads
GB/T 33594 Charging cables for electric vehicles
3 Terms and definitions
For the purposes of this document, the terms and definitions given in GB/T 2099.1—2021 and listed in the following apply.
3.1
portable socket-outlet
socket-outlet intended to be connected to one flexible cable and which can easily be moved from one place to another while connected to the supply
[SOURCE: GB/T 2099.1—2021, 3.4, modified]
3.2
cord extension socket-outlet
assembly consisting of one portable socket-outlet and one flexible cable fitted with or without one plug
3.3
maximum operating current
current that the electrical accessory can withstand and is permitted to occur only for a short duration without compromising the safety of the accessory
Note 1 to entry: It shall not persist for a long period, otherwise it will cause damage to the electrical accessory.
3.4
rated power
power specified by the manufacturer for the cord extension socket-outlet
3.5
appliance inlet
part of the appliance coupler integrated as a part of an appliance or incorporated as a separate part in the appliance or equipment or intended to be fixed to it
[SOURCE: GB/T 17465.1—2022, 3.1.2]
3.6
cord extension socket-outlet with cable reel
cord extension socket-outlet provided with a device for winding the flexible cable for use, in which the surface diameter of the wound flexible cable is greater than 4 times and less than 8 times the maximum diameter of a circular flexible cable, or greater than 4 times and less than 8 times the average of the maximum and minimum dimensions of a flat flexible cable
4 Classification and main technical parameters
4.1 Classification
4.1.1 Classification by product application:
—ordinary cord extension socket-outlets;
—cord extension socket-outlets for charging electric bicycles;
—cord extension socket-outlets supplied from electric vehicle discharge systems;
—cord extension socket-outlets mounted on furniture or desktops;
—cord extension socket-outlets for other applications.
4.1.2 Classification by earthing provision:
—cord extension socket-outlets without earthing contacts;
—cord extension socket-outlets with earthing contacts.
4.1.3 Classification by method of cable connection:
—rewirable cord extension socket-outlets;
—non-rewirable cord extension socket-outlets;
—cord extension socket-outlets with coupler-type inlets.
4.2 Main technical parameters and ratings
4.2.1 Rated voltage
The preferred value of the rated voltage is 250 V.
The rated voltages of the plug and socket-outlet of an ordinary cord extension socket-outlet shall be the same.
The rated voltage of the cable shall not be less than that of the plug and socket-outlet.
4.2.2 Rated current
4.2.2.1 The rated current of the plug of an ordinary cord extension socket-outlet shall not be less than that of a single socket-outlet position.
For an ordinary cord extension socket-outlet with overload protection, such as a fused plug or an overcurrent protective device, the rated current of the plug shall not be less than that of the fuse or overcurrent protective device.
For an ordinary cord extension socket-outlet with multiple portable socket-outlets and without an overcurrent protective device, the rated current of the plug shall be at least the smaller of the following two current values:
—the arithmetic sum of the maximum currents of all plugs that can be inserted into the ordinary cord extension socket-outlet;
—the rated current of the relevant socket-outlet of the fixed wiring to which the plug is intended to be connected.
4.2.2.2 The rated current of a portable socket-outlet intended to be connected to one flexible cable shall not exceed 16 A.
4.2.3 Maximum operating current of cord extension socket-outlets
The maximum operating current of a cord extension socket-outlet shall be the current that can be withstood for a short duration without causing damage to the electrical accessories. The maximum operating current may be taken as the lowest among the following current values:
—the rated current of the plug;
—the arithmetic sum of the maximum currents of all plugs that can be inserted into the cord extension socket-outlet;
—the rated current of the overcurrent protective device with the minimum rated current.
4.2.4 Rated power/maximum allowable power
The rated power/maximum allowable power of the socket-outlet shall be calculated by multiplying the rated current/maximum operating current of the product by the rated voltage, with a power factor of 1.
5 Requirements
5.1 Ordinary cord extension socket-outlets
5.1.1 General requirements
Contents
Foreword II
Introduction V
1 Scope
2 Normative references
3 Terms and definitions
4 Classification and main technical parameters
5 Requirements
6 Test methods
7 Signs, symbols and instructions
8 Inspection rules
9 Implementation of this standard
Annex A (normative) Needle-flame test
Annex B (normative) Safety-related routine tests for factory-wired portable socket-outlets (protection against electric shock and correct polarity)
Bibliography
Table 1 — Types and lengths of flexible cables and nominal cross-sectional area of conductors for cord extension socket-outlets
Table 2 — Minimum overall retention force of the socket contacts of cord extension socket-outlets for charging electric bicycles
Table 3 — Flexible cable length and nominal cross-sectional area of conductors of cord extension socket-outlets supplied from electric vehicle discharge systems
Table 4 — Minimum overall retention force of the socket contacts of cord extension socket-outlets supplied from electric vehicle discharge systems
Table B.1 — Diagrammatic representation of routine tests to be performed on portable electrical accessories with conductors as delivered
GB 2099.7-2024 Cord extension socket-outlets for household and similar purposes — Safety technical specification
1 Scope
This document specifies the classification, main technical parameters, requirements, signs, symbols and instructions, and inspection rules for cord extension socket-outlets, and describes the corresponding test methods.
This document is applicable to cord extension socket-outlets for household and similar purposes, either indoors or outdoors.
This document is also applicable to portable socket-outlets intended to be connected to one flexible cable.
2 Normative references
The contents in the following documents constitute essential provisions of this document through normative references in the text. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
GB 1002—2024 Single phase plugs and socket-outlets for household and similar purposes — Types, basic parameters and dimensions
GB/T 2099.1—2021 Plugs and socket-outlets for household and similar purposes — Part 1: General requirements
GB/T 2099.6 Plugs and socket-outlets for household and similar purposes — Part 2: Particular requirements for fused plugs
GB/T 2423.1 Environmental testing for electric and electronic products — Part 2: Test methods — Tests A: Cold
GB/T 2423.2 Environmental testing for electric and electronic products — Part 2: Test methods — Tests B: Dry heat
GB/T 2423.55 Environmental testing — Part 2: Test methods — Test Eh: Hammer tests
GB/T 5013 (all parts) Rubber insulated cables of rated voltages up to and including 450/750 V
GB/T 5023 (all parts) Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V
GB/T 5169.5—2020 Fire hazard testing for electric and electronic products — Part 5: Test flames — Needle-flame test method — Apparatus, confirmatory test arrangement and guidance
GB/T 5465.2 Graphical symbols for use on electrical equipment — Part 2: Graphical symbols
GB/T 13539 (all parts) Low-voltage fuses
GB/T 14536 (all parts) Automatic electrical controls
GB/T 16842—2016 Protection of persons and equipment by enclosures — Probe for verification
GB/T 17701 Circuit-breakers for equipment (CBE)
GB/T 17465.1—2022 Appliance couplers for household and similar general purposes — Part 1: General requirements
GB/T 17465.6—2022 Appliance couplers for household and similar general purposes — Part 3: Standard sheets and gauges
GB/T 17799.1 Electromagnetic compatibility — Generic standards — Immunity for residential, commercial and light-industrial environments
GB 17799.3 Electromagnetic compatibility (EMC) — Generic standards — Part 3: Emission standard for equipment in residential environments
GB/T 19637—2017 Electrical accessories — Cable reels for household and similar purposes
GB/T 20002.4 Drafting for special aspects in standards — Part 4: Safety aspects for their inclusion in standards
GB/T 20234.1—2023 Connection set for conductive charging of electric vehicles — Part 1: General requirements
GB/T 28046.3—2011 Road vehicles — Environmental conditions and testing for electrical and electronic equipment — Part 3: Mechanical loads
GB/T 33594 Charging cables for electric vehicles
3 Terms and definitions
For the purposes of this document, the terms and definitions given in GB/T 2099.1—2021 and listed in the following apply.
3.1
portable socket-outlet
socket-outlet intended to be connected to one flexible cable and which can easily be moved from one place to another while connected to the supply
[SOURCE: GB/T 2099.1—2021, 3.4, modified]
3.2
cord extension socket-outlet
assembly consisting of one portable socket-outlet and one flexible cable fitted with or without one plug
3.3
maximum operating current
current that the electrical accessory can withstand and is permitted to occur only for a short duration without compromising the safety of the accessory
Note 1 to entry: It shall not persist for a long period, otherwise it will cause damage to the electrical accessory.
3.4
rated power
power specified by the manufacturer for the cord extension socket-outlet
3.5
appliance inlet
part of the appliance coupler integrated as a part of an appliance or incorporated as a separate part in the appliance or equipment or intended to be fixed to it
[SOURCE: GB/T 17465.1—2022, 3.1.2]
3.6
cord extension socket-outlet with cable reel
cord extension socket-outlet provided with a device for winding the flexible cable for use, in which the surface diameter of the wound flexible cable is greater than 4 times and less than 8 times the maximum diameter of a circular flexible cable, or greater than 4 times and less than 8 times the average of the maximum and minimum dimensions of a flat flexible cable
4 Classification and main technical parameters
4.1 Classification
4.1.1 Classification by product application:
—ordinary cord extension socket-outlets;
—cord extension socket-outlets for charging electric bicycles;
—cord extension socket-outlets supplied from electric vehicle discharge systems;
—cord extension socket-outlets mounted on furniture or desktops;
—cord extension socket-outlets for other applications.
4.1.2 Classification by earthing provision:
—cord extension socket-outlets without earthing contacts;
—cord extension socket-outlets with earthing contacts.
4.1.3 Classification by method of cable connection:
—rewirable cord extension socket-outlets;
—non-rewirable cord extension socket-outlets;
—cord extension socket-outlets with coupler-type inlets.
4.2 Main technical parameters and ratings
4.2.1 Rated voltage
The preferred value of the rated voltage is 250 V.
The rated voltages of the plug and socket-outlet of an ordinary cord extension socket-outlet shall be the same.
The rated voltage of the cable shall not be less than that of the plug and socket-outlet.
4.2.2 Rated current
4.2.2.1 The rated current of the plug of an ordinary cord extension socket-outlet shall not be less than that of a single socket-outlet position.
For an ordinary cord extension socket-outlet with overload protection, such as a fused plug or an overcurrent protective device, the rated current of the plug shall not be less than that of the fuse or overcurrent protective device.
For an ordinary cord extension socket-outlet with multiple portable socket-outlets and without an overcurrent protective device, the rated current of the plug shall be at least the smaller of the following two current values:
—the arithmetic sum of the maximum currents of all plugs that can be inserted into the ordinary cord extension socket-outlet;
—the rated current of the relevant socket-outlet of the fixed wiring to which the plug is intended to be connected.
4.2.2.2 The rated current of a portable socket-outlet intended to be connected to one flexible cable shall not exceed 16 A.
4.2.3 Maximum operating current of cord extension socket-outlets
The maximum operating current of a cord extension socket-outlet shall be the current that can be withstood for a short duration without causing damage to the electrical accessories. The maximum operating current may be taken as the lowest among the following current values:
—the rated current of the plug;
—the arithmetic sum of the maximum currents of all plugs that can be inserted into the cord extension socket-outlet;
—the rated current of the overcurrent protective device with the minimum rated current.
4.2.4 Rated power/maximum allowable power
The rated power/maximum allowable power of the socket-outlet shall be calculated by multiplying the rated current/maximum operating current of the product by the rated voltage, with a power factor of 1.
5 Requirements
5.1 Ordinary cord extension socket-outlets
5.1.1 General requirements
Contents of GB 2099.7-2024
Contents
Foreword II
Introduction V
1 Scope
2 Normative references
3 Terms and definitions
4 Classification and main technical parameters
5 Requirements
6 Test methods
7 Signs, symbols and instructions
8 Inspection rules
9 Implementation of this standard
Annex A (normative) Needle-flame test
Annex B (normative) Safety-related routine tests for factory-wired portable socket-outlets (protection against electric shock and correct polarity)
Bibliography
Table 1 — Types and lengths of flexible cables and nominal cross-sectional area of conductors for cord extension socket-outlets
Table 2 — Minimum overall retention force of the socket contacts of cord extension socket-outlets for charging electric bicycles
Table 3 — Flexible cable length and nominal cross-sectional area of conductors of cord extension socket-outlets supplied from electric vehicle discharge systems
Table 4 — Minimum overall retention force of the socket contacts of cord extension socket-outlets supplied from electric vehicle discharge systems
Table B.1 — Diagrammatic representation of routine tests to be performed on portable electrical accessories with conductors as delivered