1 Scope
This standard specifies the examination method for Listeria monocytogenes in food.
This standard is applicable to the examination of Listeria monocytogenes in food.
2 Equipment and Materials
In addition to the conventional aseptic equipment and culture equipment of microbiological laboratory, other equipment and materials needed for the examination are as follows:
2.1 Refrigerator: 2℃~5℃.
2.2 Constant temperature incubator: 30℃±1℃, 36℃±1℃.
2.3 Homogenizer.
2.4 Microscope: 10×~100×.
2.5 Electronic balance: sensibility of 0.1g.
2.6 Conical flask: 100mL, 500mL.
2.7 Aseptic suction tube: 1mL (scale division of 0.01mL) and 10mL (scale division of 0.1mL).
2.8 Aseptic petri dish: in diameter of 90mm.
2.9 Aseptic test tube: 16 mm×160 mm.
2.10 Centrifuge tube: 30 mm×100 mm.
2.11 Aseptic injector: 1mL.
2.12 Staphylococcus aureus (ATCC25923).
2.13 Rhodococcus equi.
2.14 Mouse: 16 g~18 g.
2.15 Full-automatic microbe biochemical verification system.
3 Culture Mediums and Reagents
Foreword I
1 Scope
2 Equipment and Materials
3 Culture Mediums and Reagents
4 Examination Procedures
5 Operation Procedures
6 Result and Report
Appendix A (Normative) Culture Mediums and Reagents
Standard
GB 4789.30-2010 National food safety standard Food microbiological examination:Listeria monocytogenes (English Version)
Standard No.
GB 4789.30-2010
Status
superseded
Language
English
File Format
PDF
Word Count
3000 words
Price(USD)
60.0
Implemented on
2010-6-1
Delivery
via email in 1 business day
Detail of GB 4789.30-2010
Standard No.
GB 4789.30-2010
English Name
National food safety standard Food microbiological examination:Listeria monocytogenes
1 Scope
This standard specifies the examination method for Listeria monocytogenes in food.
This standard is applicable to the examination of Listeria monocytogenes in food.
2 Equipment and Materials
In addition to the conventional aseptic equipment and culture equipment of microbiological laboratory, other equipment and materials needed for the examination are as follows:
2.1 Refrigerator: 2℃~5℃.
2.2 Constant temperature incubator: 30℃±1℃, 36℃±1℃.
2.3 Homogenizer.
2.4 Microscope: 10×~100×.
2.5 Electronic balance: sensibility of 0.1g.
2.6 Conical flask: 100mL, 500mL.
2.7 Aseptic suction tube: 1mL (scale division of 0.01mL) and 10mL (scale division of 0.1mL).
2.8 Aseptic petri dish: in diameter of 90mm.
2.9 Aseptic test tube: 16 mm×160 mm.
2.10 Centrifuge tube: 30 mm×100 mm.
2.11 Aseptic injector: 1mL.
2.12 Staphylococcus aureus (ATCC25923).
2.13 Rhodococcus equi.
2.14 Mouse: 16 g~18 g.
2.15 Full-automatic microbe biochemical verification system.
3 Culture Mediums and Reagents
Contents of GB 4789.30-2010
Foreword I
1 Scope
2 Equipment and Materials
3 Culture Mediums and Reagents
4 Examination Procedures
5 Operation Procedures
6 Result and Report
Appendix A (Normative) Culture Mediums and Reagents