2023-2-6 3.236.70.233
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB 50877-2014
GB 50877-2014   Code for Installation and Acceptance of Fire Resistant Shutters, Fire Resistant Doorsets and Fire Resistant Windows (English Version)
Standard No.: GB 50877-2014 Status:valid remind me the status change

Email:

Language:English File Format:PDF
Word Count: 25000 words Price(USD):360.0 remind me the price change

Email:

Implemented on:2014-8-1 Delivery: via email in 1 business day
,,
Standard No.: GB 50877-2014
English Name: Code for Installation and Acceptance of Fire Resistant Shutters, Fire Resistant Doorsets and Fire Resistant Windows
Chinese Name: 防火卷帘、防火门、防火窗施工及验收规范
Chinese Classification: P16    Engineering fire protection
Professional Classification: GB    National Standard
Issued by: MOHURD and AQSIQ
Issued on: 2014-01-09
Implemented on: 2014-8-1
Status: valid
Language: English
File Format: PDF
Word Count: 25000 words
Price(USD): 360.0
Delivery: via email in 1 business day
1 General Provisions 1.0.1 This code is formulated in order to the quality and service function during the installation of fire resistant shutters, fire resistant doorsets and fire resistant windows, reduce fire hazards and protect personal and property safety. 1.0.2 This code is applicable to the installation, acceptance and maintenance management of fire resistant shutters, fire resistant doorsets and fire resistant windows for construction, extension and renovation. 1.0.3 The requirements for installation and acceptance specified in relevant engineering documents and contracts for installing and acceptance of fire resistant shutters, fire resistant doorsets and fire resistant windows shall at least meet those specified in this code. 1.0.4 Installation, acceptance and maintenance management of fire resistant shutters, fire resistant doorsets and fire resistant windows shall not only meet the requirements stipulated in this code, but also comply with those specified in the current relevant national standards. 2 Terms 2.0.1 Fire resistant shutter A kind of facility with its frame to be capable of fire prevention and thermal insulation in a certain period of time. 2.0.2 Steel fire resistant shutter A kind of facility, equipped with door roller and control box, whose slat, guide rail, riser plate, lintel and box are made of steel materials. 2.0.3 Mineral fiber composites fire resistant shutter A kind of facility, equipped with door roller and control box, whose shutter surface (equipped with stainless steel wire or rope) is made of mineral fibers, clamp plate, guide rail, riser plate, lintel and box are of steel materials. 2.0.4 Fire resistant doorset A kind of door with its frame to be capable of fire prevention and thermal insulation in a certain period of time. 2.0.5 Fire resistant window A kind of window with its frame to be capable of fire prevention and thermal insulation in a certain period of time. 2.0.6 Fixed style fire window The fire resistant window without openable sashes. 2.0.7 Automatic-controlled fire window The fire resistant window equipped with openable sashes and a device to control them. 2.0.8 Thermal release device A device that can make fire resistant shutters or fire resistant windows descend or close by their own dead-weight with the aid of temperature-sensing element whose operating temperature is 73℃±0.5℃.
1 General Provisions 2 Terms 3 Basic Requirement 4 Inspection 4.1 General Requirement 4.2 Fire Resistant Shutters Inspection 4.3 Fire Resistant Doorsets Inspection 4.4 Fire Resistant Windows Inspection 5 Installation 5.1 General Requirement 5.2 Fire Resistant Shutters Installation 5.3 Fire Resistant Doorsets Installation 5.4 Fire Resistant Windows Installation 6 Commissioning 6.1 General Requirement 6.2 Fire Resistant Shutters Commissioning 6.3 Fire Resistant Doorsets Commissioning 6.4 Fire Resistant Windows Commissioning 7 Acceptance Test 7.1 General Requirement 7.2 Fire Resistant Shutters Acceptance 7.3 Fire Resistant Doorsets Acceptance 7.4 Fire Resistant Windows Acceptance 8 Maintenance and Management Appendix A Inspection Records for Quality Management of Construction Site Appendix B Project Stages of Fire Resistant Shutters, Fire Resistant Doorsets and Fire Resistant Windows Appendix C Inspection Record for Installation Process of Fire Resistant Shutters, Fire Resistant Doorsets and Fire Resistant Windows Appendix D Acceptance Test Record for Fire Resistant Shutters, Fire Resistant Doorsets and Fire Resistant Windows Appendix E Inspection, Application and Management Record for Fire Resistant Shutters, Fire Resistant Doorsets and Fire Resistant Windows Explanation of Wording in this Code List of Quoted Standards
Referred in GB 50877-2014:
*GB 50016-2014(2018) Code for Fire Protection Design of Buildings - Partial Revision -2018
*GB 50116-2013 Code for design of automatic fire alarm system
*GB 50261-2017 Code for installation and commissioning of sprinkler systems
Code of China
Standard
GB 50877-2014  Code for Installation and Acceptance of Fire Resistant Shutters, Fire Resistant Doorsets and Fire Resistant Windows (English Version)
Standard No.GB 50877-2014
Statusvalid
LanguageEnglish
File FormatPDF
Word Count25000 words
Price(USD)360.0
Implemented on2014-8-1
Deliveryvia email in 1 business day
Detail of GB 50877-2014
Standard No.
GB 50877-2014
English Name
Code for Installation and Acceptance of Fire Resistant Shutters, Fire Resistant Doorsets and Fire Resistant Windows
Chinese Name
防火卷帘、防火门、防火窗施工及验收规范
Chinese Classification
P16
Professional Classification
GB
ICS Classification
Issued by
MOHURD and AQSIQ
Issued on
2014-01-09
Implemented on
2014-8-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
25000 words
Price(USD)
360.0
Keywords
GB 50877-2014, GB/T 50877-2014, GBT 50877-2014, GB50877-2014, GB 50877, GB50877, GB/T50877-2014, GB/T 50877, GB/T50877, GBT50877-2014, GBT 50877, GBT50877
Introduction of GB 50877-2014
1 General Provisions 1.0.1 This code is formulated in order to the quality and service function during the installation of fire resistant shutters, fire resistant doorsets and fire resistant windows, reduce fire hazards and protect personal and property safety. 1.0.2 This code is applicable to the installation, acceptance and maintenance management of fire resistant shutters, fire resistant doorsets and fire resistant windows for construction, extension and renovation. 1.0.3 The requirements for installation and acceptance specified in relevant engineering documents and contracts for installing and acceptance of fire resistant shutters, fire resistant doorsets and fire resistant windows shall at least meet those specified in this code. 1.0.4 Installation, acceptance and maintenance management of fire resistant shutters, fire resistant doorsets and fire resistant windows shall not only meet the requirements stipulated in this code, but also comply with those specified in the current relevant national standards. 2 Terms 2.0.1 Fire resistant shutter A kind of facility with its frame to be capable of fire prevention and thermal insulation in a certain period of time. 2.0.2 Steel fire resistant shutter A kind of facility, equipped with door roller and control box, whose slat, guide rail, riser plate, lintel and box are made of steel materials. 2.0.3 Mineral fiber composites fire resistant shutter A kind of facility, equipped with door roller and control box, whose shutter surface (equipped with stainless steel wire or rope) is made of mineral fibers, clamp plate, guide rail, riser plate, lintel and box are of steel materials. 2.0.4 Fire resistant doorset A kind of door with its frame to be capable of fire prevention and thermal insulation in a certain period of time. 2.0.5 Fire resistant window A kind of window with its frame to be capable of fire prevention and thermal insulation in a certain period of time. 2.0.6 Fixed style fire window The fire resistant window without openable sashes. 2.0.7 Automatic-controlled fire window The fire resistant window equipped with openable sashes and a device to control them. 2.0.8 Thermal release device A device that can make fire resistant shutters or fire resistant windows descend or close by their own dead-weight with the aid of temperature-sensing element whose operating temperature is 73℃±0.5℃.
Contents of GB 50877-2014
1 General Provisions 2 Terms 3 Basic Requirement 4 Inspection 4.1 General Requirement 4.2 Fire Resistant Shutters Inspection 4.3 Fire Resistant Doorsets Inspection 4.4 Fire Resistant Windows Inspection 5 Installation 5.1 General Requirement 5.2 Fire Resistant Shutters Installation 5.3 Fire Resistant Doorsets Installation 5.4 Fire Resistant Windows Installation 6 Commissioning 6.1 General Requirement 6.2 Fire Resistant Shutters Commissioning 6.3 Fire Resistant Doorsets Commissioning 6.4 Fire Resistant Windows Commissioning 7 Acceptance Test 7.1 General Requirement 7.2 Fire Resistant Shutters Acceptance 7.3 Fire Resistant Doorsets Acceptance 7.4 Fire Resistant Windows Acceptance 8 Maintenance and Management Appendix A Inspection Records for Quality Management of Construction Site Appendix B Project Stages of Fire Resistant Shutters, Fire Resistant Doorsets and Fire Resistant Windows Appendix C Inspection Record for Installation Process of Fire Resistant Shutters, Fire Resistant Doorsets and Fire Resistant Windows Appendix D Acceptance Test Record for Fire Resistant Shutters, Fire Resistant Doorsets and Fire Resistant Windows Appendix E Inspection, Application and Management Record for Fire Resistant Shutters, Fire Resistant Doorsets and Fire Resistant Windows Explanation of Wording in this Code List of Quoted Standards
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Foryou Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 50877-2014, GB/T 50877-2014, GBT 50877-2014, GB50877-2014, GB 50877, GB50877, GB/T50877-2014, GB/T 50877, GB/T50877, GBT50877-2014, GBT 50877, GBT50877