GB 50116-2013   Code for design of automatic fire alarm system (English Version)
Standard No.: GB 50116-2013 Status:valid remind me the status change

Email:

Language:English File Format:PDF
Word Count: 22000 words Price(USD):140.0 remind me the price change

Email:

Implemented on:2014-5-1 Delivery: via email in 1 business day
,,
Standard No.: GB 50116-2013
English Name: Code for design of automatic fire alarm system
Chinese Name: 火灾自动报警系统设计规范
Professional Classification: GB    National Standard
Issued by: MOHURD
Issued on: 2013-09-06
Implemented on: 2014-5-1
Status: valid
Superseding:GB 50116-1998 Code for Design of Automatic Fire Alarm System
Language: English
File Format: PDF
Word Count: 22000 words
Price(USD): 140.0
Delivery: via email in 1 business day
1.0.1 This code is formulated with view to rational design of automatic fire alarm system, prevention and reduction of fire hazards and protection of the personal and property safety. 1.0.2 This code is applicable to design of automatic fire alarm system located in the constructed, renovated and extended building and structure but not applicable to that located at the places for production and storage of gunpowder, explosive, ammunition and explosive device. 1.0.3 Aimed at the features of the protected objects, the design of automatic fire alarm system shall comply with the relevant national guideline and policy and realize the safety and reliability, advanced technology and economic feasibility. 1.0.4 The design of automatic fire alarm system shall not only comply with this code but those in the current relevant standards of the nation.
Foreword I 1 General Provisions 2 Terms 3 Basic Requirement 3.1 General Requirements 3.2 Choice and Design of System 3.3 Division of the Alarm Zone and Detection Zone 3.4 Fire Control Center 4 Automatic Control Design 4.1 General Requirements 4.2 Automatic Control Design of the Automatic Sprinkler System 4.3 Automatic Control Design of Fire Hydrant System 4.4 Automatic Control Design of Gases (Bubble) Fire-extinguishing System 4.5 Automatic Control Design of Smoke Exhaust System 4.6 Automatic Control Design of Fire Door and Fire Roller Shutter System 4.7 Automatic Control Design of Elevator 4.8 Automatic Control Design of the Fire Alarm and Signalling Device 4.9 Automatic Control Design of the Fire Emergency Lighting System 4.10 Automatic Control Design of the Related Equipment 5 Fire Detector Choice 5.1 General Requirements 5.2 Choice of Point Type Fire Detector 5.3 Choice of Line type Fire Detector 5.4 Choice of Aspirating Smoke Detector 6 Setting of the Equipment 6.1 Setting of the Fire Alarm Control Unit and Automatic Control Equipment 6.2 Setting of the Fire Detector 6.3 Setting of the Manual Call Point 6.4 Setting of the Fire Display Panel 6.5 Setting of the Fire Alarm Singalling Device 6.6 Setting of the Sounder Equipment for Fire Emergency Purposes 6.7 Setting of the Fire Telephone 6.8 Setting of the Module 6.9 Setting of the Graph Indicator in Fire Control Center 6.10 Setting of the Routing Equipment 6.11 Setting of the Indicator and Control Unit for Fire Doors 7 Fire Alarm and Safety System Installed in Dwelling Building 7.1 General Requirement 7.2 System Design 7.3 Setting of the Fire Detector 7.4 Setting of the Fire Alarm Control Unit for Household 7.5 Setting of the Fire Alarm Signalling Device 7.6 Setting of the Emergency Broadcast Device 8 Combustible Gas Detection and Alarm System 8.1 General Requirement 8.2 Setting of the Combustible Gas Detector 8.3 Setting of the Combustible Gas Control Unit 9 Alarm and Monitoring System for Electric Fire Protection 9.1 General Requirement 9.2 Setting of the Leakage Current Detector for Electric Fire Prevention 9.3 Setting of the Heat Detector for Electric Fire Prevention 9.4 Setting of the Independent Detector for Electric Fire Prevention 9.5 Setting of the Alarm and Control Unit for Electric Fire Protection 10 Power Supply 10.1 General Requirement 10.2 Ground Connection 11 Wiring 11.1 General Requirement 11.2 Interior Wiring 12 Automatic Fire Alarm System for Typical Place 12.1 The Traffic Tunnel 12.2 The Oil Tank Area 12.3 The Cable Tunnel 12.4 The Large Space Places Where Higher than 12m Appendix A Operating Status Information Table for Fire Alarm & the Fire Equipment in the Building Appendix B Fire Safety Management Information Table Appendix C Classification for the Point Type Heat Detectors Appendix D Specific Setting of the Detectors Appendix E Limit Curve for Install Space of the Detectors Appendix F Setting of Detectors Influenced by Roof Beam Appendix G Number of the Roof Beams Protected by One Detector Based on the Roof Beams Area Explanation of Wording in This Code List of Quoted Standards
Referred in GB 50116-2013:
*GB 50493-2009 Specification for Design of Combustible Gas and Toxic Gas Detection and Alarm for Petrochemical Industry
*GB 4715-2005 Smoke Detectors—Point Detectors Using Scattered Light, Transmitted
*GB 4716-2005 Point type heat fire detectors
*GB 4717-2005 Fire alarm control units
*GB 16806-2006/XG1-2016 Automatic control system for fire protection
*GB 19880-2005 Manual Fire Call Points
*GB 22134-2008 Compatibility Requirements of Automatic Fire Alarm System Components
*GB 25506-2010 General technical requirements for fire control center
GB 50116-2013 is referred in:
* GB 50059-2011 Code for Design of 35kV~110kV Substation
* GB 50660-2011 Code for Designing large and Middle Fossil Fuel Power Plant
* JGJ 218-2010 Design code for exhibition building
* GB 50606-2010 Code for installation of Intelligented building system
* GB 50565-2010 Code for design of textile engineering on fire protection and prevention
* GB 50620-2010 Code for design of viscose fibre plant
* GB 50073-2013 Code for design of clean room
* GB/T 2887-2011 General specification for computer field
* GB 50016-2014 Code of Design on Building Fire Protection and Prevention
* GB 50151-2010 Code for design of foam extinguishing systems
* GB 50016-2014 Code of Design on Building Fire Protection and Prevention
* GB 50073-2013 Code for design of clean room
* GB 50016-2014 Code of Design on Building Fire Protection and Prevention
* GB 50016-2014 Code of Design on Building Fire Protection and Prevention
* GB 50073-2013 Code for design of clean room
* GB 50059-2011 Code for Design of 35kV~110kV Substation
* GB 50660-2011 Code for Designing large and Middle Fossil Fuel Power Plant
* GB/T 2887-2011 General specification for computer field
* GB 50151-2010 Code for design of foam extinguishing systems
* GB 50620-2010 Code for design of viscose fibre plant
* JGJ 218-2010 Design code for exhibition building
* GB 50565-2010 Code for design of textile engineering on fire protection and prevention
* GB 50606-2010 Code for installation of Intelligented building system
* GB 50016-2014 Code of Design on Building Fire Protection and Prevention
* GB 50016-2014 Code of Design on Building Fire Protection and Prevention
* GB 50073-2013 Code for design of clean room
* GB 50073-2013 Code for design of clean room
* GB 50074-2014 Code for Design of Oil Depot
* DL/T 5227-2005 Technical Rule of Thermal Power Automation Design for Auxiliary S
* GB 50073-2013 Code for design of clean room
* GB 50016-2014 Code of Design on Building Fire Protection and Prevention
* GB 50016-2014 Code of Design on Building Fire Protection and Prevention
* GB 50016-2014 Code of Design on Building Fire Protection and Prevention
* GB 50016-2014 Code of Design on Building Fire Protection and Prevention
* GB 50016-2014 Code of Design on Building Fire Protection and Prevention
* GB 50016-2014 Code of Design on Building Fire Protection and Prevention
* GB 50877-2014 Code for Installation and Acceptance of Fire Resistant Shutters, Fire Resistant Doorsets and Fire Resistant Windows
* GB 50115-2009 Code for design of industrial television system
* JGJ 62-2014 Code for Design of Hotel Building
* SH/T 3006-2012 Specification for design of control room in petrochemical industry
* GB 51039-2014 Code for design of general hospital
* JGJ 312-2013 Code for Electrical Design of Medical Buildings
* GB 50219-2014 Technical Code for water spray fire protection systems
* GB 50314-2015 Standard for design of intelligent building
* GB 50157-2013 Code for Design of Metro
* GB 50251-2015 Design code for gas transmission pipeline engineering
* GB 51093-2015 Technical code for hydrochloric acid regeneration engineering according to spraying and roasting technology of iron and steel enterprises
* GB 50019-2015 Code for Design of Heating Ventilation and Air Conditioning in Industrial Buildings
* JGJ 66-2015
*CECS 263-2009 Technical specification for large-space intelligent active control sprinkler systems
*GA 654-2006 Standard for fire safety management of assembly occupancies
*GB 50174-2017 Code for Design of Data Centers
*GB 25506-2010 General technical requirements for fire control center
*YD/T 2057-2009 General requirements of Safety management for telecommunication room
*GB/T 34584-2017 Safety technical regulations for hydrogen refueling station
*GA 1290-2016 Rules for examination of building fire safety design
*DB11/755-2010 Safety Code for Construction and Storage of Dangerous Chemicals Warehouse
*GB 50457-2019 Code for design of pharmaceutical industry clean room
*GB 51283-2020 Fire protection standard for engineering design of fine chemical enterprise
*GB 50454-2020 Standard for design of aero-engine test cell
*GB 50041-2020 Standard for design of boiler plant
*HG 20571-2014 Code for Safety and Hygiene Design of Chemical Enterprise
*GB 51156-2015 Code for design of liquefied natural gas receiving terminal
*SY/T 6633-2019 Guide of emergency alarms for offshore petroleum installations
*GB 51427-2021 Technical standard for auto tracking and targeting jet suppression system
*GB/T 50115-2019 Standard for design of industrrial television system
*GB 50414-2018 Standard for fire protection design of iron and steel metallurgy enterprises
*GB 50229-2019 Standard for design of fire protection for fossil fuel power plants and substations
*AQ 3036-2010 Setting specifications for safety monitoring and controlling equipments in dangerous chemicals major hazard installations Tanks section
*GB 50151-2021 Technical standard for foam extinguishing systems
*GB/T 16507.7-2022 Water-tube Boilers - Part 7: Safety Appurtenances and Instruments
Code of China
Standard
GB 50116-2013  Code for design of automatic fire alarm system (English Version)
Standard No.GB 50116-2013
Statusvalid
LanguageEnglish
File FormatPDF
Word Count22000 words
Price(USD)140.0
Implemented on2014-5-1
Deliveryvia email in 1 business day
Detail of GB 50116-2013
Standard No.
GB 50116-2013
English Name
Code for design of automatic fire alarm system
Chinese Name
火灾自动报警系统设计规范
Chinese Classification
Professional Classification
GB
ICS Classification
Issued by
MOHURD
Issued on
2013-09-06
Implemented on
2014-5-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
GB 50116-1998 Code for Design of Automatic Fire Alarm System
Language
English
File Format
PDF
Word Count
22000 words
Price(USD)
140.0
Keywords
GB 50116-2013, GB/T 50116-2013, GBT 50116-2013, GB50116-2013, GB 50116, GB50116, GB/T50116-2013, GB/T 50116, GB/T50116, GBT50116-2013, GBT 50116, GBT50116
Introduction of GB 50116-2013
1.0.1 This code is formulated with view to rational design of automatic fire alarm system, prevention and reduction of fire hazards and protection of the personal and property safety. 1.0.2 This code is applicable to design of automatic fire alarm system located in the constructed, renovated and extended building and structure but not applicable to that located at the places for production and storage of gunpowder, explosive, ammunition and explosive device. 1.0.3 Aimed at the features of the protected objects, the design of automatic fire alarm system shall comply with the relevant national guideline and policy and realize the safety and reliability, advanced technology and economic feasibility. 1.0.4 The design of automatic fire alarm system shall not only comply with this code but those in the current relevant standards of the nation.
Contents of GB 50116-2013
Foreword I 1 General Provisions 2 Terms 3 Basic Requirement 3.1 General Requirements 3.2 Choice and Design of System 3.3 Division of the Alarm Zone and Detection Zone 3.4 Fire Control Center 4 Automatic Control Design 4.1 General Requirements 4.2 Automatic Control Design of the Automatic Sprinkler System 4.3 Automatic Control Design of Fire Hydrant System 4.4 Automatic Control Design of Gases (Bubble) Fire-extinguishing System 4.5 Automatic Control Design of Smoke Exhaust System 4.6 Automatic Control Design of Fire Door and Fire Roller Shutter System 4.7 Automatic Control Design of Elevator 4.8 Automatic Control Design of the Fire Alarm and Signalling Device 4.9 Automatic Control Design of the Fire Emergency Lighting System 4.10 Automatic Control Design of the Related Equipment 5 Fire Detector Choice 5.1 General Requirements 5.2 Choice of Point Type Fire Detector 5.3 Choice of Line type Fire Detector 5.4 Choice of Aspirating Smoke Detector 6 Setting of the Equipment 6.1 Setting of the Fire Alarm Control Unit and Automatic Control Equipment 6.2 Setting of the Fire Detector 6.3 Setting of the Manual Call Point 6.4 Setting of the Fire Display Panel 6.5 Setting of the Fire Alarm Singalling Device 6.6 Setting of the Sounder Equipment for Fire Emergency Purposes 6.7 Setting of the Fire Telephone 6.8 Setting of the Module 6.9 Setting of the Graph Indicator in Fire Control Center 6.10 Setting of the Routing Equipment 6.11 Setting of the Indicator and Control Unit for Fire Doors 7 Fire Alarm and Safety System Installed in Dwelling Building 7.1 General Requirement 7.2 System Design 7.3 Setting of the Fire Detector 7.4 Setting of the Fire Alarm Control Unit for Household 7.5 Setting of the Fire Alarm Signalling Device 7.6 Setting of the Emergency Broadcast Device 8 Combustible Gas Detection and Alarm System 8.1 General Requirement 8.2 Setting of the Combustible Gas Detector 8.3 Setting of the Combustible Gas Control Unit 9 Alarm and Monitoring System for Electric Fire Protection 9.1 General Requirement 9.2 Setting of the Leakage Current Detector for Electric Fire Prevention 9.3 Setting of the Heat Detector for Electric Fire Prevention 9.4 Setting of the Independent Detector for Electric Fire Prevention 9.5 Setting of the Alarm and Control Unit for Electric Fire Protection 10 Power Supply 10.1 General Requirement 10.2 Ground Connection 11 Wiring 11.1 General Requirement 11.2 Interior Wiring 12 Automatic Fire Alarm System for Typical Place 12.1 The Traffic Tunnel 12.2 The Oil Tank Area 12.3 The Cable Tunnel 12.4 The Large Space Places Where Higher than 12m Appendix A Operating Status Information Table for Fire Alarm & the Fire Equipment in the Building Appendix B Fire Safety Management Information Table Appendix C Classification for the Point Type Heat Detectors Appendix D Specific Setting of the Detectors Appendix E Limit Curve for Install Space of the Detectors Appendix F Setting of Detectors Influenced by Roof Beam Appendix G Number of the Roof Beams Protected by One Detector Based on the Roof Beams Area Explanation of Wording in This Code List of Quoted Standards
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Foryou Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 50116-2013, GB/T 50116-2013, GBT 50116-2013, GB50116-2013, GB 50116, GB50116, GB/T50116-2013, GB/T 50116, GB/T50116, GBT50116-2013, GBT 50116, GBT50116