2023-3-20 3.238.250.73
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB/T 11828.5-2011
GB/T 11828.5-2011   Instruments for stage measurement—Part 5:Electronic gauge (English Version)
Standard No.: GB/T 11828.5-2011 Status:valid remind me the status change

Email:

Language:English File Format:PDF
Word Count: 6000 words Price(USD):180.0 remind me the price change

Email:

Implemented on:2012-6-1 Delivery: via email in 1 business day
,,
Standard No.: GB/T 11828.5-2011
English Name: Instruments for stage measurement—Part 5:Electronic gauge
Chinese Name: 水位测量仪器 第5部分:电子水尺
Chinese Classification: N93    Hydrology and water conservancy instrument
Professional Classification: GB    National Standard
Issued by: AQSIQ,SAC
Issued on: 2011-12-30
Implemented on: 2012-6-1
Status: valid
Language: English
File Format: PDF
Word Count: 6000 words
Price(USD): 180.0
Delivery: via email in 1 business day
1 Scope This part of GB/T 11828 specifies the terms and definitions, classification, technical requirements, test methods, inspection rules, marking, instructions for use, packaging, transportation and storage of the ultrasonic stage gauge. This part is applicable to the ultrasonic stage gauge for measuring the stage of rivers, lakes, reservoirs, channels and other water bodies. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated reference, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 4208 Degrees of protection provided by enclosure (IP code) GB/T 9359 Basic conditions and methods of environmental test for hydrological instrument GB/T 9969 General principles for preparation of instructions for use of industrial products GB/T 17626.5-2008 Electromagnetic compatibility — Testing and measurement techniques — Surge immunity test GB/T 17626.8 Electromagnetic compatibility — Testing and measurement techniques — Power frequency magnetic field immunity test GB/T 18185 Specification of reliability for hydrologic instruments GB/T 18522.2 General specification for hydrometric instruments — Part 2: Referential operating condition GB/T 19677 Essential technical terms and symbols for hydrologic instrument GB/T 19705 Signals and interfaces of hydrometry instruments GB/T 27993 General technical conditions for stage measuring instruments 3 Terms and definitions For the purposes of this document, the terms and definitions given in GB/T 19677 and the following apply. 3.1 ultrasonic stage gauge instrument for measuring the stage by measuring the propagation time utilizing the principle that ultrasonic waves reflect when encountering medium interfaces with different densities 3.1.1 liquid medium ultrasonic stage gauge ultrasonic stage gauge with water body as ultrasonic propagation medium (3.1) 3.1.2 gas medium ultrasonic stage gauge ultrasonic stage gauge with air as ultrasonic propagation medium (3.1) 3.2 acoustic path area effectively covered by ultrasonic waves when they propagate directionally in a medium
Foreword iii 1 Scope 2 Normative references 3 Terms and definitions 4 Classification and structural composition 4.1 Classification 4.2 Structural composition 5 Requirements 5.1 Working environment 5.2 Main technical parameters of equipment 6 Test conditions and methods 6.1 Test conditions 6.2 Test requirements 6.3 Test method 7 Inspection rules 7.1 End-of-manufacturing inspection 7.2 Type inspection 8 Marking and instructions for use 8.1 Marking 8.2 Instructions for use 9 Packaging, transportation and storage 9.1 Packaging 9.2 Transportation 9.3 Storage
Referred in GB/T 11828.5-2011:
*GB/T 4208-2017 Degrees of protection provided by enclosure(IP code)
*GB/T 9359-2016 Basic conditions and methods of environmental test for hydrological instrumet
*GB/T 9969-2008 General Principles for Preparation of Instructions for Use of Industrial Products
*GB/T 17626.5-2008 Electromagnetic compatibility - Testing and measurement techniques - Surge immunity test
*GB/T 17626.8-2006 Electromagnetic compatibility (EMC) - Part 8: Testing and measurement techniques - Power frequency magnetic field immunity test
*GB/T 18185-2014 Specification of reliability for hydrologic instruments
*GB/T 18522.2-2002 General specification for hydrometric instruments--Part 6:Referential operating condition
*GB/T 19677-2005 Essential technical terms and symbols for hydrologic instrument
*GB/T 19705-2017 Signals and interfaces for hydrometry instruments
*GB/T 27993-2011 General technical conditions for stage measuring instruments
Code of China
Standard
GB/T 11828.5-2011  Instruments for stage measurement—Part 5:Electronic gauge (English Version)
Standard No.GB/T 11828.5-2011
Statusvalid
LanguageEnglish
File FormatPDF
Word Count6000 words
Price(USD)180.0
Implemented on2012-6-1
Deliveryvia email in 1 business day
Detail of GB/T 11828.5-2011
Standard No.
GB/T 11828.5-2011
English Name
Instruments for stage measurement—Part 5:Electronic gauge
Chinese Name
水位测量仪器 第5部分:电子水尺
Chinese Classification
N93
Professional Classification
GB
ICS Classification
Issued by
AQSIQ,SAC
Issued on
2011-12-30
Implemented on
2012-6-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
6000 words
Price(USD)
180.0
Keywords
GB/T 11828.5-2011, GB 11828.5-2011, GBT 11828.5-2011, GB/T11828.5-2011, GB/T 11828.5, GB/T11828.5, GB11828.5-2011, GB 11828.5, GB11828.5, GBT11828.5-2011, GBT 11828.5, GBT11828.5
Introduction of GB/T 11828.5-2011
1 Scope This part of GB/T 11828 specifies the terms and definitions, classification, technical requirements, test methods, inspection rules, marking, instructions for use, packaging, transportation and storage of the ultrasonic stage gauge. This part is applicable to the ultrasonic stage gauge for measuring the stage of rivers, lakes, reservoirs, channels and other water bodies. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated reference, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 4208 Degrees of protection provided by enclosure (IP code) GB/T 9359 Basic conditions and methods of environmental test for hydrological instrument GB/T 9969 General principles for preparation of instructions for use of industrial products GB/T 17626.5-2008 Electromagnetic compatibility — Testing and measurement techniques — Surge immunity test GB/T 17626.8 Electromagnetic compatibility — Testing and measurement techniques — Power frequency magnetic field immunity test GB/T 18185 Specification of reliability for hydrologic instruments GB/T 18522.2 General specification for hydrometric instruments — Part 2: Referential operating condition GB/T 19677 Essential technical terms and symbols for hydrologic instrument GB/T 19705 Signals and interfaces of hydrometry instruments GB/T 27993 General technical conditions for stage measuring instruments 3 Terms and definitions For the purposes of this document, the terms and definitions given in GB/T 19677 and the following apply. 3.1 ultrasonic stage gauge instrument for measuring the stage by measuring the propagation time utilizing the principle that ultrasonic waves reflect when encountering medium interfaces with different densities 3.1.1 liquid medium ultrasonic stage gauge ultrasonic stage gauge with water body as ultrasonic propagation medium (3.1) 3.1.2 gas medium ultrasonic stage gauge ultrasonic stage gauge with air as ultrasonic propagation medium (3.1) 3.2 acoustic path area effectively covered by ultrasonic waves when they propagate directionally in a medium
Contents of GB/T 11828.5-2011
Foreword iii 1 Scope 2 Normative references 3 Terms and definitions 4 Classification and structural composition 4.1 Classification 4.2 Structural composition 5 Requirements 5.1 Working environment 5.2 Main technical parameters of equipment 6 Test conditions and methods 6.1 Test conditions 6.2 Test requirements 6.3 Test method 7 Inspection rules 7.1 End-of-manufacturing inspection 7.2 Type inspection 8 Marking and instructions for use 8.1 Marking 8.2 Instructions for use 9 Packaging, transportation and storage 9.1 Packaging 9.2 Transportation 9.3 Storage
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Foryou Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 11828.5-2011, GB 11828.5-2011, GBT 11828.5-2011, GB/T11828.5-2011, GB/T 11828.5, GB/T11828.5, GB11828.5-2011, GB 11828.5, GB11828.5, GBT11828.5-2011, GBT 11828.5, GBT11828.5