GB/T 20716.1-2006 Road vehicles - Connectors for the electrical connection of towing and towed vehicles - Part 1: Connectors for braking systems and running gears of vehicles with 24V nominal supply v (English Version)
Road vehicles - Connectors for the electrical connection of towing and towed vehicles - Part 1: Connectors for braking systems and running gears of vehicles with 24V nominal supply v
1 Scope
This part specifies the dimensions of, and specifies the contact allocation and tests and test requirements for, connectors for the electrical connection of the braking systems and running gear of towing and towed vehicles with 24 V nominal supply voltage. In addition, it specifies a park socket used to receive and store the plug when disconnected.
2 Normative References
The following normative documents contain provisions which, through reference in this text, constitute provisions of this part of GB/T 20716. For dated references, subsequent amendments (excluding corrections), or revisions, of any of these publications do not apply to this part. However parties to agreements based on this part are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below. For undated references, the latest edition of the normative document referred to applies.
GB/T 20717 Road Vehicles — Connectors for the Electrical Connection of Towing and Towed Vehicles — 15-pole Connector for Vehicles with 24V Nominal Supply Voltage (GB/T 20717-2006, ISO 12098:2004, IDT)
GB/T 20716.2 Road Vehicles — Connectors for the Electrical Connection of Towing and Towed Vehicles — Part 2: Connectors for Braking Systems and Running Gears of Vehicles with 12 V Nominal Supply Voltage (GB/T 20716.2-2006, ISO 7638-2:2003, IDT)
GB/T 5053.3 Road Vehicles — Connectors for the Electrical Connection of Towing and Towed Vehicles — Definitions, Tests and Requirements (GB/T 5053.3-2006, ISO 4091:2003, IDT)
ISO 4009 Commercial Vehicles — Location of Electrical and Pneumatic Connections between Towing Vehicles and Trailers
ISO 4141 (all parts) Road Vehicles — Multi-core Connecting Cables
ISO 11992-1 Road Vehicles — Interchange of Digital Information on Electrical Connections between Towing and Towed Vehicles — Part 1: Physical Layer and Data-link Layer
ISO 11992-2 Road Vehicles — Interchange of Digital Information on Electrical Connections between Towing and Towed Vehicles — Part 2: Application Layer for Brakes and Running Gear
3 Terms and Definitions
For the purposes of this part, the terms and definitions given in GB/T 5053.3 apply.
4 Dimensional Characteristics
4.1 General
Details not specified are at the manufacturer’s discretion.
The contacts shall be floating and shall align to the datum position when plug and socket are engaged.
4.2 Plug
Dimensions of the plug shall be in accordance with Figure 1.
The locking lever design shall take into consideration the space required for screws used to fasten the socket (see Figure 2).
4.3 Socket
Dimensions of the socket shall be in accordance with Figure 2.
The cover is shown in the open position: it shall close automatically when the plug is disconnected.
4.4 Park socket
Foreword II
1 Scope
2 Normative References
3 Terms and Definitions
4 Dimensional Characteristics
5 Application of the Connector
6 Tests and Specific Requirements
GB/T 20716.1-2006 Road vehicles - Connectors for the electrical connection of towing and towed vehicles - Part 1: Connectors for braking systems and running gears of vehicles with 24V nominal supply v (English Version)
Standard No.
GB/T 20716.1-2006
Status
valid
Language
English
File Format
PDF
Word Count
3500 words
Price(USD)
80.0
Implemented on
2007-8-1
Delivery
via email in 1 business day
Detail of GB/T 20716.1-2006
Standard No.
GB/T 20716.1-2006
English Name
Road vehicles - Connectors for the electrical connection of towing and towed vehicles - Part 1: Connectors for braking systems and running gears of vehicles with 24V nominal supply v
1 Scope
This part specifies the dimensions of, and specifies the contact allocation and tests and test requirements for, connectors for the electrical connection of the braking systems and running gear of towing and towed vehicles with 24 V nominal supply voltage. In addition, it specifies a park socket used to receive and store the plug when disconnected.
2 Normative References
The following normative documents contain provisions which, through reference in this text, constitute provisions of this part of GB/T 20716. For dated references, subsequent amendments (excluding corrections), or revisions, of any of these publications do not apply to this part. However parties to agreements based on this part are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below. For undated references, the latest edition of the normative document referred to applies.
GB/T 20717 Road Vehicles — Connectors for the Electrical Connection of Towing and Towed Vehicles — 15-pole Connector for Vehicles with 24V Nominal Supply Voltage (GB/T 20717-2006, ISO 12098:2004, IDT)
GB/T 20716.2 Road Vehicles — Connectors for the Electrical Connection of Towing and Towed Vehicles — Part 2: Connectors for Braking Systems and Running Gears of Vehicles with 12 V Nominal Supply Voltage (GB/T 20716.2-2006, ISO 7638-2:2003, IDT)
GB/T 5053.3 Road Vehicles — Connectors for the Electrical Connection of Towing and Towed Vehicles — Definitions, Tests and Requirements (GB/T 5053.3-2006, ISO 4091:2003, IDT)
ISO 4009 Commercial Vehicles — Location of Electrical and Pneumatic Connections between Towing Vehicles and Trailers
ISO 4141 (all parts) Road Vehicles — Multi-core Connecting Cables
ISO 11992-1 Road Vehicles — Interchange of Digital Information on Electrical Connections between Towing and Towed Vehicles — Part 1: Physical Layer and Data-link Layer
ISO 11992-2 Road Vehicles — Interchange of Digital Information on Electrical Connections between Towing and Towed Vehicles — Part 2: Application Layer for Brakes and Running Gear
3 Terms and Definitions
For the purposes of this part, the terms and definitions given in GB/T 5053.3 apply.
4 Dimensional Characteristics
4.1 General
Details not specified are at the manufacturer’s discretion.
The contacts shall be floating and shall align to the datum position when plug and socket are engaged.
4.2 Plug
Dimensions of the plug shall be in accordance with Figure 1.
The locking lever design shall take into consideration the space required for screws used to fasten the socket (see Figure 2).
4.3 Socket
Dimensions of the socket shall be in accordance with Figure 2.
The cover is shown in the open position: it shall close automatically when the plug is disconnected.
4.4 Park socket
Contents of GB/T 20716.1-2006
Foreword II
1 Scope
2 Normative References
3 Terms and Definitions
4 Dimensional Characteristics
5 Application of the Connector
6 Tests and Specific Requirements