2026-9-22 216.73.217.108
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB/T 24293-2026
GB/T 24293-2026   Thermostatic faucet (English)
Standard No.: GB/T 24293-2026 Status:to be valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 13500 words Translation Price(USD):390.0 remind me the price change

Email:

Implemented on:2027-3-1 Delivery: via email in 1~3 business day

→ → →

,,2027-3-1,D341BB55EFEA0F9A1788420236915
Standard No.: GB/T 24293-2026
English Name: Thermostatic faucet
Chinese Name: 恒温水嘴
Professional Classification: GB    National Standard
Source Content Issued by: SAMR, SAC
Issued on: 2026-08-28
Implemented on: 2027-3-1
Status: to be valid
Superseding:GB/T 24293-2009 Digital thermostatic faucet
Target Language: English
File Format: PDF
Word Count: 13500 words
Translation Price(USD): 390.0
Delivery: via email in 1~3 business day
GB/T 24293-2026 Thermostatic faucet English Thermostatic faucet 1 Scope This document specifies the classification, appearance, processing and assembly, dimensions, limits for hazardous substance extraction, and performance requirements for thermostatic faucets (hereinafter referred to as "faucets"), describes the corresponding test methods, and specifies the conditions of use, materials and associated devices, inspection rules as well as marking, packaging, transport and storage. This document applies to the design, production, inspection and sale of faucets that are installed in washrooms (restrooms and bathrooms), kitchens, and other household and similar places of use and whose outlet water temperature is controlled at a preset temperature. 2 Normative references The following documents contain requirements which, through reference in this text, constitute provisions of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 2828.1 Sampling procedures for inspection by attributes - Part 1: Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot inspection GBGB/T 7306.1 Pipe threads with 55 degree thread angle where pressure-tight joints are made on the threads - Part 1: Parallel internal and taper external threads GB/T 7306.2 Pipe threads with 55 degree thread angle where pressure-tight joints are made on the threads - Part 2: Taper internal and external threads GB/T 7307 Pipe threads with 55 degree thread angle where pressure-tight joints are not made on the threads GB/T 23448 Sanitary ware - Flexible hose GB/T 33733 Terminology and classification for the kitchen and sanitary ware fittings GB/T 44180-2024 General technical requirements for kitchen and sanitary ware fittings JC/T 932 Drainage fittings for sanitary wares QB/T 1334-2013 General technical specifications for faucets QB/T 5525 Limits and test methods for hazardous substances extraction in kitchen and sanitary hardware products 3 Terms and definitions For the purpose of this document, the terms and definitions defined in GB/T 33733 and the followings apply. 3.1 electronic faucet faucet that is powered by one or more means including external power supply, battery, or hydroelectric power, and realizes one or more functions such as non-contact control, touch control, voice control, application/application software (APP) remote control and temperature display [Source: QB/T 5003-2024, 3.1] 3.2 safety lock component that restricts the temperature adjustment device from continuing to rotate or move in the direction of increasing temperature Note: When the user needs to continue increasing the temperature, the safety lock can be released, generally by pressing. 4 Classification 4.1 According to the control method, they are classified into mechanical faucet and electronic faucets. 4.2 According to the occasion of use, they are classified into washbasin faucets, kitchen faucets, shower faucets, bathtub faucets and bidet faucets, etc. 4.3 According to the power supply mode, they are classified into AC power supply faucets and DC power supply faucets. 5 Conditions of use Faucets shall function normally under the following conditions: a) Ambient temperature: 1 ℃ ~ 55 ℃; b) Relative ambient humidity (RH): not greater than 93% (at 25 ℃); c) Working pressure: 0.05 MPa ~ 1.0 MPa; if exceeding 0.5 MPa, install a pressure reducing valve; d) Medium service temperature: Cold water temperature 4 ℃ ~ 29 ℃, hot water temperature 45 ℃ ~ 85 ℃. 6 Materials and associated devices 6.1 All materials used in faucets that come into contact with drinking water shall not, under the conditions of use specified in this document, cause harm to human health or cause any changes in the quality, appearance, taste, odor, etc. of drinking water. 6.2 Components of faucets that come into contact with water shall not be made of corrosion-prone materials such as zinc alloy. 6.3 Hoses used with faucets shall comply with the provisions of GB/T 23448. 6.4 Drainage fittings used with faucets shall comply with the provisions of JC/T 932. 7 Requirements 7.1 Appearance 7.1.1 The coating surface shall have uniform gloss and shall be free from defects such as peeling, cracking, scorching, exposed substrate, flaking, black spots, obvious pitting and burrs. 7.1.2 The sprayed surface shall have a fine, dense, smooth texture and uniform color, and shall be free from defects such as sagging, exposed substrate, obvious scratches and dents. 7.1.3 The polished surface shall be smooth and free from obvious defects such as burrs, scratches and dents. 7.1.4 The surface of plastic parts shall be free from obvious defects such as filler spots, ripples, flash, sink marks, warping, weld lines, abrasions, scratches, finishing damage and dirt. 7.1.5 The surface of metal parts shall be free from defects such as corrosion, sand holes, shrinkage cavities, cracks and pores. 7.1.6 The outer surface of the touch panel shall be smooth and free from defects such as scratches, cracks and damage. 7.1.7 Surfaces easily touched by the human body shall be free from defects such as flash, burrs and sharp points. 7.2 Processing and assembly 7.2.1 The external thread surface of the faucet shall be free from obvious defects such as dents and broken threads. The external sealing pipe threads of the faucet shall comply with the provisions of GB/T 7306.1 or GB/T 7306.2. The external non-sealing pipe threads of faucets shall comply with the provisions of GB/T 7307, and the external threads shall not be lower than Class B of GB/T 7307. 7.2.2 The markings on the touch panel shall be concise and easy to understand, and the buttons or touch keys shall be clearly visible. 7.2.3 The cold and hot water inlets and the cold and hot water temperature adjustment shall have clear cold/hot water markings. Cold water shall be indicated by blue, the letter "C" or the word "Cold", and hot water shall be indicated by red, the letter "H" or the word "Hot", or by other easily identifiable markings. Faucets without a temperature display function shall have the reference water temperature marked in the temperature adjustment area.
Contents Foreword 1 Scope 2 Normative references 3 Terms and definitions 4 Classification 5 Conditions of use 6 Materials and associated devices 7 Requirements 8 Test methods 9 Inspection rules 10 Marking, packaging, transport and storage Annex A (Normative) Life test for temperature and/or flow regulating switch Annex B (Normative) Life test for changeover switch Annex C (Normative) Life test for rotating outlet pipe Bibliography
Referred in GB/T 24293-2026:
*GB/T 2828.1-2012 Sampling procedures for inspection by attributea-Part1:Sampling schemes indexed by acceptance quality limit(AQL) for lot-by-lot inspection
*GBGBT7306.1-
*GB/T 7306.2-2000 Pipe threads with 55 degree thread angle where pressure-tight joints are made on the threads--Part 2:Taper internal and external threads
*GB/T 7307-2001 Pipe threads with 55 degree thread angle where pressure-tight joints are not made on the threads
*GB/T 23448-2019 Sanitary ware—Flexible hose
*GB/T 33733-2026 Terminology and classification for the kitchen and sanitary ware fittings
*GB/T 44180-2024 General technical requirements for kitchen and sanitary ware fittings
*JC/T 932-2013 Drainage fittings for sanitary wares
*QB/T 1334-2013 General technical specification for faucets
*QB/T 5525-2020 Limits and test methods for hazardous substances extraction in kitchen and sanitary hardware products
Code of China
Standard
GB/T 24293-2026  Thermostatic faucet (English)
Standard No.GB/T 24293-2026
Statusto be valid
LanguageEnglish
File FormatPDF
Word Count13500 words
Translation Price(USD)390.0
Implemented on2027-3-1
Deliveryvia email in 1~3 business day
Detail of GB/T 24293-2026
Standard No.
GB/T 24293-2026
English Name
Thermostatic faucet
Chinese Name
恒温水嘴
Chinese Classification
Professional Classification
GB
ICS Classification
Issued by
SAMR, SAC
Issued on
2026-08-28
Implemented on
2027-3-1
Status
to be valid
Superseded by
Superseded on
Abolished on
Superseding
GB/T 24293-2009 Digital thermostatic faucet
Language
English
File Format
PDF
Word Count
13500 words
Translation Price(USD)
390.0
Keywords
GB/T 24293-2026, GB 24293-2026, GBT 24293-2026, GB/T24293-2026, GB/T 24293, GB/T24293, GB24293-2026, GB 24293, GB24293, GBT24293-2026, GBT 24293, GBT24293
Introduction of GB/T 24293-2026
GB/T 24293-2026 Thermostatic faucet English Thermostatic faucet 1 Scope This document specifies the classification, appearance, processing and assembly, dimensions, limits for hazardous substance extraction, and performance requirements for thermostatic faucets (hereinafter referred to as "faucets"), describes the corresponding test methods, and specifies the conditions of use, materials and associated devices, inspection rules as well as marking, packaging, transport and storage. This document applies to the design, production, inspection and sale of faucets that are installed in washrooms (restrooms and bathrooms), kitchens, and other household and similar places of use and whose outlet water temperature is controlled at a preset temperature. 2 Normative references The following documents contain requirements which, through reference in this text, constitute provisions of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 2828.1 Sampling procedures for inspection by attributes - Part 1: Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot inspection GBGB/T 7306.1 Pipe threads with 55 degree thread angle where pressure-tight joints are made on the threads - Part 1: Parallel internal and taper external threads GB/T 7306.2 Pipe threads with 55 degree thread angle where pressure-tight joints are made on the threads - Part 2: Taper internal and external threads GB/T 7307 Pipe threads with 55 degree thread angle where pressure-tight joints are not made on the threads GB/T 23448 Sanitary ware - Flexible hose GB/T 33733 Terminology and classification for the kitchen and sanitary ware fittings GB/T 44180-2024 General technical requirements for kitchen and sanitary ware fittings JC/T 932 Drainage fittings for sanitary wares QB/T 1334-2013 General technical specifications for faucets QB/T 5525 Limits and test methods for hazardous substances extraction in kitchen and sanitary hardware products 3 Terms and definitions For the purpose of this document, the terms and definitions defined in GB/T 33733 and the followings apply. 3.1 electronic faucet faucet that is powered by one or more means including external power supply, battery, or hydroelectric power, and realizes one or more functions such as non-contact control, touch control, voice control, application/application software (APP) remote control and temperature display [Source: QB/T 5003-2024, 3.1] 3.2 safety lock component that restricts the temperature adjustment device from continuing to rotate or move in the direction of increasing temperature Note: When the user needs to continue increasing the temperature, the safety lock can be released, generally by pressing. 4 Classification 4.1 According to the control method, they are classified into mechanical faucet and electronic faucets. 4.2 According to the occasion of use, they are classified into washbasin faucets, kitchen faucets, shower faucets, bathtub faucets and bidet faucets, etc. 4.3 According to the power supply mode, they are classified into AC power supply faucets and DC power supply faucets. 5 Conditions of use Faucets shall function normally under the following conditions: a) Ambient temperature: 1 ℃ ~ 55 ℃; b) Relative ambient humidity (RH): not greater than 93% (at 25 ℃); c) Working pressure: 0.05 MPa ~ 1.0 MPa; if exceeding 0.5 MPa, install a pressure reducing valve; d) Medium service temperature: Cold water temperature 4 ℃ ~ 29 ℃, hot water temperature 45 ℃ ~ 85 ℃. 6 Materials and associated devices 6.1 All materials used in faucets that come into contact with drinking water shall not, under the conditions of use specified in this document, cause harm to human health or cause any changes in the quality, appearance, taste, odor, etc. of drinking water. 6.2 Components of faucets that come into contact with water shall not be made of corrosion-prone materials such as zinc alloy. 6.3 Hoses used with faucets shall comply with the provisions of GB/T 23448. 6.4 Drainage fittings used with faucets shall comply with the provisions of JC/T 932. 7 Requirements 7.1 Appearance 7.1.1 The coating surface shall have uniform gloss and shall be free from defects such as peeling, cracking, scorching, exposed substrate, flaking, black spots, obvious pitting and burrs. 7.1.2 The sprayed surface shall have a fine, dense, smooth texture and uniform color, and shall be free from defects such as sagging, exposed substrate, obvious scratches and dents. 7.1.3 The polished surface shall be smooth and free from obvious defects such as burrs, scratches and dents. 7.1.4 The surface of plastic parts shall be free from obvious defects such as filler spots, ripples, flash, sink marks, warping, weld lines, abrasions, scratches, finishing damage and dirt. 7.1.5 The surface of metal parts shall be free from defects such as corrosion, sand holes, shrinkage cavities, cracks and pores. 7.1.6 The outer surface of the touch panel shall be smooth and free from defects such as scratches, cracks and damage. 7.1.7 Surfaces easily touched by the human body shall be free from defects such as flash, burrs and sharp points. 7.2 Processing and assembly 7.2.1 The external thread surface of the faucet shall be free from obvious defects such as dents and broken threads. The external sealing pipe threads of the faucet shall comply with the provisions of GB/T 7306.1 or GB/T 7306.2. The external non-sealing pipe threads of faucets shall comply with the provisions of GB/T 7307, and the external threads shall not be lower than Class B of GB/T 7307. 7.2.2 The markings on the touch panel shall be concise and easy to understand, and the buttons or touch keys shall be clearly visible. 7.2.3 The cold and hot water inlets and the cold and hot water temperature adjustment shall have clear cold/hot water markings. Cold water shall be indicated by blue, the letter "C" or the word "Cold", and hot water shall be indicated by red, the letter "H" or the word "Hot", or by other easily identifiable markings. Faucets without a temperature display function shall have the reference water temperature marked in the temperature adjustment area.
Contents of GB/T 24293-2026
Contents Foreword 1 Scope 2 Normative references 3 Terms and definitions 4 Classification 5 Conditions of use 6 Materials and associated devices 7 Requirements 8 Test methods 9 Inspection rules 10 Marking, packaging, transport and storage Annex A (Normative) Life test for temperature and/or flow regulating switch Annex B (Normative) Life test for changeover switch Annex C (Normative) Life test for rotating outlet pipe Bibliography
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 3680948734
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 24293-2026, GB 24293-2026, GBT 24293-2026, GB/T24293-2026, GB/T 24293, GB/T24293, GB24293-2026, GB 24293, GB24293, GBT24293-2026, GBT 24293, GBT24293