1 Scope
This standard specifies the construction type, site selection, power supply system, charging and battery swap system, monitoring system, carriage way and parking space, civil work, safety and fire protection as well as mark and identification of electric vehicle battery swap station.
This standard is applicable to electric vehicle battery swap station; electric vehicle battery dispatch center may also be implemented by reference to this standard.
2 Normative References
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the normative document (including any amendments) applies.
GB/T 14549 Quality of Electric Energy Supply - Harmonics in Public Supply Network
GB/T 29317 Terminology of Electric Vehicle Charging/Battery Swap Infrastructure
GB 50016 Code of Design on Building Fire Protection and Prevention
GB 50034 Standard for Lighting Design of Buildings
GB 50052 Code for Design Electric Power Supply Systems
GB 50053 Code for Design of 10kV & Under Electric Substation
GB 50054 Code for Design of Low Voltage Electrical Installations
GB 50057 Code for Design Protection of Structures Against Lightning
GB 50140 Code for Design of Extinguisher Distribution in Buildings
DL/T 448 Technical Administrative Code of Electric Energy Metering
DL/T 621 Grounding for AC Electrical Installations
DL/T 814 Function Specification of Distribution Automation Systems
DL 5027 Typical Rules of Fire Protection for Electric Power Installations
NB/T 33001 Specification for Electric Vehicle Off-board Conductive Charger
3 Terms and Definitions
For the purpose of this document, the terms and definitions established in GB/T 29317 apply.
Foreword I
1 Scope
2 Normative References
3 Terms and Definitions
4 Model
5 Requirements
6 Test Method
7 Inspection Rules
8 Marks
Appendix A (Normative) Structural Type of Receptacle1)
1 Scope
This standard specifies the construction type, site selection, power supply system, charging and battery swap system, monitoring system, carriage way and parking space, civil work, safety and fire protection as well as mark and identification of electric vehicle battery swap station.
This standard is applicable to electric vehicle battery swap station; electric vehicle battery dispatch center may also be implemented by reference to this standard.
2 Normative References
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the normative document (including any amendments) applies.
GB/T 14549 Quality of Electric Energy Supply - Harmonics in Public Supply Network
GB/T 29317 Terminology of Electric Vehicle Charging/Battery Swap Infrastructure
GB 50016 Code of Design on Building Fire Protection and Prevention
GB 50034 Standard for Lighting Design of Buildings
GB 50052 Code for Design Electric Power Supply Systems
GB 50053 Code for Design of 10kV & Under Electric Substation
GB 50054 Code for Design of Low Voltage Electrical Installations
GB 50057 Code for Design Protection of Structures Against Lightning
GB 50140 Code for Design of Extinguisher Distribution in Buildings
DL/T 448 Technical Administrative Code of Electric Energy Metering
DL/T 621 Grounding for AC Electrical Installations
DL/T 814 Function Specification of Distribution Automation Systems
DL 5027 Typical Rules of Fire Protection for Electric Power Installations
NB/T 33001 Specification for Electric Vehicle Off-board Conductive Charger
3 Terms and Definitions
For the purpose of this document, the terms and definitions established in GB/T 29317 apply.
Contents of GB/T 26779-2011
Foreword I
1 Scope
2 Normative References
3 Terms and Definitions
4 Model
5 Requirements
6 Test Method
7 Inspection Rules
8 Marks
Appendix A (Normative) Structural Type of Receptacle1)