2025-7-16 18.97.14.87
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB/T 3286.1-2012
GB/T 3286.1-2012   Methods for chemical analysis of limestone and dolomite - Part 1: The determination of calcium oxide and magnesium oxide content - The complexometric titration method and the flame atomic absorption spectrometric method (English Version)
Standard No.: GB/T 3286.1-2012 Status:valid remind me the status change

Email:

Language:English File Format:PDF
Word Count: 8500 words Price(USD):150.0 remind me the price change

Email:

Implemented on:2013-5-1 Delivery: via email in 1 business day
,,
Standard No.: GB/T 3286.1-2012
English Name: Methods for chemical analysis of limestone and dolomite - Part 1: The determination of calcium oxide and magnesium oxide content - The complexometric titration method and the flame atomic absorption spectrometric method
Chinese Name: 石灰石及白云石化学分析方法 第1部分:氧化钙和氧化镁含量的测定 络合滴定法和火焰原子吸收光谱法
Chinese Classification: D52    Metallurgical auxiliary material ore
Professional Classification: GB    National Standard
Issued by: AQSIQ; SAC
Issued on: 2012-11-05
Implemented on: 2013-5-1
Status: valid
Superseding:GB/T 3286.1-1998 Methods for chemical analysis of limestone and dolomite?The determination of calcium oxide and magnesium oxide content
Language: English
File Format: PDF
Word Count: 8500 words
Price(USD): 150.0
Delivery: via email in 1 business day
Foreword Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. GB/T 3286 consists of the following nine parts under the general title Methods for chemical analysis of limestone and dolomite: ——Part 1: The determination of calcium oxide and magnesium oxide content - The complexometric titration method and the flame atomic absorption spectrometric method; ——Part 2: The determination of silicon dioxide content - The silicomolybdic blue spectrophotometric method and the perchloric acid dehydration gravimetric method; ——Part 3: The determination of aluminium oxide content - The chrome azurol S spectrophotometric method and the complexometric titration method; ——Part 4: The determination of iron oxide content - The o-phenanthroline spectrophotometric method and the flame atomic absorption spectrometric method; ——Part 5: The determination of manganese oxide content; ——Part 6: The determination of phosphorus content; ——Part 7: The determination of sulphur content; ——Part 8: The determination of loss on ignition; ——Part 9: The determination of carbon dioxide content. This is Part 1 of GB/T 3286. This part is developed in accordance with the rules given in GB/T 1.1-2009. This part replaces GB/T 3286.1-1998 Methods for chemical analysis of limestone and dolomite - The determination of calcium oxide and magnesium oxide content. The following main changes have been made with respect to GB/T 3286.1-1998: ——the standard name has been changed to Methods for chemical analysis of limestone and dolomite - Part 1: The determination of calcium oxide and magnesium oxide content - The complexometric titration method and the flame atomic absorption spectrometric method; ——the year numbers of normative references have been canceled, and some reference standards have been added; ——the inter-laboratory collaborative test for precision has been carried out, and the "allowable deviation" has been replaced by the statistical repeatability limit r and reproducibility limit R; ——some text expressions have been changed; ——the technical conditions such as dilution ratio of specimen and strontium chloride dosage have been modified. This part was proposed by China Iron and Steel Association. This part is under the jurisdiction of the National Technical Committee on Iron and Steel of Standardization Administration of China (SAC/TC 183). The previous editions of this part are as follows: ——GB/T 3286.1-1982, GB/T 3286.1-1998; ——GB/T 3286.11-1993. Methods for chemical analysis of limestone and dolomite - Part 1: The determination of calcium oxide and magnesium oxide content - The complexometric titration method and the flame atomic absorption spectrometric method WARNING: Persons using this part shall be familiar with normal laboratory practice. This part does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user to establish appropriate safety and health measures and to ensure compliance with any national regulatory conditions. 1 Scope This part of GB/T 3286 specifies the determination of calcium oxide content and magnesium oxide content by complexometric titration method and the determination of magnesium oxide content by atomic absorption spectrometric method. This part is applicable to the determination of calcium oxide content and magnesium oxide content in limestone and dolomite, and also applicable to the determination of calcium oxide content and magnesium oxide content in metallurgical lime. Determination range (mass fraction) in complexometric titration method: calcium oxide content: >20%, magnesium oxide content: >2.5%; determination range (mass fraction) in atomic absorption spectrometric method: magnesium oxide content of 0.1% to 2.5%. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 2007.2 General rules for the sampling and sample preparation of minerals in bulk-Manual method of sample preparation GB/T 3286.2 Methods for chemical analysis of limestone and dolomite - Part 2: The determination of silicon dioxide content - The silicomolybdic blue spectrophotometric method and the perchloric acid dehydration gravimetric method GB/T 3286.3 Methods for chemical analysis of limestone and dolomite - Part 3: The determination of aluminium oxide content - The chrome azurol S spectrophotometric method and the complexometric titration method GB/T 3286.4 Methods for chemical analysis of limestone and dolomite - Part 4: The determination of iron oxide content - The o-phenanthroline spectrophotometric method and the flame atomic absorption spectrometric method GB/T 6379.2 Accuracy (trueness and precision) of measurement methods and results - Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method GB/T 6682 Water for analytical laboratory use - Specification and test methods GB/T 7728 Chemical analysis of metallurgical products - General rule for flame atomic absorption spectrometric methods GB/T 8170 Rules of rounding off for numerical values & expression and judgment of limiting values 3 Complexometric titration method 3.1 Principle Melt down the test portion with mixed flux of sodium carbonate - boric acid, and then leach with diluted hydrochloric acid. Take a part of the test solution, mask the iron, aluminum and manganese ions with triethanolamine, and titrate the calcium oxide with EDTA or EGTA standard volumetric solution in strong alkali medium with calcium carboxylic acid (calcium indicator) as the indicator. For high magnesium specimens, preset 90% to 95% EDTA or EGTA standard volumetric solution before adjusting the test solution to alkaline, so as to eliminate the influence of a large amount of magnesium. Take another part of the test solution, mask the iron, aluminum and manganese ions with triethanolamine, titrate the calcium oxide and magnesium oxide with EDTA standard volumetric solution in ammonia buffer solution with a pH value of 10 and acid chrome blue K and naphthol green B as mixed indicator, or mask the calcium with slightly excessive EGTA standard volumetric solution, and titrate the magnesium oxide with CyDTA standard volumetric solution. The content of iron oxide and aluminum oxide in specimen is greater than 2.0% or the manganese oxide is greater than 0.10%. Precipitate and separate the iron, aluminium and manganese irons with sodium diethylamine dithiocarbamate (copper reagent), take the filtrate, and titrate the calcium oxide and magnesium oxide with EDTA or EGTA and CyDTA standard volumetric solutions. 3.2 Reagents Unless otherwise stated, only recognized analytically pure reagents and distilled water above Grade III specified in GB/T 6682 or water with equivalent purity shall be used. 3.2.1 Mixed flux: grind two portions of anhydrous sodium carbonate and one portion of boric acid, and mix them well. 3.2.2 Hydrochloric acid (1+5). 3.2.3 Triethanolamine (1+4). 3.2.4 Ammonia water (1+1). 3.2.5 Potassium hydroxide solution (200g/L), stored in plastic bottles for more than 12h after being prepared prior to use. 3.2.6 Sodium diethylamine dithiocarbamate (copper reagent) solution (50g/L), prepared immediately before use. 3.2.7 Ammonia buffer solution (pH10): dissolve 67.5g ammonium chloride in water, add 570mL ammonia water (ρ=0.90g/mL), dilute to 1L with water, and mix well. 3.2.8 Calcium indicator (calcium carboxylic acid): grind 1g calcium indicator and 100g sodium chloride, and mix them well. 3.2.9 Acid chrome blue K-naphthol green B mixed indicator solution: dissolve 0.5g acid chrome blue K and 0.2 gnaphthol green B in water and dilute to 70mL with water. Note: The ratio of acid chrome blue K to naphthol green B may be adjusted according to the color sensitivity of the indicator and the color discrimination ability of the operator. 3.2.10 Calcium oxide standard solution: weigh 0.8924g high purity calcium carbonate (with a purity of not less than 99.99%, dry at 105℃ to 110℃ for 1h before weighing and cool to room temperature in a dryer), put it in a 250mL beaker, add about 100mL water, and cover it with a watch glass. Slowly add 10mL hydrochloric acid (1+1) until the reagent dissolves, heat and boil to remove carbon dioxide, then take it down and cool to room temperature. Transfer the solution obtained into a 1,000mL volumetric flask, dilute it to the scale with water and mix well. This solution contains 0.50mg calcium oxide per 1.00mL. 3.2.11 Magnesium oxide standard solution: weigh 0.5000g high purity magnesium oxide (with a purity of not less than 99.99%, burn at 950℃ to 1,000℃ for 1h before weighing and then cool to room temperature in a dryer), put it in a 250mL beaker, add about 100mL water, and cover it with a watch glass. Slowly add 15mL hydrochloric acid (1+1) until the reagent dissolves, heat and boil, then take it down and cool to room temperature. Transfer the solution obtained into a 1,000mL volumetric flask, dilute it to the scale with water and mix well. This solution contains 0.50mg magnesium oxide per 1.00mL. 3.2.12 EDTA standard volumetric solution: [c(EDTA)=0.01mol/L] 3.2.12.1 Preparation Weigh 3.72g EDTA into a 500mL beaker, add about 300mL water, heat at low temperature and stir continuously. After all the reagents are dissolved, cool to room temperature, transfer into a 1,000mL volumetric flask, dilute it to the scale with water and mix well. 3.2.12.2 Calibration of titer of calcium oxide by EDTA standard volumetric solution Transfer three portions of 50.00mL calcium oxide standard solution (3.2.10) into 250mL or 500mL conical flasks respectively, add 2mL magnesium oxide standard solution (3.2.11), 5mL triethanolamine (3.2.3), 20mL potassium hydroxide solution (3.2.5) and about 0.1g calcium indicator (3.2.8), and titrate with EDTA standard volumetric solution (3.2.12.1) while shaking constantly until the solution changes from red to bright blue. The extreme difference of the volumes of EDTA standard volumetric solution consumed for three portions of calcium oxide standard solution shall not exceed 0.05mL, and the mean shall be taken. The titer of calcium oxide by EDTA standard volumetric solution is calculated using Equation (1):
Foreword i 1 Scope 2 Normative references 3 Complexometric titration method 4 Flame atomic absorption spectrometric method 5 Test report Annex A (Normative) Flow chart of procedure for acceptance of specimen analysis results Annex B (Informative) Functional relationship of precision test and original data
Referred in GB/T 3286.1-2012:
*GBT2007.2-
*GB/T 3286.2-2012 Methods for chemical analysis of limestone and dolomite - Part 2: The determination of silicon dioxide content - The silicomolybdic blue spectrophotometric method and the perchloric acid dehydration gravimetric method
*GB/T 3286.3-2012 Methods for chemical analysis of limestone and dolomite - Part 3: The determination of aluminium oxide content - The chrome azurol S spectrophotometric method and the complexometric titration method
*GB/T 3286.4-2012 Methods for chemical analysis of limestone and dolomite - Part 4: The determination of iron oxide content - The o-phenanthroline spectrophotometric method and the flame atomic absorption spectrometric method
*GB/T 6379.2-2004 Accuracy (trueness and precision) ofmeasurement methods and results - Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method
*GB/T 6682-2008 Water for analytical laboratory use - Specification and test methods
*GB/T 7728-2021 Chemical analysis of metallurgical products—General rule for flame atomic absorption spectrometric methods
*GB/T 8170-2008 Rules of rounding off for numerical values & expression and judgement of limiting values
GB/T 3286.1-2012 is referred in:
*GB/T 32151.10-2015 Requirements of the greenhouse gas emissions accounting and reporting―Part 10:Chemical production enterprise
Code of China
Standard
GB/T 3286.1-2012  Methods for chemical analysis of limestone and dolomite - Part 1: The determination of calcium oxide and magnesium oxide content - The complexometric titration method and the flame atomic absorption spectrometric method (English Version)
Standard No.GB/T 3286.1-2012
Statusvalid
LanguageEnglish
File FormatPDF
Word Count8500 words
Price(USD)150.0
Implemented on2013-5-1
Deliveryvia email in 1 business day
Detail of GB/T 3286.1-2012
Standard No.
GB/T 3286.1-2012
English Name
Methods for chemical analysis of limestone and dolomite - Part 1: The determination of calcium oxide and magnesium oxide content - The complexometric titration method and the flame atomic absorption spectrometric method
Chinese Name
石灰石及白云石化学分析方法 第1部分:氧化钙和氧化镁含量的测定 络合滴定法和火焰原子吸收光谱法
Chinese Classification
D52
Professional Classification
GB
ICS Classification
Issued by
AQSIQ; SAC
Issued on
2012-11-05
Implemented on
2013-5-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
GB/T 3286.1-1998 Methods for chemical analysis of limestone and dolomite?The determination of calcium oxide and magnesium oxide content
Language
English
File Format
PDF
Word Count
8500 words
Price(USD)
150.0
Keywords
GB/T 3286.1-2012, GB 3286.1-2012, GBT 3286.1-2012, GB/T3286.1-2012, GB/T 3286.1, GB/T3286.1, GB3286.1-2012, GB 3286.1, GB3286.1, GBT3286.1-2012, GBT 3286.1, GBT3286.1
Introduction of GB/T 3286.1-2012
Foreword Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. GB/T 3286 consists of the following nine parts under the general title Methods for chemical analysis of limestone and dolomite: ——Part 1: The determination of calcium oxide and magnesium oxide content - The complexometric titration method and the flame atomic absorption spectrometric method; ——Part 2: The determination of silicon dioxide content - The silicomolybdic blue spectrophotometric method and the perchloric acid dehydration gravimetric method; ——Part 3: The determination of aluminium oxide content - The chrome azurol S spectrophotometric method and the complexometric titration method; ——Part 4: The determination of iron oxide content - The o-phenanthroline spectrophotometric method and the flame atomic absorption spectrometric method; ——Part 5: The determination of manganese oxide content; ——Part 6: The determination of phosphorus content; ——Part 7: The determination of sulphur content; ——Part 8: The determination of loss on ignition; ——Part 9: The determination of carbon dioxide content. This is Part 1 of GB/T 3286. This part is developed in accordance with the rules given in GB/T 1.1-2009. This part replaces GB/T 3286.1-1998 Methods for chemical analysis of limestone and dolomite - The determination of calcium oxide and magnesium oxide content. The following main changes have been made with respect to GB/T 3286.1-1998: ——the standard name has been changed to Methods for chemical analysis of limestone and dolomite - Part 1: The determination of calcium oxide and magnesium oxide content - The complexometric titration method and the flame atomic absorption spectrometric method; ——the year numbers of normative references have been canceled, and some reference standards have been added; ——the inter-laboratory collaborative test for precision has been carried out, and the "allowable deviation" has been replaced by the statistical repeatability limit r and reproducibility limit R; ——some text expressions have been changed; ——the technical conditions such as dilution ratio of specimen and strontium chloride dosage have been modified. This part was proposed by China Iron and Steel Association. This part is under the jurisdiction of the National Technical Committee on Iron and Steel of Standardization Administration of China (SAC/TC 183). The previous editions of this part are as follows: ——GB/T 3286.1-1982, GB/T 3286.1-1998; ——GB/T 3286.11-1993. Methods for chemical analysis of limestone and dolomite - Part 1: The determination of calcium oxide and magnesium oxide content - The complexometric titration method and the flame atomic absorption spectrometric method WARNING: Persons using this part shall be familiar with normal laboratory practice. This part does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user to establish appropriate safety and health measures and to ensure compliance with any national regulatory conditions. 1 Scope This part of GB/T 3286 specifies the determination of calcium oxide content and magnesium oxide content by complexometric titration method and the determination of magnesium oxide content by atomic absorption spectrometric method. This part is applicable to the determination of calcium oxide content and magnesium oxide content in limestone and dolomite, and also applicable to the determination of calcium oxide content and magnesium oxide content in metallurgical lime. Determination range (mass fraction) in complexometric titration method: calcium oxide content: >20%, magnesium oxide content: >2.5%; determination range (mass fraction) in atomic absorption spectrometric method: magnesium oxide content of 0.1% to 2.5%. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 2007.2 General rules for the sampling and sample preparation of minerals in bulk-Manual method of sample preparation GB/T 3286.2 Methods for chemical analysis of limestone and dolomite - Part 2: The determination of silicon dioxide content - The silicomolybdic blue spectrophotometric method and the perchloric acid dehydration gravimetric method GB/T 3286.3 Methods for chemical analysis of limestone and dolomite - Part 3: The determination of aluminium oxide content - The chrome azurol S spectrophotometric method and the complexometric titration method GB/T 3286.4 Methods for chemical analysis of limestone and dolomite - Part 4: The determination of iron oxide content - The o-phenanthroline spectrophotometric method and the flame atomic absorption spectrometric method GB/T 6379.2 Accuracy (trueness and precision) of measurement methods and results - Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method GB/T 6682 Water for analytical laboratory use - Specification and test methods GB/T 7728 Chemical analysis of metallurgical products - General rule for flame atomic absorption spectrometric methods GB/T 8170 Rules of rounding off for numerical values & expression and judgment of limiting values 3 Complexometric titration method 3.1 Principle Melt down the test portion with mixed flux of sodium carbonate - boric acid, and then leach with diluted hydrochloric acid. Take a part of the test solution, mask the iron, aluminum and manganese ions with triethanolamine, and titrate the calcium oxide with EDTA or EGTA standard volumetric solution in strong alkali medium with calcium carboxylic acid (calcium indicator) as the indicator. For high magnesium specimens, preset 90% to 95% EDTA or EGTA standard volumetric solution before adjusting the test solution to alkaline, so as to eliminate the influence of a large amount of magnesium. Take another part of the test solution, mask the iron, aluminum and manganese ions with triethanolamine, titrate the calcium oxide and magnesium oxide with EDTA standard volumetric solution in ammonia buffer solution with a pH value of 10 and acid chrome blue K and naphthol green B as mixed indicator, or mask the calcium with slightly excessive EGTA standard volumetric solution, and titrate the magnesium oxide with CyDTA standard volumetric solution. The content of iron oxide and aluminum oxide in specimen is greater than 2.0% or the manganese oxide is greater than 0.10%. Precipitate and separate the iron, aluminium and manganese irons with sodium diethylamine dithiocarbamate (copper reagent), take the filtrate, and titrate the calcium oxide and magnesium oxide with EDTA or EGTA and CyDTA standard volumetric solutions. 3.2 Reagents Unless otherwise stated, only recognized analytically pure reagents and distilled water above Grade III specified in GB/T 6682 or water with equivalent purity shall be used. 3.2.1 Mixed flux: grind two portions of anhydrous sodium carbonate and one portion of boric acid, and mix them well. 3.2.2 Hydrochloric acid (1+5). 3.2.3 Triethanolamine (1+4). 3.2.4 Ammonia water (1+1). 3.2.5 Potassium hydroxide solution (200g/L), stored in plastic bottles for more than 12h after being prepared prior to use. 3.2.6 Sodium diethylamine dithiocarbamate (copper reagent) solution (50g/L), prepared immediately before use. 3.2.7 Ammonia buffer solution (pH10): dissolve 67.5g ammonium chloride in water, add 570mL ammonia water (ρ=0.90g/mL), dilute to 1L with water, and mix well. 3.2.8 Calcium indicator (calcium carboxylic acid): grind 1g calcium indicator and 100g sodium chloride, and mix them well. 3.2.9 Acid chrome blue K-naphthol green B mixed indicator solution: dissolve 0.5g acid chrome blue K and 0.2 gnaphthol green B in water and dilute to 70mL with water. Note: The ratio of acid chrome blue K to naphthol green B may be adjusted according to the color sensitivity of the indicator and the color discrimination ability of the operator. 3.2.10 Calcium oxide standard solution: weigh 0.8924g high purity calcium carbonate (with a purity of not less than 99.99%, dry at 105℃ to 110℃ for 1h before weighing and cool to room temperature in a dryer), put it in a 250mL beaker, add about 100mL water, and cover it with a watch glass. Slowly add 10mL hydrochloric acid (1+1) until the reagent dissolves, heat and boil to remove carbon dioxide, then take it down and cool to room temperature. Transfer the solution obtained into a 1,000mL volumetric flask, dilute it to the scale with water and mix well. This solution contains 0.50mg calcium oxide per 1.00mL. 3.2.11 Magnesium oxide standard solution: weigh 0.5000g high purity magnesium oxide (with a purity of not less than 99.99%, burn at 950℃ to 1,000℃ for 1h before weighing and then cool to room temperature in a dryer), put it in a 250mL beaker, add about 100mL water, and cover it with a watch glass. Slowly add 15mL hydrochloric acid (1+1) until the reagent dissolves, heat and boil, then take it down and cool to room temperature. Transfer the solution obtained into a 1,000mL volumetric flask, dilute it to the scale with water and mix well. This solution contains 0.50mg magnesium oxide per 1.00mL. 3.2.12 EDTA standard volumetric solution: [c(EDTA)=0.01mol/L] 3.2.12.1 Preparation Weigh 3.72g EDTA into a 500mL beaker, add about 300mL water, heat at low temperature and stir continuously. After all the reagents are dissolved, cool to room temperature, transfer into a 1,000mL volumetric flask, dilute it to the scale with water and mix well. 3.2.12.2 Calibration of titer of calcium oxide by EDTA standard volumetric solution Transfer three portions of 50.00mL calcium oxide standard solution (3.2.10) into 250mL or 500mL conical flasks respectively, add 2mL magnesium oxide standard solution (3.2.11), 5mL triethanolamine (3.2.3), 20mL potassium hydroxide solution (3.2.5) and about 0.1g calcium indicator (3.2.8), and titrate with EDTA standard volumetric solution (3.2.12.1) while shaking constantly until the solution changes from red to bright blue. The extreme difference of the volumes of EDTA standard volumetric solution consumed for three portions of calcium oxide standard solution shall not exceed 0.05mL, and the mean shall be taken. The titer of calcium oxide by EDTA standard volumetric solution is calculated using Equation (1):
Contents of GB/T 3286.1-2012
Foreword i 1 Scope 2 Normative references 3 Complexometric titration method 4 Flame atomic absorption spectrometric method 5 Test report Annex A (Normative) Flow chart of procedure for acceptance of specimen analysis results Annex B (Informative) Functional relationship of precision test and original data
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: TransForyou Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 3286.1-2012, GB 3286.1-2012, GBT 3286.1-2012, GB/T3286.1-2012, GB/T 3286.1, GB/T3286.1, GB3286.1-2012, GB 3286.1, GB3286.1, GBT3286.1-2012, GBT 3286.1, GBT3286.1