GB/T 43626-2023 LEDsi lamps for general lighting services with supply voltages not exceeding 50 V a.c. r.m.s. or 120 V ripple free d.c.—Safety specifications (English Version)
LEDsi lamps for general lighting services with supply voltages not exceeding 50 V a.c. r.m.s. or 120 V ripple free d.c. - Safety specifications
1 Scope
This document specifies the safety and interchangeability requirements, together with the test methods and conditions, required to show compliance of LED lamps with integrated means for stable operation, intended for domestic and similar general lighting purposes.
The scope of application is as follows:
——a rated power up to 60 W
——a rated voltage equal to or less than 50 V a.c. r.m.s. or equal or less 120 V ripple free d.c.,
——caps according to Table 1.
Note 1: The value of 60 W rated power is under consideration. Heat management may require lower power.
This document shall be used for products in conjunction with ELV lighting installations.
With reference to IEC 60364-7-715, in ELV lighting installations only SELV sources are applied. Where bare conductors are used, the maximum lamp voltage shall be 25 V a.c. or
60 V d.c.
The requirements of this standard relate only to type testing.
For lamps > 25 V a.c. or 60 V d.c., recommendations for whole production testing or batch
testing are given in GB/T 7000.1-2023 Table Q.1, column class III luminaire, column 4 or 5.
Note 2: Where in this standard the term “lamp(s)” is used, it is understood to stand for semi-integrated LED lamp(s) with supply voltages as in the scope above, except where it is obviously assigned to other types of lamps.
An overview of systems composed of LED modules, lamps and controlgear is given in IEC 62504. Supply voltage does not mean necessarily mains voltage, e.g. 220 V / 50 Hz. A semi-integrated LED lamp can also be driven on a supply voltage with 12 V a.c. or d.c. The control unit in the controlgear in a semi-integrated LED lamp then provides the conversion of 12 V a.c. or d.c. to a special current and voltage to power the LED inside the semi-integrated LED lamp. Schematically, the types of LEDni and LEDsi lamps are shown in Figure 1.
Figure 1 - Types of LED lamps with supply voltage ≤ 50V
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
GB/T 7000.1-2023 Luminaires - Part 1: General requirements and tests (IEC 60598-1:2020, MOD)
Note: There is no technical difference between the referenced content of GB/T 7000.1-2023 and the referenced content of IEC 60598-1:2017.
GB/Z 39942-2021 Application of GB/T 20145 for the assessment of blue light hazard to light sources and luminaires (IEC TR 62778:2014, IDT)
IEC 60061-1 Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 1: Lamp caps
Note: GB/T 1406.1-2008, Types and dimensions of lamp caps - Part 1:Screw caps (IEC 60061-1:2005, MOD)
GB/T 1406.2-2008, Types and dimensions of lamp caps - Part 2: Pin lamp caps (IEC 60061-1:2005, MOD)
GB/T 1406.3-2008, Types and dimensions of lamp caps - Part 3: Prefocus caps (IEC 60061-1:2018, MOD)
GB/T 1406.4-2008, Types and dimensions of lamp caps - Part 4: Miscellaneous caps (IEC 60061-1:2005, MOD)
GB/T 1406.5-2008, Types and dimensions of lamp caps - Part 5: Bayonet caps (IEC 60061-1:2005, MOD)
IEC 60061-3 Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 3: Gauges
Note: GB/T 1483.1-2008, Gauges for lamp caps and holders - Part 1: Gauges for screw caps and holders (IEC 60061-3:2004, MOD)
GB/T 1483.2-2008, Gauges for caps and lampholders - Part 2: Gauges for pin caps and lampholders (IEC 60061-3:2004, MOD)
GB/T 1483.3-2008, Gauges for lamp caps and lampholders - Part 3: Gauges for prefocus caps and lampholders (IEC 60061-3:2004, MOD)
GB/T 1483.4-2009, Gauges for lamp caps and lampholders - Part 4: Gauges for miscellaneous caps and lampholders (IEC 60061-3:2004, MOD)
GB/T 1483.5-2008, Gauges for lamp caps and holders - Part 5: Gauges for bayonet caps and lampholders (IEC 60061-3: 2004, MOD)
IEC 60364-4-41 Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock
Note: GB/T 16895.21-2020, Low-voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock (IEC 60364-4-41:2017, IDT)
IEC 60364-7-715 Low-voltage electrical installations – Part 7-715: Requirements for special installations or locations - Extra-low-voltage lighting installations
Note: GB/T 16895.30-2008, Electrical installations of buildings - Part 7-715: Requirements for special installations or locations - Extra-low-voltage lighting installations (IEC 60364-7-715:1999, IDT)
IEC 60417 Graphical symbols for use on equipment
IEC 60598-1 Luminaires - Part 1: General requirements and tests
Note: GB/T 7000.1-2023, Luminaires - Part 1: General requirements and tests (IEC 60598-1:2020, MOD)
IEC 61347-1 Lamp controlgear - Part 1: General and safety requirements
Note: GB/T 19510.1-2023, Controlgear for electric light sources - Part 1: General and safety requirements (IEC 61347-1:2017, MOD)
IEC 62031 LED modules for general lighting - Safety specifications
Note: GB/T 24819-2023, LED modules for general lighting - Safety specifications (IEC 62031:2018, IDT)
IEC 62504 General lighting - Light emitting diode (LED) products and related equipment – Terms and definitions
Note: GB/T 24826-2016, General lighting - Light emitting diode (LED) products and related equipment - Terms and definitions (IEC 62504:2014, IDT)
IEC 62560 Self-ballasted LED-lamps for general lighting services by voltage > 50 V - Safety specifications
Note: GB/T 24906-2023, Self-ballasted LED-lamps for general lighting services by voltage > 50 V - Safety specifications (ISO 8044:2020, IDT)
3 Terms and definitions
For the purposes of this document the terms and definitions of IEC 62031 , IEC 62504,
IEC 62560 and IEC 61347-1 as well as the following apply.
3.1
ultraviolet hazard efficacy of luminous radiation
KS,v
quotient of a ultraviolet hazard quantity to the corresponding photometric quantity
Note 1: Ultraviolet hazard efficacy of luminous radiation is expressed in mW/klm.
Note 2: The ultraviolet hazard efficacy of luminous radiation is obtained by weighting the spectral power distribution of the lamp with the UV hazard function SUV (λ). Information about the relevant UV hazard function is given in IEC 62471. It only relates to possible hazards regarding UV exposure of human beings. It does not deal with the possible influence of optical radiation on materials, such as mechanical damage or discoloration.
4 General requirement and general test requirements
The requirements of IEC 62560 apply.
5 Marking
The requirements of IEC 62560 apply.
Deviating from the frequency marking in IEC 62560, 5.1 d), the following applies.
If a lamp is only suitable for DC, it shall be marked "DC" or "—" (IEC 60417-5031).
If a lamp is only suitable for AC electronic, it shall be marked “AC electronic” or “~electronic” (IEC 60417-5032).
If a lamp is only suitable for AC 50 Hz/60 Hz, it shall be marked “AC 50 Hz/60 Hz” or “~50 Hz/60 Hz".
If a lamp is suitable for AC electronic and AC 50 Hz/60 Hz, it shall be marked “AC”; the addition “electronic and 50 Hz/60 Hz” is optional.
If a lamp is suitable for DC, AC electronic and AC 50 Hz/60 Hz, it shall only be marked with the voltage, not with the frequency.
Lamps with bulbs not suitable for water contact shall be marked with the symbol according to Figure 2. The marking shall be provided on the packaging or accompanying information. The height of the graphical symbol shall be at least 5 mm. The symbol is not needed if a written cautionary notice is provided.
GB/T 43626-2023 LEDsi lamps for general lighting services with supply voltages not exceeding 50 V a.c. r.m.s. or 120 V ripple free d.c.—Safety specifications (English Version)
Standard No.
GB/T 43626-2023
Status
to be valid
Language
English
File Format
PDF
Word Count
9000 words
Price(USD)
270.0
Implemented on
2026-1-1
Delivery
via email in 1~3 business day
Detail of GB/T 43626-2023
Standard No.
GB/T 43626-2023
English Name
LEDsi lamps for general lighting services with supply voltages not exceeding 50 V a.c. r.m.s. or 120 V ripple free d.c.—Safety specifications
LEDsi lamps for general lighting services with supply voltages not exceeding 50 V a.c. r.m.s. or 120 V ripple free d.c. - Safety specifications
1 Scope
This document specifies the safety and interchangeability requirements, together with the test methods and conditions, required to show compliance of LED lamps with integrated means for stable operation, intended for domestic and similar general lighting purposes.
The scope of application is as follows:
——a rated power up to 60 W
——a rated voltage equal to or less than 50 V a.c. r.m.s. or equal or less 120 V ripple free d.c.,
——caps according to Table 1.
Note 1: The value of 60 W rated power is under consideration. Heat management may require lower power.
This document shall be used for products in conjunction with ELV lighting installations.
With reference to IEC 60364-7-715, in ELV lighting installations only SELV sources are applied. Where bare conductors are used, the maximum lamp voltage shall be 25 V a.c. or
60 V d.c.
The requirements of this standard relate only to type testing.
For lamps > 25 V a.c. or 60 V d.c., recommendations for whole production testing or batch
testing are given in GB/T 7000.1-2023 Table Q.1, column class III luminaire, column 4 or 5.
Note 2: Where in this standard the term “lamp(s)” is used, it is understood to stand for semi-integrated LED lamp(s) with supply voltages as in the scope above, except where it is obviously assigned to other types of lamps.
An overview of systems composed of LED modules, lamps and controlgear is given in IEC 62504. Supply voltage does not mean necessarily mains voltage, e.g. 220 V / 50 Hz. A semi-integrated LED lamp can also be driven on a supply voltage with 12 V a.c. or d.c. The control unit in the controlgear in a semi-integrated LED lamp then provides the conversion of 12 V a.c. or d.c. to a special current and voltage to power the LED inside the semi-integrated LED lamp. Schematically, the types of LEDni and LEDsi lamps are shown in Figure 1.
Figure 1 - Types of LED lamps with supply voltage ≤ 50V
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
GB/T 7000.1-2023 Luminaires - Part 1: General requirements and tests (IEC 60598-1:2020, MOD)
Note: There is no technical difference between the referenced content of GB/T 7000.1-2023 and the referenced content of IEC 60598-1:2017.
GB/Z 39942-2021 Application of GB/T 20145 for the assessment of blue light hazard to light sources and luminaires (IEC TR 62778:2014, IDT)
IEC 60061-1 Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 1: Lamp caps
Note: GB/T 1406.1-2008, Types and dimensions of lamp caps - Part 1:Screw caps (IEC 60061-1:2005, MOD)
GB/T 1406.2-2008, Types and dimensions of lamp caps - Part 2: Pin lamp caps (IEC 60061-1:2005, MOD)
GB/T 1406.3-2008, Types and dimensions of lamp caps - Part 3: Prefocus caps (IEC 60061-1:2018, MOD)
GB/T 1406.4-2008, Types and dimensions of lamp caps - Part 4: Miscellaneous caps (IEC 60061-1:2005, MOD)
GB/T 1406.5-2008, Types and dimensions of lamp caps - Part 5: Bayonet caps (IEC 60061-1:2005, MOD)
IEC 60061-3 Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 3: Gauges
Note: GB/T 1483.1-2008, Gauges for lamp caps and holders - Part 1: Gauges for screw caps and holders (IEC 60061-3:2004, MOD)
GB/T 1483.2-2008, Gauges for caps and lampholders - Part 2: Gauges for pin caps and lampholders (IEC 60061-3:2004, MOD)
GB/T 1483.3-2008, Gauges for lamp caps and lampholders - Part 3: Gauges for prefocus caps and lampholders (IEC 60061-3:2004, MOD)
GB/T 1483.4-2009, Gauges for lamp caps and lampholders - Part 4: Gauges for miscellaneous caps and lampholders (IEC 60061-3:2004, MOD)
GB/T 1483.5-2008, Gauges for lamp caps and holders - Part 5: Gauges for bayonet caps and lampholders (IEC 60061-3: 2004, MOD)
IEC 60364-4-41 Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock
Note: GB/T 16895.21-2020, Low-voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock (IEC 60364-4-41:2017, IDT)
IEC 60364-7-715 Low-voltage electrical installations – Part 7-715: Requirements for special installations or locations - Extra-low-voltage lighting installations
Note: GB/T 16895.30-2008, Electrical installations of buildings - Part 7-715: Requirements for special installations or locations - Extra-low-voltage lighting installations (IEC 60364-7-715:1999, IDT)
IEC 60417 Graphical symbols for use on equipment
IEC 60598-1 Luminaires - Part 1: General requirements and tests
Note: GB/T 7000.1-2023, Luminaires - Part 1: General requirements and tests (IEC 60598-1:2020, MOD)
IEC 61347-1 Lamp controlgear - Part 1: General and safety requirements
Note: GB/T 19510.1-2023, Controlgear for electric light sources - Part 1: General and safety requirements (IEC 61347-1:2017, MOD)
IEC 62031 LED modules for general lighting - Safety specifications
Note: GB/T 24819-2023, LED modules for general lighting - Safety specifications (IEC 62031:2018, IDT)
IEC 62504 General lighting - Light emitting diode (LED) products and related equipment – Terms and definitions
Note: GB/T 24826-2016, General lighting - Light emitting diode (LED) products and related equipment - Terms and definitions (IEC 62504:2014, IDT)
IEC 62560 Self-ballasted LED-lamps for general lighting services by voltage > 50 V - Safety specifications
Note: GB/T 24906-2023, Self-ballasted LED-lamps for general lighting services by voltage > 50 V - Safety specifications (ISO 8044:2020, IDT)
3 Terms and definitions
For the purposes of this document the terms and definitions of IEC 62031 , IEC 62504,
IEC 62560 and IEC 61347-1 as well as the following apply.
3.1
ultraviolet hazard efficacy of luminous radiation
KS,v
quotient of a ultraviolet hazard quantity to the corresponding photometric quantity
Note 1: Ultraviolet hazard efficacy of luminous radiation is expressed in mW/klm.
Note 2: The ultraviolet hazard efficacy of luminous radiation is obtained by weighting the spectral power distribution of the lamp with the UV hazard function SUV (λ). Information about the relevant UV hazard function is given in IEC 62471. It only relates to possible hazards regarding UV exposure of human beings. It does not deal with the possible influence of optical radiation on materials, such as mechanical damage or discoloration.
4 General requirement and general test requirements
The requirements of IEC 62560 apply.
5 Marking
The requirements of IEC 62560 apply.
Deviating from the frequency marking in IEC 62560, 5.1 d), the following applies.
If a lamp is only suitable for DC, it shall be marked "DC" or "—" (IEC 60417-5031).
If a lamp is only suitable for AC electronic, it shall be marked “AC electronic” or “~electronic” (IEC 60417-5032).
If a lamp is only suitable for AC 50 Hz/60 Hz, it shall be marked “AC 50 Hz/60 Hz” or “~50 Hz/60 Hz".
If a lamp is suitable for AC electronic and AC 50 Hz/60 Hz, it shall be marked “AC”; the addition “electronic and 50 Hz/60 Hz” is optional.
If a lamp is suitable for DC, AC electronic and AC 50 Hz/60 Hz, it shall only be marked with the voltage, not with the frequency.
Lamps with bulbs not suitable for water contact shall be marked with the symbol according to Figure 2. The marking shall be provided on the packaging or accompanying information. The height of the graphical symbol shall be at least 5 mm. The symbol is not needed if a written cautionary notice is provided.