2023-3-31 3.238.250.73
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB/T 5013.2-2008
GB/T 5013.2-2008   Rubber insulated cables of rated voltages up to and including 450/750V—Part 2:Test methods (English Version)
Standard No.: GB/T 5013.2-2008 Status:valid remind me the status change

Email:

Language:English File Format:PDF
Word Count: 6000 words Price(USD):120.0 remind me the price change

Email:

Implemented on:2008-9-1 Delivery: via email in 1 business day
,,
Standard No.: GB/T 5013.2-2008
English Name: Rubber insulated cables of rated voltages up to and including 450/750V—Part 2:Test methods
Chinese Name: 额定电压450/750V及以下橡皮绝缘电缆 第2部分:试验方法
Chinese Classification: K13    Cable and its accessory
Professional Classification: GB    National Standard
ICS Classification: 29.060.20 29.060.20    Cables 29.060.20
Issued by: AQSIQ, SAC
Issued on: 2008-01-22
Implemented on: 2008-9-1
Status: valid
Superseding:GB 5013.2-1997 Rubber insulated cables of rated voltages up to and including 450/750V Part 2:Test methods
Language: English
File Format: PDF
Word Count: 6000 words
Price(USD): 120.0
Delivery: via email in 1 business day
1 General 1.1 Scope This Part of GB/T 5013 gives the test methods specified in all parts of GB/T 5013 as far as not laid down in GB/T 2951. 1.2 Normative references The following normative documents contain provisions which, through reference in this text, constitute provisions of this Part of GB/T 5013. At the time of publication, the editions indicated were valid. All normative documents are subject to revision and parties to agreements based on this Part are encouraged to investigate the possibility of applying the most recent editions of the normative documents listed below. GB/T 131 Technical drawings — Method of indicating surface texture (GB/T 131-2006, ISO 1302:1992, IDT) GB/T 2951.1-1997 Common test methods for insulating and sheathing materials of electric cables — Part 1: Methods for general application — Section 1: Measurement of thickness and overall dimensions — Tests for determining the mechanical properties (idt IEC 60811-1-1:1993) GB/T 2951.2-1997 Common test methods for insulating and sheathing materials of electric cables — Part 1: Methods for general application — Section 2: Thermal ageing methods (idt IEC 60811-1-2:1985) GB/T 5013.1-2008 Rubber insulated cables — Rated voltages up to and including 450/750 V — Part 1: General requirements (IEC 60245-1:2003, IDT) GB/T 5013.3 Rubber insulated cables — Rated voltages up to and including 450/750 V — Part 3: Heat resistant silicone insulated cables (GB/T 5013.3-2008, IEC 60245-3:1994, IDT) GB/T 5013.4-2008 Rubber insulated cables — Rated voltages up to and including 450/750 V — Part 4: Cords and flexible cables (IEC 60245-4:2004, IDT) GB/T 5013.8-2006 Rubber insulated cables — Rated voltages up to and including 450/750 V — Part 8: Cords for applications requiring high flexibility (IEC 60245-8:1998, IDT) GB/T 18380.1 Tests on electric cables under fire conditions — Part 1: Test on a single vertical insulated wire or cable (GB/T 18380.1-2001, IEC 60332-1:1993, IDT) 1.3 Classification of tests according to the frequency with which they are carried out The tests specified are type tests (symbol T) and/or sample tests (symbol S) as defined in 2.2 of GB/T 5013.1-2008. The symbols T and S are used in the relevant tables of the particular specifications (GB/T 5013.3, GB/T 5013.4, etc.). 1.4 Sampling If a marking is in relief in insulation or sheath the samples used for the tests shall be taken so as to include such marking. For multicore cables, except for the test specified in 1.9, not more than three cores (of different colours, if applicable) shall be tested unless otherwise specified. 1.5 Pre-conditioning All the tests shall be carried out not less than 16 h after the vulcanization of the insulating or sheathing compounds. 1.6 Test temperature
Referred in GB/T 5013.2-2008:
* GB/T 131-2006 Geometrical Product Specifications (GPS) - Indication of surface texture in technical Product documentation
* GB/T 2951.1-1997 Common test methods for insulating and sheating materials of electric cables Part 1:Methods for general application Section one:Measurement of thickness and overall dimensions―Tests for determining the mechanical properties
* GB/T 2951.2-1997 Common test methods for insulating and sheating materials of electric cables--Part 1: Methods for general application--Section two: Thermal ageing methods
* GB/T 5013.1-2008 Rubber insulated cables of rated voltages up to and including 450/750 V - Part 1:General requiremnts
* GB/T 5013.3-2008 Rubber insulated cables of rated voltages up to and including 450/750V - Part 3: Heat resistant silicone insulated cables
* GB/T 5013.4-2008 Rubber insulated cables of rated voltages up to and including 450/750V - Part 4: Cords and flexible cables
* GB/T 5013.8-2006 Rubber insulated cables of rated voltages up to and including 450/750V Part 8: Cords for applications requiring high flexibility
* GB/T 18380.1-2001 Tests on electric cables under fire conditions-Part 1:Test on a single vertical insulated wire or cable
GB/T 5013.2-2008 is referred in:
* GB/T 5013.1-2008 Rubber insulated cables of rated voltages up to and including 450/750 V - Part 1:General requiremnts
*CQC 1104-2015 Technical Specification for Cables of Electric Vehicles Conductive Charging Systems Part 2: Cables for AC Charging Systems
*CQC 1103-2015 Technical Specification for Cables of Electric Vehicles Conductive Charging Systems Part 1: General Requiremen
Code of China
Standard
GB/T 5013.2-2008  Rubber insulated cables of rated voltages up to and including 450/750V—Part 2:Test methods (English Version)
Standard No.GB/T 5013.2-2008
Statusvalid
LanguageEnglish
File FormatPDF
Word Count6000 words
Price(USD)120.0
Implemented on2008-9-1
Deliveryvia email in 1 business day
Detail of GB/T 5013.2-2008
Standard No.
GB/T 5013.2-2008
English Name
Rubber insulated cables of rated voltages up to and including 450/750V—Part 2:Test methods
Chinese Name
额定电压450/750V及以下橡皮绝缘电缆 第2部分:试验方法
Chinese Classification
K13
Professional Classification
GB
ICS Classification
Issued by
AQSIQ, SAC
Issued on
2008-01-22
Implemented on
2008-9-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
GB 5013.2-1997 Rubber insulated cables of rated voltages up to and including 450/750V Part 2:Test methods
Language
English
File Format
PDF
Word Count
6000 words
Price(USD)
120.0
Keywords
GB/T 5013.2-2008, GB 5013.2-2008, GBT 5013.2-2008, GB/T5013.2-2008, GB/T 5013.2, GB/T5013.2, GB5013.2-2008, GB 5013.2, GB5013.2, GBT5013.2-2008, GBT 5013.2, GBT5013.2
Introduction of GB/T 5013.2-2008
1 General 1.1 Scope This Part of GB/T 5013 gives the test methods specified in all parts of GB/T 5013 as far as not laid down in GB/T 2951. 1.2 Normative references The following normative documents contain provisions which, through reference in this text, constitute provisions of this Part of GB/T 5013. At the time of publication, the editions indicated were valid. All normative documents are subject to revision and parties to agreements based on this Part are encouraged to investigate the possibility of applying the most recent editions of the normative documents listed below. GB/T 131 Technical drawings — Method of indicating surface texture (GB/T 131-2006, ISO 1302:1992, IDT) GB/T 2951.1-1997 Common test methods for insulating and sheathing materials of electric cables — Part 1: Methods for general application — Section 1: Measurement of thickness and overall dimensions — Tests for determining the mechanical properties (idt IEC 60811-1-1:1993) GB/T 2951.2-1997 Common test methods for insulating and sheathing materials of electric cables — Part 1: Methods for general application — Section 2: Thermal ageing methods (idt IEC 60811-1-2:1985) GB/T 5013.1-2008 Rubber insulated cables — Rated voltages up to and including 450/750 V — Part 1: General requirements (IEC 60245-1:2003, IDT) GB/T 5013.3 Rubber insulated cables — Rated voltages up to and including 450/750 V — Part 3: Heat resistant silicone insulated cables (GB/T 5013.3-2008, IEC 60245-3:1994, IDT) GB/T 5013.4-2008 Rubber insulated cables — Rated voltages up to and including 450/750 V — Part 4: Cords and flexible cables (IEC 60245-4:2004, IDT) GB/T 5013.8-2006 Rubber insulated cables — Rated voltages up to and including 450/750 V — Part 8: Cords for applications requiring high flexibility (IEC 60245-8:1998, IDT) GB/T 18380.1 Tests on electric cables under fire conditions — Part 1: Test on a single vertical insulated wire or cable (GB/T 18380.1-2001, IEC 60332-1:1993, IDT) 1.3 Classification of tests according to the frequency with which they are carried out The tests specified are type tests (symbol T) and/or sample tests (symbol S) as defined in 2.2 of GB/T 5013.1-2008. The symbols T and S are used in the relevant tables of the particular specifications (GB/T 5013.3, GB/T 5013.4, etc.). 1.4 Sampling If a marking is in relief in insulation or sheath the samples used for the tests shall be taken so as to include such marking. For multicore cables, except for the test specified in 1.9, not more than three cores (of different colours, if applicable) shall be tested unless otherwise specified. 1.5 Pre-conditioning All the tests shall be carried out not less than 16 h after the vulcanization of the insulating or sheathing compounds. 1.6 Test temperature
Contents of GB/T 5013.2-2008
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Foryou Tech Co., Ltd. 2008-2040
 
 
Keywords: