CQC 1104-2015 Technical Specification for Cables of Electric Vehicles Conductive Charging Systems Part 2: Cables for AC Charging Systems (English Version)
This specification is drafted in accordance with GB/T 1.1-2009.
"Technical Specification for Cables of Electric Vehicles Conductive Charging Systems" series was proposed by China Quality Certification Center. It is one of technical specifications for voluntary certification of products. This series consists of the following 3 technical specifications:
CQC 1103 "Technical Specification for Cables of Electric Vehicles Conductive Charging Systems — Part 1: General Requirement"
CQC 1104 Technical Specification for Cables of Electric Vehicles Conductive Charging Systems — Part 2: Cables for AC Charging Systems
CQC 1105 Technical Specification for Cables of Electric Vehicles Conductive Charging Systems — Part 3: Cables for DC Charging Systems
This specification is the converted and updated version of three standard series: CQC1103-2014, CQC1104-2014, CQC1105-2014, TICW 18-2012 and K175-2014.
Compared with CQC1103~5-2014, except editorial changes, the main technical changes of this specification are as follows:
1. Expression method of product type and specification is revised;
2. Products of halogen-free and cross linking material series are added;
3. EV-VV, EV-S90S90, EV-YJYJ and other series products and relevant requirements are deleted;
4. Temperature grade and the requirements of tear resistance test of TPE sheath are revised;
5. The voltage of voltage test of finished cable was changed to 3500 V; specific voltage test method is specified;
6. Vehicle rolling compaction test, oil resistance test and capacitance increase rate after water penetration are deleted;
7. Extrusion test, reagent resistance test, abrasion resistance test, heat shrinkage test, insulation and long-term DC resistance test and hardness, weather resistance and saponification tests are newly added;
8. The insulation and sheath thickness of the product is adjusted, and the upper and lower limit requirements for outside diameter are deleted;
Chief drafting organizations of this specification:
China Quality Certification Center, National Quality Supervision and Testing Center for Cables and Wires, and DEKRA Certification B. V.
Cheif drafting staff of this specification:
Xie Zhiguo, Huang Xuan, Guan Lili, Li Na, Yang Juanjuan, Xiao Jidong, Zhu Yonghua, Wu Changshun, Hong Jian and Liu Weihai
Chief participating drafting organizations and drafting staff of this specification:
Wuxi Xinhongye Wire & Cable Co., Ltd. Guan Yong
Guangdong OMG Transmitting Technology Co., Ltd. Liu Yaoxun
Zhongli Science And Technology Group Co., Ltd. Sun Jianyu
Hengyang Hengfei Cable Co., Ltd. Wang Fushan
Jiangyin Seven-star Cable Co., Ltd. Gao Wei
Zhongtian Technology Instrument Cable Co., Ltd. Chen Shuai
Wuxi Mingzhu Cable Co., Ltd. Yu Jinhua
Technical Specification for Cables of Electric Vehicles Conductive Charging Systems
Part 2: Cables for AC Charging Systems
1 Scope
This specification specifies structure, size and test requirements of cables for AC conductive charging systems of electric vehicles of rated voltages up to and including 450/750V.
Cables included in this specification are applicable to the connection between electric vehicles and charging spot of low speed electric vehicle charging station, and applicable to the connection between portable charging equipment and charge power supply.
2 Normative References
The following normative documents contain provisions which, through reference in this text, constitute provisions of this specification. The following documents are indispensable for the application of this document. For dated references, only the dated editions apply. For undated references, the latest editions (including any amendments) apply.
GB/T 2900.10 Electrotechnical Vocabulary — Electric Cables
GB/T 2951.11-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables — Part 11: Methods for General Application — Measurement of Thickness and Overall Dimensions — Tests for Determining the Mechanical Properties (IEC 60811-1-1:2001)
GB/T 2951.12-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables — Part 12: Methods for General Application — Thermal Ageing Methods (IEC 60811-1-2:1985)
GB/T 2951.13-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables — Part 13: Methods for General Application — Measurement for Determining the Density — Water Absorption Tests — Shrinkage Test (IEC 60811-1-3:2001)
GB/T 2951.14-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables — Part 14: Methods for General Application — Test at Low Temperature (IEC 60811-1-4:1985)
GB/T 2951.21-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables — Part 21: Methods Specific to Elastomeric Compounds — Ozone Resistance, Hot Set and Mineral Oil Immersion Tests (IEC 60811-2-1:2001)
GB/T 2951.31-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables — Part 31: Methods Specific to PVC Compounds — Pressure Test at High Temperature — Test for Resistance to Cracking (IEC 60811-3-1:1985)
GB/T 3048.4-2007 Test Methods for Electrical Properties of Electric Cables and Wires — Part 4: Test of DC Resistance of Conductors
GB/T 3048.8-2007 Test Methods for Electrical Properties of Electric Cables and Wires — Part 8: AC Voltage Test
GB/T 3956-2008 Conductors of Insulated Cables
GB/T 5013.1-2008 Rubber Insulated Cables of Rated Voltages Up to and Including 450/750V — Part 1: General Requirements (IEC 60245-1:2003)
GB/T 5013.2-2008 Rubber Insulated Cables of Rated Voltages Up to and Including 450/750V — Part 2: Test Methods (IEC 60245:1998)
GB/T 17650.1-1998 Test on Gases Evolved during Combustion of Materials from Cables — Part 1: Determination of the Halogen Acid Gas Content
GB/T 17650.2-1998 Test on Gases Evolved during Combustion of Materials from Cables — Part 2: Determination of Degree of Acidity of Gases by Measuring pH and Conductivity
GB/T 17737.1-2000 Radio-frequency Cables — Part 1: Generic Specification — General, Definitions, Requirements and Test Methods
GB/T 18380.12-2008 Tests on Electric Cables under Fire Conditions — Part 12: Test for Vertical Flame Propagation for a Single Insulated Wire or Cable — Procedure for 1kW Pre-mixed Flame (IEC 60332-1-2:2004)
GB/T 18487.1-2001 Electric Vehicle Conductive Charging System — Part 1: General Requirements
GB/T 20234.1-2011 Connection Set of Conductive Charging for Electric Vehicles — Part 1: General Requirements
GB/T 20234.2-2011 Connection Set of Conductive Charging for Electric Vehicles — Part 2: AC Charging Coupler
GB/T 20234.3-2011 Connection Set of Conductive Charging for Electric Vehicles — Part 3: DC Charging Coupler
IEC 60684-2:2003 Flexible Insulating Sleeving — Part 2: Methods of Test
EN 50289-4-17-2011 Communication Cables — Specifications for Test Methods — Part 4-17: Test Methods for UV Resistance Evaluation of the Sheath of Electrical and Optical Fibre Cable
CQC1103-2015 Technical Specification for Cables of Electric Vehicles Conductive Charging Systems — Part 1: General Requirement
3 Operating Characteristics
3.1 Rated voltage
450/750V
3.2 Operating temperature of cable
Long-term allowable operating temperature of cables shall be in accordance with those specified in Table 2 of CQC1103-2015.
3.3 Service temperature of cable laying
Recommended ambient temperature range of cables is: -40℃ (or -25℃)~+50℃.
3.4 Allowable bending radius of cables
The bending radius of cables shall not be less than 6 times of the outside diameter of cables.
4 Cable Construction and Technical Requirements
4.1 Conductor
Conductors shall be in accordance with the requirements specified in 6.1 of CQC1103-2015.
Nominal sectional area of conductors for power core: 1, 1.5, 2.5, 4, 6, 10, 16, 25, 35, 50, 70mm2.
Nominal sectional area of conductors for signal and control cores: 0.5, 0.75, 1mm2 (nominal sectional area 0.3 and 0.4mm2 are allowable; the maximum diameter of single wire in the conductor is 0.16mm; the maximum resistance of the conductor at 20℃: 69.2 and 48.2Ω/km for copper core, and 71.2 and 49.6Ω/km for tinned copper core).
4.2 Insulation
The insulation shall be any extruded and moulded compound listed in Table 2 of CQC1103-2015.
Properties of insulation materials shall be in accordance with those specified in Table 6 of CQC1103-2015.
Nominal thickness of insulation shall be in accordance with those specified in Tables 1 and 2, and the thickness of isolating layer shall not included in the insulation thickness.
Mean insulation thickness shall not be less than the nominal values specified in Tables 1 and 2, the insulation thickness at the thinnest part shall not less than the difference of 90% of the nominal value minus 0.1mm.
4.3 Insulated core strand and filling materials
Insulated core and filling materials shall be in accordance with those specified in 6.4 of CQC1103-2015.
Stranded lay ratio of cable core shall not greater than 16 times.
4.4 Inner sheath
Inner sheath shall be in accordance with those specified in 6.5 of CQC1103-2015.
Mechanical and physical properties of inner sheath shall be in accordance with those specified in Tables 6 and 7 of CQC1103-2015.
Nominal thickness of inner sheath is 0.6mm, and the average thickness of inner sheath shall not be less than the nominal value.
4.5 Overall shield
Bare round copper wire or tinned copper wire shall be adopted for weaving the metal overall shield (if any) at inner sheath.
Woven shield shall be in accordance with those specified in 6.6 of CQC1103-2015.
Knitting tightness of shield layer shall not be less than 80%.
4.6 Sheath or outer sheath
Sheath or outer sheath of cable shall be in accordance with those specified in 6.7 of CQC1103-2015, and material properties shall be in accordance with those specified in Table 7 of CQC1103-2015.
The average thickness of sheath or outer sheath shall not be less than the nominal value, and the thickness at the thinnest part shall not be less than the difference of 85% of the nominal value minus 0.1mm.
Nominal value of thickness of sheath or outer sheath shall not be less than those specified in Tables 1 and 2 of this specification.
4.7 Signal and control cores
Signal and control cores shall be in accordance with those specified in 6.8 of CQC1103-2015.
Shielded signal and control cores may be covered by a single layer of extruded or wrapped inner lining (with the same materials of insulation or sheath), and the nominal thickness of inner lining shall not less than 0.3mm.
4.8 Overall diameter of cable
Outside diameter of cable, f, shall be in accordance with those specified in 6.9 of CQC1103-2015.
1 Scope
2 Normative References
3 Operating Characteristics
3.1 Rated voltage
3.2 Operating temperature of cable
3.3 Service temperature of cable laying
3.4 Allowable bending radius of cables
4 Cable Construction and Technical Requirements
4.1 Conductor
4.2 Insulation
4.3 Insulated core strand and filling materials
4.4 Inner sheath
4.5 Overall shield
4.6 Sheath or outer sheath
4.7 Signal and control cores
4.8 Overall diameter of cable
5 Test Requirements
6 Cable Mark
6.1 Coloured chromatogram of cable insulation core
7 Test Methods and Inspection Rules
8 Packaging, Transportation and Storage
Table 1 Structural Table of Thermoplastic Insulated Cable
Table 2 Structural Table of Thermosetting Insulated Cable
Table 3 Test Items of Cable
Table 4 Colour of AC Charging Cable Core and Functional Description
CQC 1104-2015 Technical Specification for Cables of Electric Vehicles Conductive Charging Systems Part 2: Cables for AC Charging Systems (English Version)
Standard No.
CQC 1104-2015
Status
valid
Language
English
File Format
PDF
Word Count
4000 words
Price(USD)
80.0
Implemented on
2015-9-28
Delivery
via email in 1 business day
Detail of CQC 1104-2015
Standard No.
CQC 1104-2015
English Name
Technical Specification for Cables of Electric Vehicles Conductive Charging Systems Part 2: Cables for AC Charging Systems
This specification is drafted in accordance with GB/T 1.1-2009.
"Technical Specification for Cables of Electric Vehicles Conductive Charging Systems" series was proposed by China Quality Certification Center. It is one of technical specifications for voluntary certification of products. This series consists of the following 3 technical specifications:
CQC 1103 "Technical Specification for Cables of Electric Vehicles Conductive Charging Systems — Part 1: General Requirement"
CQC 1104 Technical Specification for Cables of Electric Vehicles Conductive Charging Systems — Part 2: Cables for AC Charging Systems
CQC 1105 Technical Specification for Cables of Electric Vehicles Conductive Charging Systems — Part 3: Cables for DC Charging Systems
This specification is the converted and updated version of three standard series: CQC1103-2014, CQC1104-2014, CQC1105-2014, TICW 18-2012 and K175-2014.
Compared with CQC1103~5-2014, except editorial changes, the main technical changes of this specification are as follows:
1. Expression method of product type and specification is revised;
2. Products of halogen-free and cross linking material series are added;
3. EV-VV, EV-S90S90, EV-YJYJ and other series products and relevant requirements are deleted;
4. Temperature grade and the requirements of tear resistance test of TPE sheath are revised;
5. The voltage of voltage test of finished cable was changed to 3500 V; specific voltage test method is specified;
6. Vehicle rolling compaction test, oil resistance test and capacitance increase rate after water penetration are deleted;
7. Extrusion test, reagent resistance test, abrasion resistance test, heat shrinkage test, insulation and long-term DC resistance test and hardness, weather resistance and saponification tests are newly added;
8. The insulation and sheath thickness of the product is adjusted, and the upper and lower limit requirements for outside diameter are deleted;
Chief drafting organizations of this specification:
China Quality Certification Center, National Quality Supervision and Testing Center for Cables and Wires, and DEKRA Certification B. V.
Cheif drafting staff of this specification:
Xie Zhiguo, Huang Xuan, Guan Lili, Li Na, Yang Juanjuan, Xiao Jidong, Zhu Yonghua, Wu Changshun, Hong Jian and Liu Weihai
Chief participating drafting organizations and drafting staff of this specification:
Wuxi Xinhongye Wire & Cable Co., Ltd. Guan Yong
Guangdong OMG Transmitting Technology Co., Ltd. Liu Yaoxun
Zhongli Science And Technology Group Co., Ltd. Sun Jianyu
Hengyang Hengfei Cable Co., Ltd. Wang Fushan
Jiangyin Seven-star Cable Co., Ltd. Gao Wei
Zhongtian Technology Instrument Cable Co., Ltd. Chen Shuai
Wuxi Mingzhu Cable Co., Ltd. Yu Jinhua
Technical Specification for Cables of Electric Vehicles Conductive Charging Systems
Part 2: Cables for AC Charging Systems
1 Scope
This specification specifies structure, size and test requirements of cables for AC conductive charging systems of electric vehicles of rated voltages up to and including 450/750V.
Cables included in this specification are applicable to the connection between electric vehicles and charging spot of low speed electric vehicle charging station, and applicable to the connection between portable charging equipment and charge power supply.
2 Normative References
The following normative documents contain provisions which, through reference in this text, constitute provisions of this specification. The following documents are indispensable for the application of this document. For dated references, only the dated editions apply. For undated references, the latest editions (including any amendments) apply.
GB/T 2900.10 Electrotechnical Vocabulary — Electric Cables
GB/T 2951.11-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables — Part 11: Methods for General Application — Measurement of Thickness and Overall Dimensions — Tests for Determining the Mechanical Properties (IEC 60811-1-1:2001)
GB/T 2951.12-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables — Part 12: Methods for General Application — Thermal Ageing Methods (IEC 60811-1-2:1985)
GB/T 2951.13-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables — Part 13: Methods for General Application — Measurement for Determining the Density — Water Absorption Tests — Shrinkage Test (IEC 60811-1-3:2001)
GB/T 2951.14-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables — Part 14: Methods for General Application — Test at Low Temperature (IEC 60811-1-4:1985)
GB/T 2951.21-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables — Part 21: Methods Specific to Elastomeric Compounds — Ozone Resistance, Hot Set and Mineral Oil Immersion Tests (IEC 60811-2-1:2001)
GB/T 2951.31-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables — Part 31: Methods Specific to PVC Compounds — Pressure Test at High Temperature — Test for Resistance to Cracking (IEC 60811-3-1:1985)
GB/T 3048.4-2007 Test Methods for Electrical Properties of Electric Cables and Wires — Part 4: Test of DC Resistance of Conductors
GB/T 3048.8-2007 Test Methods for Electrical Properties of Electric Cables and Wires — Part 8: AC Voltage Test
GB/T 3956-2008 Conductors of Insulated Cables
GB/T 5013.1-2008 Rubber Insulated Cables of Rated Voltages Up to and Including 450/750V — Part 1: General Requirements (IEC 60245-1:2003)
GB/T 5013.2-2008 Rubber Insulated Cables of Rated Voltages Up to and Including 450/750V — Part 2: Test Methods (IEC 60245:1998)
GB/T 17650.1-1998 Test on Gases Evolved during Combustion of Materials from Cables — Part 1: Determination of the Halogen Acid Gas Content
GB/T 17650.2-1998 Test on Gases Evolved during Combustion of Materials from Cables — Part 2: Determination of Degree of Acidity of Gases by Measuring pH and Conductivity
GB/T 17737.1-2000 Radio-frequency Cables — Part 1: Generic Specification — General, Definitions, Requirements and Test Methods
GB/T 18380.12-2008 Tests on Electric Cables under Fire Conditions — Part 12: Test for Vertical Flame Propagation for a Single Insulated Wire or Cable — Procedure for 1kW Pre-mixed Flame (IEC 60332-1-2:2004)
GB/T 18487.1-2001 Electric Vehicle Conductive Charging System — Part 1: General Requirements
GB/T 20234.1-2011 Connection Set of Conductive Charging for Electric Vehicles — Part 1: General Requirements
GB/T 20234.2-2011 Connection Set of Conductive Charging for Electric Vehicles — Part 2: AC Charging Coupler
GB/T 20234.3-2011 Connection Set of Conductive Charging for Electric Vehicles — Part 3: DC Charging Coupler
IEC 60684-2:2003 Flexible Insulating Sleeving — Part 2: Methods of Test
EN 50289-4-17-2011 Communication Cables — Specifications for Test Methods — Part 4-17: Test Methods for UV Resistance Evaluation of the Sheath of Electrical and Optical Fibre Cable
CQC1103-2015 Technical Specification for Cables of Electric Vehicles Conductive Charging Systems — Part 1: General Requirement
3 Operating Characteristics
3.1 Rated voltage
450/750V
3.2 Operating temperature of cable
Long-term allowable operating temperature of cables shall be in accordance with those specified in Table 2 of CQC1103-2015.
3.3 Service temperature of cable laying
Recommended ambient temperature range of cables is: -40℃ (or -25℃)~+50℃.
3.4 Allowable bending radius of cables
The bending radius of cables shall not be less than 6 times of the outside diameter of cables.
4 Cable Construction and Technical Requirements
4.1 Conductor
Conductors shall be in accordance with the requirements specified in 6.1 of CQC1103-2015.
Nominal sectional area of conductors for power core: 1, 1.5, 2.5, 4, 6, 10, 16, 25, 35, 50, 70mm2.
Nominal sectional area of conductors for signal and control cores: 0.5, 0.75, 1mm2 (nominal sectional area 0.3 and 0.4mm2 are allowable; the maximum diameter of single wire in the conductor is 0.16mm; the maximum resistance of the conductor at 20℃: 69.2 and 48.2Ω/km for copper core, and 71.2 and 49.6Ω/km for tinned copper core).
4.2 Insulation
The insulation shall be any extruded and moulded compound listed in Table 2 of CQC1103-2015.
Properties of insulation materials shall be in accordance with those specified in Table 6 of CQC1103-2015.
Nominal thickness of insulation shall be in accordance with those specified in Tables 1 and 2, and the thickness of isolating layer shall not included in the insulation thickness.
Mean insulation thickness shall not be less than the nominal values specified in Tables 1 and 2, the insulation thickness at the thinnest part shall not less than the difference of 90% of the nominal value minus 0.1mm.
4.3 Insulated core strand and filling materials
Insulated core and filling materials shall be in accordance with those specified in 6.4 of CQC1103-2015.
Stranded lay ratio of cable core shall not greater than 16 times.
4.4 Inner sheath
Inner sheath shall be in accordance with those specified in 6.5 of CQC1103-2015.
Mechanical and physical properties of inner sheath shall be in accordance with those specified in Tables 6 and 7 of CQC1103-2015.
Nominal thickness of inner sheath is 0.6mm, and the average thickness of inner sheath shall not be less than the nominal value.
4.5 Overall shield
Bare round copper wire or tinned copper wire shall be adopted for weaving the metal overall shield (if any) at inner sheath.
Woven shield shall be in accordance with those specified in 6.6 of CQC1103-2015.
Knitting tightness of shield layer shall not be less than 80%.
4.6 Sheath or outer sheath
Sheath or outer sheath of cable shall be in accordance with those specified in 6.7 of CQC1103-2015, and material properties shall be in accordance with those specified in Table 7 of CQC1103-2015.
The average thickness of sheath or outer sheath shall not be less than the nominal value, and the thickness at the thinnest part shall not be less than the difference of 85% of the nominal value minus 0.1mm.
Nominal value of thickness of sheath or outer sheath shall not be less than those specified in Tables 1 and 2 of this specification.
4.7 Signal and control cores
Signal and control cores shall be in accordance with those specified in 6.8 of CQC1103-2015.
Shielded signal and control cores may be covered by a single layer of extruded or wrapped inner lining (with the same materials of insulation or sheath), and the nominal thickness of inner lining shall not less than 0.3mm.
4.8 Overall diameter of cable
Outside diameter of cable, f, shall be in accordance with those specified in 6.9 of CQC1103-2015.
Contents of CQC 1104-2015
1 Scope
2 Normative References
3 Operating Characteristics
3.1 Rated voltage
3.2 Operating temperature of cable
3.3 Service temperature of cable laying
3.4 Allowable bending radius of cables
4 Cable Construction and Technical Requirements
4.1 Conductor
4.2 Insulation
4.3 Insulated core strand and filling materials
4.4 Inner sheath
4.5 Overall shield
4.6 Sheath or outer sheath
4.7 Signal and control cores
4.8 Overall diameter of cable
5 Test Requirements
6 Cable Mark
6.1 Coloured chromatogram of cable insulation core
7 Test Methods and Inspection Rules
8 Packaging, Transportation and Storage
Table 1 Structural Table of Thermoplastic Insulated Cable
Table 2 Structural Table of Thermosetting Insulated Cable
Table 3 Test Items of Cable
Table 4 Colour of AC Charging Cable Core and Functional Description