2023-5-29 44.200.112.172
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/JB/T 1009-2007
JB/T 1009-2007   Specification for YS series three-phase asynchronous motors (English Version)
Standard No.: JB/T 1009-2007 Status:superseded remind me the status change

Email:

Language:English File Format:PDF
Word Count: 4000 words Price(USD):100.0 remind me the price change

Email:

Implemented on:2007-7-1 Delivery: via email in 1 business day
,,
Standard No.: JB/T 1009-2007
English Name: Specification for YS series three-phase asynchronous motors
Chinese Name: YS系列三相异步电动机技术条件
Chinese Classification: K22    Asynchronous machine
Professional Classification: JB    Professional Standard - Machinery
ICS Classification: 29.160.30 29.160.30    Motors 29.160.30
Issued by: NDRC
Issued on: 2007-01-25
Implemented on: 2007-7-1
Status: superseded
Superseded by:JB/T 1009-2016 Specification for YS series three-phase asynchronous motors
Superseded on:2017-4-1
Abolished on:2017-04-01
Superseding:JB/T 1009-1991
Language: English
File Format: PDF
Word Count: 4000 words
Price(USD): 100.0
Delivery: via email in 1 business day
Specification for YS Series Three-phase Asynchronous Motors YS系列三相异步电动机技术条件 1 Scope This standard specifies YS series three-phase asynchronous motor in terms of type, basic parameters and dimension, requirements, test methods, inspection rules and requirements for marking and packaging. This standard is applicable to YS series three-phase asynchronous motor (frame size 45-90) (hereinafter referred to as motor), and all other series motors derived from YS series three-phase asynchronous motor may also refer. 2 Normative References The following standards contain provisions which, through reference in this standard, constitute provisions of this standard. For dated reference, subsequent amendments to (excluding correction to), or revisions of, any of these publications do not apply. However, the parties coming to an agreement based on this standard are encouraged to investigate whether the most recent editions of the standards apply. For undated references, the latest editions of the normative documents referred to apply. GB/T 191-2000 Packaging - Pictorial Marking for Handling of Goods (eqv ISO 780:1997) GB 755-2000 Rotating Electrical Machines - Rating and Performance (idt IEC60034-1:1996) GB/T 1032-2005 Test Procedure for Three-phase Induction Motors GB/T 2828.1-2003 Sampling Procedures for Inspection by Attributea - Part 1: Sampling Schemes Indexed by Acceptance Quality Limit(AQL) for Lot-by-Lot Inspection (ISO 2859-1:1999, IDT) GB/T 4772.1-1999 Dimensions and Output Series for Rotating Electrical Machines - Part 1: Frame numbers 56 to 400 and Flange Numbers 55 to 1080 (idt IEC 60072-1:1991) GB/T 4942.1-2006 Degrees of Protection Provided by the Integral Design of Rotating Electrical Machines (IP Code) - Classification (IEC 60034-5:2000, IDT) GB 10069.1-2006 Method for the Measurement of Airborne Noise Emitted by Rotating Electrical Machines Part 1: Method for the Measurement of Airborne Noise Emitted by Rotating Electrical Machines (ISO 1680:1999, MOD) GB 12350-2000 Safety Requirements of Small-power Motors GB/T 12665-1990 Requirements of Damp-heat Testing of Electrical Machine for Service in General Environmental Condition JB/T 9615.1-2000 Test Methods of the Interturn Insulation on Random Wound Winding for AC Low-voltage Machines JB/T 9615.2-2000 Test Limits of the Interturn Insulation on Random Wound Winding for AC Low-voltage Machines JB/T 10490-2004 Mechanical Vibration of Small Power Motors - Measurement,Evaluation and Limits of Vibration 3 Types, Basic Parameters and Dimensions 3.1 The protection level of motor enclosure adopts IP44, IP54 or IP55. 3.2 Method of cooling motor: IC 0141 for frame size ≥63; IC 0041 for frame size ≤56. 3.3 The construction and mounting type of motors shall meet the requirements of Table 1. Table 1 Frame size Construction and mounting code (IM) 45~56 B3, B14, B34, V5, V6, V18, V19 63~80 B3, B5, B14, B34, V1, V3, V5, V6, V18, V19 90 B3, B5, B14, B34, B35, V1, V3, V5, V6, V18, V19, V36 3.4 Rating of the motor is continuous based on continuous duty (S1). 3.5 Rated frequency and rated voltage of motors are 50Hz and 220/380V respectively and the motor with frame size ≤71 may use 380V. 3.6 Motors shall be manufactured according to the following rated powers (in W): 10, 16, 25, 40, 60, 90, 120, 180, 250, 370, 550, 750, 1100, 1500, 2200. 3.7 The corresponding relation of frame size, rotating speed and pow
Contents Foreword I 1 Scope 2 Normative References 3 Types, Basic Parameters and Dimensions 4 Technical Requirements 5 Test Methods 6 Inspection Rules 7 Marking and Packaging 8 Quality Warranty Period
Referred in JB/T 1009-2007:
*GB/T 191-2000 Packaging - Pictorial marking for handling of goods
*GB 755-2000 Rotating electrical machines--Rating and performance
*GB/T 1032-2005 Test procedures for three-phase induction motors
*GB/T 2828.1-2003 Sampling procedures for inspection by attributea-Part1:Sampling schemes indexed by acceptance quality limit(AQL) for lot-by-lot inspection
*GB/T 4772.1-1999 Dimensions and output series for rotating electrical machines -Part 1:Frame numbers 56 to 400 and flange numbers 55 to 1 080
*GB/T 4942.1-2006 Degrees of Protection Provided by the Integral Design of Rotating Electrical Machined (IP Code)-Classification
*GB10069.1-2006
*GB 12350-2000 Safety requirments of small power motors
*GB/T 12665-1990 Requirements of damp-heat testing of electrical machine for service in general environmental condition
*JB/T 9615.1-2000 test methods of the interturn insulation on random wound winding for ac low-voltage machines
*JB/T 9615.2-2000 test limits of the interturn insulation on random wound winding for ac low-voltage machines
*JB/T 10490-2004 Mechanical vibration of small power motors—measurement,evaluation and limits of vibration
Code of China
Standard
JB/T 1009-2007  Specification for YS series three-phase asynchronous motors (English Version)
Standard No.JB/T 1009-2007
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count4000 words
Price(USD)100.0
Implemented on2007-7-1
Deliveryvia email in 1 business day
Detail of JB/T 1009-2007
Standard No.
JB/T 1009-2007
English Name
Specification for YS series three-phase asynchronous motors
Chinese Name
YS系列三相异步电动机技术条件
Chinese Classification
K22
Professional Classification
JB
ICS Classification
Issued by
NDRC
Issued on
2007-01-25
Implemented on
2007-7-1
Status
superseded
Superseded by
JB/T 1009-2016 Specification for YS series three-phase asynchronous motors
Superseded on
2017-4-1
Abolished on
2017-04-01
Superseding
JB/T 1009-1991
Language
English
File Format
PDF
Word Count
4000 words
Price(USD)
100.0
Keywords
JB/T 1009-2007, JB 1009-2007, JBT 1009-2007, JB/T1009-2007, JB/T 1009, JB/T1009, JB1009-2007, JB 1009, JB1009, JBT1009-2007, JBT 1009, JBT1009
Introduction of JB/T 1009-2007
Specification for YS Series Three-phase Asynchronous Motors YS系列三相异步电动机技术条件 1 Scope This standard specifies YS series three-phase asynchronous motor in terms of type, basic parameters and dimension, requirements, test methods, inspection rules and requirements for marking and packaging. This standard is applicable to YS series three-phase asynchronous motor (frame size 45-90) (hereinafter referred to as motor), and all other series motors derived from YS series three-phase asynchronous motor may also refer. 2 Normative References The following standards contain provisions which, through reference in this standard, constitute provisions of this standard. For dated reference, subsequent amendments to (excluding correction to), or revisions of, any of these publications do not apply. However, the parties coming to an agreement based on this standard are encouraged to investigate whether the most recent editions of the standards apply. For undated references, the latest editions of the normative documents referred to apply. GB/T 191-2000 Packaging - Pictorial Marking for Handling of Goods (eqv ISO 780:1997) GB 755-2000 Rotating Electrical Machines - Rating and Performance (idt IEC60034-1:1996) GB/T 1032-2005 Test Procedure for Three-phase Induction Motors GB/T 2828.1-2003 Sampling Procedures for Inspection by Attributea - Part 1: Sampling Schemes Indexed by Acceptance Quality Limit(AQL) for Lot-by-Lot Inspection (ISO 2859-1:1999, IDT) GB/T 4772.1-1999 Dimensions and Output Series for Rotating Electrical Machines - Part 1: Frame numbers 56 to 400 and Flange Numbers 55 to 1080 (idt IEC 60072-1:1991) GB/T 4942.1-2006 Degrees of Protection Provided by the Integral Design of Rotating Electrical Machines (IP Code) - Classification (IEC 60034-5:2000, IDT) GB 10069.1-2006 Method for the Measurement of Airborne Noise Emitted by Rotating Electrical Machines Part 1: Method for the Measurement of Airborne Noise Emitted by Rotating Electrical Machines (ISO 1680:1999, MOD) GB 12350-2000 Safety Requirements of Small-power Motors GB/T 12665-1990 Requirements of Damp-heat Testing of Electrical Machine for Service in General Environmental Condition JB/T 9615.1-2000 Test Methods of the Interturn Insulation on Random Wound Winding for AC Low-voltage Machines JB/T 9615.2-2000 Test Limits of the Interturn Insulation on Random Wound Winding for AC Low-voltage Machines JB/T 10490-2004 Mechanical Vibration of Small Power Motors - Measurement,Evaluation and Limits of Vibration 3 Types, Basic Parameters and Dimensions 3.1 The protection level of motor enclosure adopts IP44, IP54 or IP55. 3.2 Method of cooling motor: IC 0141 for frame size ≥63; IC 0041 for frame size ≤56. 3.3 The construction and mounting type of motors shall meet the requirements of Table 1. Table 1 Frame size Construction and mounting code (IM) 45~56 B3, B14, B34, V5, V6, V18, V19 63~80 B3, B5, B14, B34, V1, V3, V5, V6, V18, V19 90 B3, B5, B14, B34, B35, V1, V3, V5, V6, V18, V19, V36 3.4 Rating of the motor is continuous based on continuous duty (S1). 3.5 Rated frequency and rated voltage of motors are 50Hz and 220/380V respectively and the motor with frame size ≤71 may use 380V. 3.6 Motors shall be manufactured according to the following rated powers (in W): 10, 16, 25, 40, 60, 90, 120, 180, 250, 370, 550, 750, 1100, 1500, 2200. 3.7 The corresponding relation of frame size, rotating speed and pow
Contents of JB/T 1009-2007
Contents Foreword I 1 Scope 2 Normative References 3 Types, Basic Parameters and Dimensions 4 Technical Requirements 5 Test Methods 6 Inspection Rules 7 Marking and Packaging 8 Quality Warranty Period
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Foryou Tech Co., Ltd. 2008-2040
 
 
Keywords:
JB/T 1009-2007, JB 1009-2007, JBT 1009-2007, JB/T1009-2007, JB/T 1009, JB/T1009, JB1009-2007, JB 1009, JB1009, JBT1009-2007, JBT 1009, JBT1009