2023-6-3 44.200.82.149
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/JB/T 5269-2007
JB/T 5269-2007   Specification for YR3 series (IP23) Three-phase Asynchronous Motor (frame size 160~355) (English Version)
Standard No.: JB/T 5269-2007 Status:superseded remind me the status change

Email:

Language:English File Format:PDF
Word Count: 4500 words Price(USD):110.0 remind me the price change

Email:

Implemented on:2007-11-1 Delivery: via email in 1 business day
,,
Standard No.: JB/T 5269-2007
English Name: Specification for YR3 series (IP23) Three-phase Asynchronous Motor (frame size 160~355)
Chinese Name: YR3系列(IP23)三相异步电动机 技术条件(机座号160~355)
Chinese Classification: K22    Asynchronous machine
Professional Classification: JB    Professional Standard - Machinery
ICS Classification: 29.160.30 29.160.30    Motors 29.160.30
Issued by: NDRC
Issued on: 2007-5-29
Implemented on: 2007-11-1
Status: superseded
Superseded by:JB/T 5269-2018 Specification for YR3 series (IP23) three-phase asynchronous motor (frame size 160~400)
Superseded on:2019-10-1
Superseding:JB/T 5270-1991
Language: English
File Format: PDF
Word Count: 4500 words
Price(USD): 110.0
Delivery: via email in 1 business day
1 Scope This standard specifies the types, basic parameters and dimensions, technical requirements, inspection rules, and requirements for marking, packaging and warranty period of YR3 series (IP23) three-phase asynchronous motor. This standard is applicable to YR3 series (IP23) three-phase asynchronous motor (frame size 160~355) (hereinafter referred to as "motor"), and all other series motors derived from YR3 series (IP23) three-phase asynchronous motor may also refer. 2 Normative Reference The following standards contain provisions which, through reference in this standard, constitute provisions of this standard. For dated reference, subsequent amendments to (excluding correction to), or revisions of, any of these publications do not apply. However, the parties coming to an agreement based on this standard are encouraged to investigate whether the most recent editions of the standards indicated below apply. For undated references, the latest editions of the normative documents referred to apply. GB/T 191-2000 Packaging - Pictorial Marking for Handling of Goods (eqv ISO 780: 1997) GB 755-2000 Rotating Electrical Machines - Rating and Performance (idt IEC 60034-1: 1996) GB/T 997-2003 Classification of Types of Construction and Mounting Arrangements for Rotating Electrical Machines (IM Code) (IEC 60034-7: 1992, IDT) GB/T 1032-2005 Test Procedure for Three-phase Induction Motors GB/T 1993-1993 Cooling Methods for Rotating Electrical Machines (idt IEC 60034-6: 1991) GB/T 4772.1-1999 Dimensions and Output Series for Rotating Electrical Machines - Part 1: Frame Numbers 56 to 400 and Flange Numbers 55 to 1080 (idt IEC 60072-1: 1991) GB/T 4942.1-2006 Degrees of Protection Provided by the Integral Design of Rotating Electrical Machines (IP Code) - Classification (IEC 60034-5: 2000, IDT) GB 10068-2000 Mechanical Vibration of Certain Machines with Shaft Heights 56mm and Higher - Measurement, Evaluation and Limits of Vibration Severity (idt IEC: 60034-14: 1996) GB/T 10069.1-2006 Measurement of The Airborne Noise Emitted by Rotating Electrical Machinery and the Noise Limits - Part 1: Method for the Measurement of Airborne Noise Emitted by Rotating Electrical Machines (ISO 1680: 1999, MOD) GB/T 12665-1990 Requirements of Damp-heat Testing of Electrical Machine for Service in General Environment Condition GB 14711-2006 Safety Requirements of Small and Medium Size Rotating Electrical Machines JB/T 5811-2007 Test Method and Limits of Form-wound Winding for Alternating Current Low-voltage Electrical Machines JB/T 9615.1-2000 Test Methods of the Interturn Insulation on Random Wound Winding for AC Low-voltage Machines JB/T 9615.2-2000 Test Limits of the Interturn Insulation on Random Wound Winding for AC Low-voltage Machines 3 Types, Basic Parameters and Dimensions 3.1 Enclosure protection level of motor is IP23 (as specified in GB/T 4942.1). 3.2 The method for cooling motor is IC01 (as specified in GB/T 1993). 3.3 Construction and mounting types of motor are IM B3 (as specified in GB/T 997). 3.4 Rating of the motor is continuous based on continuous duty system (S1). 3.5 Rated frequency and voltage of motor are respectively 50Hz and 380V. Stator windings are delta-connected and rotor windings are wye-connected. 3.6 Motors shall be manufactured according to the following rated powers: 4kW, 5.5kW, 7.5kW, 11kW, 15kW, 18.5 kW, 22kW, 30kW, 37kW, 45kW, 55kW, 75 kW, 90kW, 110kW, 132kW, 160kW, 185kW, 200kW, 220kW, 250kW, 280kW, 315kW, 355kW.
Contents Foreword I 1 Scope 2 Normative Reference 3 Types, Basic Parameters and Dimensions 4 Technical Requirements 5 Inspection Rules 6 Marking, Packaging and Warranty Period Figure 1 Motor with Foot on Frame and No Flange on End Cover (H160~280) Figure 2 Motor with Foot on Frame and No Flange on End Cover (H315~355)
Referred in JB/T 5269-2007:
*GB/T 191-2000 Packaging - Pictorial marking for handling of goods
*GB 755-2000 Rotating electrical machines--Rating and performance
*GB/T 997-2003 Classification of types of construction and mounting arrangements for rotating electrical machines(IM code)
*GB/T 1032-2005 Test procedures for three-phase induction motors
*GB/T 1993-1993 Cooling methods for rotating electrical machines
*GB/T 4772.1-1999 Dimensions and output series for rotating electrical machines -Part 1:Frame numbers 56 to 400 and flange numbers 55 to 1 080
*GB/T 4942.1-2006 Degrees of Protection Provided by the Integral Design of Rotating Electrical Machined (IP Code)-Classification
*GB 10068-2000 Mechanicalvibration of certain machines with shaft heights 56 mm and higher--Measurement,evaluation and limits of vibration
*GB/T 10069.1-2006 Measurement of airborne noise emitted by rotating electrical machines and the noise limits Part 1: Method for the measurement of airborne noise emitted by rotating electrical machines
*GB/T 12665-1990 Requirements of damp-heat testing of electrical machine for service in general environmental condition
*GB 14711-2006 Safety Requirements of Small and Medium Size Rotating Electrical Machines
*JB/T 5811-2007 Test method and limits of form-wound winding for alternating current low-voltage electrical mechines
*JB/T 9615.1-2000 test methods of the interturn insulation on random wound winding for ac low-voltage machines
*JB/T 9615.2-2000 test limits of the interturn insulation on random wound winding for ac low-voltage machines
Code of China
Standard
JB/T 5269-2007  Specification for YR3 series (IP23) Three-phase Asynchronous Motor (frame size 160~355) (English Version)
Standard No.JB/T 5269-2007
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count4500 words
Price(USD)110.0
Implemented on2007-11-1
Deliveryvia email in 1 business day
Detail of JB/T 5269-2007
Standard No.
JB/T 5269-2007
English Name
Specification for YR3 series (IP23) Three-phase Asynchronous Motor (frame size 160~355)
Chinese Name
YR3系列(IP23)三相异步电动机 技术条件(机座号160~355)
Chinese Classification
K22
Professional Classification
JB
ICS Classification
Issued by
NDRC
Issued on
2007-5-29
Implemented on
2007-11-1
Status
superseded
Superseded by
JB/T 5269-2018 Specification for YR3 series (IP23) three-phase asynchronous motor (frame size 160~400)
Superseded on
2019-10-1
Abolished on
Superseding
JB/T 5270-1991
Language
English
File Format
PDF
Word Count
4500 words
Price(USD)
110.0
Keywords
JB/T 5269-2007, JB 5269-2007, JBT 5269-2007, JB/T5269-2007, JB/T 5269, JB/T5269, JB5269-2007, JB 5269, JB5269, JBT5269-2007, JBT 5269, JBT5269
Introduction of JB/T 5269-2007
1 Scope This standard specifies the types, basic parameters and dimensions, technical requirements, inspection rules, and requirements for marking, packaging and warranty period of YR3 series (IP23) three-phase asynchronous motor. This standard is applicable to YR3 series (IP23) three-phase asynchronous motor (frame size 160~355) (hereinafter referred to as "motor"), and all other series motors derived from YR3 series (IP23) three-phase asynchronous motor may also refer. 2 Normative Reference The following standards contain provisions which, through reference in this standard, constitute provisions of this standard. For dated reference, subsequent amendments to (excluding correction to), or revisions of, any of these publications do not apply. However, the parties coming to an agreement based on this standard are encouraged to investigate whether the most recent editions of the standards indicated below apply. For undated references, the latest editions of the normative documents referred to apply. GB/T 191-2000 Packaging - Pictorial Marking for Handling of Goods (eqv ISO 780: 1997) GB 755-2000 Rotating Electrical Machines - Rating and Performance (idt IEC 60034-1: 1996) GB/T 997-2003 Classification of Types of Construction and Mounting Arrangements for Rotating Electrical Machines (IM Code) (IEC 60034-7: 1992, IDT) GB/T 1032-2005 Test Procedure for Three-phase Induction Motors GB/T 1993-1993 Cooling Methods for Rotating Electrical Machines (idt IEC 60034-6: 1991) GB/T 4772.1-1999 Dimensions and Output Series for Rotating Electrical Machines - Part 1: Frame Numbers 56 to 400 and Flange Numbers 55 to 1080 (idt IEC 60072-1: 1991) GB/T 4942.1-2006 Degrees of Protection Provided by the Integral Design of Rotating Electrical Machines (IP Code) - Classification (IEC 60034-5: 2000, IDT) GB 10068-2000 Mechanical Vibration of Certain Machines with Shaft Heights 56mm and Higher - Measurement, Evaluation and Limits of Vibration Severity (idt IEC: 60034-14: 1996) GB/T 10069.1-2006 Measurement of The Airborne Noise Emitted by Rotating Electrical Machinery and the Noise Limits - Part 1: Method for the Measurement of Airborne Noise Emitted by Rotating Electrical Machines (ISO 1680: 1999, MOD) GB/T 12665-1990 Requirements of Damp-heat Testing of Electrical Machine for Service in General Environment Condition GB 14711-2006 Safety Requirements of Small and Medium Size Rotating Electrical Machines JB/T 5811-2007 Test Method and Limits of Form-wound Winding for Alternating Current Low-voltage Electrical Machines JB/T 9615.1-2000 Test Methods of the Interturn Insulation on Random Wound Winding for AC Low-voltage Machines JB/T 9615.2-2000 Test Limits of the Interturn Insulation on Random Wound Winding for AC Low-voltage Machines 3 Types, Basic Parameters and Dimensions 3.1 Enclosure protection level of motor is IP23 (as specified in GB/T 4942.1). 3.2 The method for cooling motor is IC01 (as specified in GB/T 1993). 3.3 Construction and mounting types of motor are IM B3 (as specified in GB/T 997). 3.4 Rating of the motor is continuous based on continuous duty system (S1). 3.5 Rated frequency and voltage of motor are respectively 50Hz and 380V. Stator windings are delta-connected and rotor windings are wye-connected. 3.6 Motors shall be manufactured according to the following rated powers: 4kW, 5.5kW, 7.5kW, 11kW, 15kW, 18.5 kW, 22kW, 30kW, 37kW, 45kW, 55kW, 75 kW, 90kW, 110kW, 132kW, 160kW, 185kW, 200kW, 220kW, 250kW, 280kW, 315kW, 355kW.
Contents of JB/T 5269-2007
Contents Foreword I 1 Scope 2 Normative Reference 3 Types, Basic Parameters and Dimensions 4 Technical Requirements 5 Inspection Rules 6 Marking, Packaging and Warranty Period Figure 1 Motor with Foot on Frame and No Flange on End Cover (H160~280) Figure 2 Motor with Foot on Frame and No Flange on End Cover (H315~355)