2025-5-19 18.97.9.169
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/YY/T 0740-2009
YY/T 0740-2009   Particular specifications for medical X-ray angiography equipment (English Version)
Standard No.: YY/T 0740-2009 Status:superseded remind me the status change

Email:

Language:English File Format:PDF
Word Count: 6000 words Price(USD):150.0 remind me the price change

Email:

Implemented on:2010-12-1 Delivery: via email in 1 business day
,,
Standard No.: YY/T 0740-2009
English Name: Particular specifications for medical X-ray angiography equipment
Chinese Name: 医用血管造影X射线机专用技术条件
Chinese Classification: C43    Medical radiographic equipment
Professional Classification: YY    Professional Standard - Pharmaceutics
ICS Classification: 11.040.50 11.040.50    Radiographic equipment 11.040.50
Issued by: SFDA
Issued on: 2009-11-25
Implemented on: 2010-12-1
Status: superseded
Superseded by:YY/T 0740-2022 Particular specifications for medical X-ray angiography equipment
Superseded on:2023-5-1
Language: English
File Format: PDF
Word Count: 6000 words
Price(USD): 150.0
Delivery: via email in 1 business day
1 Scope This standard specifies the classification, composition, requirement and test method of medical angiography X-ray equipment (hereinafter referred to as angiography equipment) that has the function of interventional procedures. This standard is applicable to X-ray equipment which is stated by the manufacturer and is suitable for long-time fluoroscopic guidance and interventional procedures. 2 Normative References The provisions in the following documents, through reference in this standard, constitute the provisions of this standard. For dated reference, subsequent amendments (excluding corrigendum), or revisions of, any of these publications do not apply. However, all parties coming to an agreement according to this standard are encouraged to study whether the latest edition of these documents is applicable. For undated references, the latest edition of the normative document is applicable to this standard. GB 9706.1- 2007 Medical Electrical Equipment - Part 1: General Requirements for Safety (IEC 60601-1: 1988, IDT) GB 9706.3 - 2000 Medical Electrical Equipment - Part 2: Particular Requirements for the Safety of High-voltage Generators of Diagnostic X-ray Generators (IEC 60601-2-7: 1998, IDT) GB 9706.11-1997 Medical Electrical Equipment - Part 2: Particular Requirements for the Safety of X-ray Source Assemblies and X-ray Tube Assemblies for Medical Diagnosis (idt IEC 60601-2-28: 1993) GB 9706.12-1997 Medical Electrical Equipment - Part 1: General Requirements for Safety - 3. Collateral Standard: General Requirements for Radiation Protection in Diagnostic X-ray Equipment (idt IEC 60601-1-3: 1994) GB 9706.14-1997 Medical Electrical Equipment - Part 2: Particular Requirements for the Safety of Associated Equipment of X-ray Equipment (idt IEC 60601-2-32: 1994) GB 9706.15-2008 Medical Electrical Equipment - Part 1-1: General Requirements for Safety Collateral Standard: Safety Requirements for Medical Electrical Systems (IEC 60601-1-1: 2000, IDT) GB 9706.23-2005 Medical Electrical Equipment - Part 2-43: Particular Requirements for the Safety of X-ray Equipment for Interventional Procedures (IEC 60601-2-43: 2000, IDT) GB/T 10151-2008 Medical Diagnostic X-ray Equipment - Specifications for High Voltage Cable Plugs and Sockets GB/T 10149 Terminology and Symbol for Medical X-ray Equipment GB/T 19042.1-2003 Evaluation and Routine Testing in Medical Imaging Departments - Part 3-1: Acceptance Test - Imaging Performance of X-ray Equipment for Radiographic and Radioscopic Systems (IEC 61223-3-1: 1999, IDT) GB/T 19042.3-2005 Evaluation and Routine Testing in Medical Imaging Departments - Part 3-3: Acceptance Tests - Imaging Performance of X-ray Equipment for Digital Subtraction Angiography (DSA) (IEC 61223-3-3: 1996, IDT) YY 0076-1992 Coating Classifications for Metal Product Technical Conditions YY/T 0106-2008 General Specifications for Medical Diagnostic X-ray Equipment YY/T 0291-2007 Environmental Requirements and Test Methods for Medical X-ray Equipment YY 0505-2005 Medical Electrical Equipment - Part 1-2: General Requirements for Safety - Collateral Standards: Electromagnetic Compatibility - Requirements and Tests (IEC 60601-1-2: 2001, IDT) 3 Terms and Definitions For the purposes of this standard, the terms and definitions specified in GB/T 10149, GB/T 19042.1-2003, GB/T 19042.3-2005 and GB 9706.23-2005 as well as those listed below apply. 3.1 Imaging time The period required from the beginning of exposure to the display of normal image on the screen. 3.2 Stabilization of image brightness The automatic control capacity which may keep an invariable image brightness under different degenerative phantom.
Foreword I 1 Scope 2 Normative References 3 Terms and Definitions 4 Classification and Composition 5 Requirements 6 Test Methods Appendix A (Normative) Test Layout Appendix B (Normative) Test Phantom
Referred in YY/T 0740-2009:
* GB 9706.1-1995
* GB 9706.3-2000 Medical electrical equipment Part 2: Particular requirements for the safety of high-voltage generators of diagnostic X-ray generators
* GB 9706.11-1997 Medical electrical equipment-Part 2: Particular requirements for the safety of X-ray source assemblies and X-ray tube assemblies for medical diagnosis
* GB 9706.12-1997 Medical electrical equipment-Part 1: General requirements for safety 3.collateral STANDARD: General requirements for radiation protection in diagnostic X-ray equipment
* GB 9706.14-1997 Medical electrical equipment - Part 2: Particular requirements for the safety of associated equipment of X-ray equipment
* GB 9706.15-2008 Medical electrical equipment - Part 1: General requirements for safety - 1. Collateral standard: Safety requirements for medical electrical systems
* GB 9706.23-2005 Medical electrical equipment-Part2-43:Particular requirements for the safety of X-ray equipment for interventional procedures
* GB/T 10151-2008 Medical diagnostic X-ray equipment - Specifications for high voltage cable plugs and sockets
* GB/T 10149-1988 Terminology and symbol for medical X-ray equipment
* GB/T 19042.1-2003 Evaluation and routine testing in medical imaging departments--Part 3-1:Acceptance test-Imaging performance of X-ray equipment for radiographic and radioscopic systems
* GB/T 19042.3-2005 Evaluation and routine testing in medical imaging departments - Part3-3 :Acceptance tests - Imaging performance of X-ray equipment for digital subtraction angiography(DSA)
* YY 0076-1992 Coating classifications for metal product - Technical conditions
* YY/T-
* YY/T-
* YY 0505-2005 Medical electrical equipment?Part 1-2: General requirements for safety?Collateral stanards: Electromagnetic compatibility?Requirements and tests
Code of China
Standard
YY/T 0740-2009   Particular specifications for medical X-ray angiography equipment (English Version)
Standard No.YY/T 0740-2009
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count6000 words
Price(USD)150.0
Implemented on2010-12-1
Deliveryvia email in 1 business day
Detail of YY/T 0740-2009
Standard No.
YY/T 0740-2009
English Name
Particular specifications for medical X-ray angiography equipment
Chinese Name
医用血管造影X射线机专用技术条件
Chinese Classification
C43
Professional Classification
YY
ICS Classification
Issued by
SFDA
Issued on
2009-11-25
Implemented on
2010-12-1
Status
superseded
Superseded by
YY/T 0740-2022 Particular specifications for medical X-ray angiography equipment
Superseded on
2023-5-1
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
6000 words
Price(USD)
150.0
Keywords
YY/T 0740-2009, YY 0740-2009, YYT 0740-2009, YY/T0740-2009, YY/T 0740, YY/T0740, YY0740-2009, YY 0740, YY0740, YYT0740-2009, YYT 0740, YYT0740
Introduction of YY/T 0740-2009
1 Scope This standard specifies the classification, composition, requirement and test method of medical angiography X-ray equipment (hereinafter referred to as angiography equipment) that has the function of interventional procedures. This standard is applicable to X-ray equipment which is stated by the manufacturer and is suitable for long-time fluoroscopic guidance and interventional procedures. 2 Normative References The provisions in the following documents, through reference in this standard, constitute the provisions of this standard. For dated reference, subsequent amendments (excluding corrigendum), or revisions of, any of these publications do not apply. However, all parties coming to an agreement according to this standard are encouraged to study whether the latest edition of these documents is applicable. For undated references, the latest edition of the normative document is applicable to this standard. GB 9706.1- 2007 Medical Electrical Equipment - Part 1: General Requirements for Safety (IEC 60601-1: 1988, IDT) GB 9706.3 - 2000 Medical Electrical Equipment - Part 2: Particular Requirements for the Safety of High-voltage Generators of Diagnostic X-ray Generators (IEC 60601-2-7: 1998, IDT) GB 9706.11-1997 Medical Electrical Equipment - Part 2: Particular Requirements for the Safety of X-ray Source Assemblies and X-ray Tube Assemblies for Medical Diagnosis (idt IEC 60601-2-28: 1993) GB 9706.12-1997 Medical Electrical Equipment - Part 1: General Requirements for Safety - 3. Collateral Standard: General Requirements for Radiation Protection in Diagnostic X-ray Equipment (idt IEC 60601-1-3: 1994) GB 9706.14-1997 Medical Electrical Equipment - Part 2: Particular Requirements for the Safety of Associated Equipment of X-ray Equipment (idt IEC 60601-2-32: 1994) GB 9706.15-2008 Medical Electrical Equipment - Part 1-1: General Requirements for Safety Collateral Standard: Safety Requirements for Medical Electrical Systems (IEC 60601-1-1: 2000, IDT) GB 9706.23-2005 Medical Electrical Equipment - Part 2-43: Particular Requirements for the Safety of X-ray Equipment for Interventional Procedures (IEC 60601-2-43: 2000, IDT) GB/T 10151-2008 Medical Diagnostic X-ray Equipment - Specifications for High Voltage Cable Plugs and Sockets GB/T 10149 Terminology and Symbol for Medical X-ray Equipment GB/T 19042.1-2003 Evaluation and Routine Testing in Medical Imaging Departments - Part 3-1: Acceptance Test - Imaging Performance of X-ray Equipment for Radiographic and Radioscopic Systems (IEC 61223-3-1: 1999, IDT) GB/T 19042.3-2005 Evaluation and Routine Testing in Medical Imaging Departments - Part 3-3: Acceptance Tests - Imaging Performance of X-ray Equipment for Digital Subtraction Angiography (DSA) (IEC 61223-3-3: 1996, IDT) YY 0076-1992 Coating Classifications for Metal Product Technical Conditions YY/T 0106-2008 General Specifications for Medical Diagnostic X-ray Equipment YY/T 0291-2007 Environmental Requirements and Test Methods for Medical X-ray Equipment YY 0505-2005 Medical Electrical Equipment - Part 1-2: General Requirements for Safety - Collateral Standards: Electromagnetic Compatibility - Requirements and Tests (IEC 60601-1-2: 2001, IDT) 3 Terms and Definitions For the purposes of this standard, the terms and definitions specified in GB/T 10149, GB/T 19042.1-2003, GB/T 19042.3-2005 and GB 9706.23-2005 as well as those listed below apply. 3.1 Imaging time The period required from the beginning of exposure to the display of normal image on the screen. 3.2 Stabilization of image brightness The automatic control capacity which may keep an invariable image brightness under different degenerative phantom.
Contents of YY/T 0740-2009
Foreword I 1 Scope 2 Normative References 3 Terms and Definitions 4 Classification and Composition 5 Requirements 6 Test Methods Appendix A (Normative) Test Layout Appendix B (Normative) Test Phantom
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: TransForyou Co., Ltd. 2008-2040
 
 
Keywords:
YY/T 0740-2009, YY 0740-2009, YYT 0740-2009, YY/T0740-2009, YY/T 0740, YY/T0740, YY0740-2009, YY 0740, YY0740, YYT0740-2009, YYT 0740, YYT0740