DL/T 5253-2010 Design technique and construction regulations for low-voltage distribution network based on the overhead bundled insulated conductors (English Version)
This Standard specifies technical requirements of overhead bundled insulated conductor and design technique and construction regulations for low-voltage distribution network.
This Standard is applicable to design and construction of newly-built and renovated overhead bundled insulated conductor with the rated voltage of 380V/220V.
Foreword I
1 Scope
2 Normative References
3 Terms and Definitions
4 General
5 Meteorological Conditions
6 Code and Model of Bundled Insulated Conductors
7 Technical Requirements of Bundled Insulated Conductors
8 Fittings and Insulators
9 Selection of Bundled Insulated Conductor Section
10 Laying Mode
11 Erection of Bundled Insulated Conductors
12 Safety Distance
13 Lightning Protection and Grounding
Appendix A (Informative) Typical Meteorological Region
Appendix B (Informative) Code and Model of Bundled Insulated Conductors
Appendix C (Informative) Performance Parameters of Conductor
Appendix D (Informative) Mechanical and Physical Performance of Insulation Materials of Bundled Insulated Conductors
Appendix E (Normative) Structural Shape Section of Bundled Insulated Conductors
Appendix F (Normative) Structural Dimension and Technical Parameters of Bundled Insulated Conductors
Appendix G (Normative) Test Rules for Bundled Insulated Conductors
DL/T 5253-2010 Design technique and construction regulations for low-voltage distribution network based on the overhead bundled insulated conductors (English Version)
Standard No.
DL/T 5253-2010
Status
valid
Language
English
File Format
PDF
Word Count
5000 words
Price(USD)
120.0
Implemented on
2011-5-1
Delivery
via email in 1 business day
Detail of DL/T 5253-2010
Standard No.
DL/T 5253-2010
English Name
Design technique and construction regulations for low-voltage distribution network based on the overhead bundled insulated conductors
This Standard specifies technical requirements of overhead bundled insulated conductor and design technique and construction regulations for low-voltage distribution network.
This Standard is applicable to design and construction of newly-built and renovated overhead bundled insulated conductor with the rated voltage of 380V/220V.
Contents of DL/T 5253-2010
Foreword I
1 Scope
2 Normative References
3 Terms and Definitions
4 General
5 Meteorological Conditions
6 Code and Model of Bundled Insulated Conductors
7 Technical Requirements of Bundled Insulated Conductors
8 Fittings and Insulators
9 Selection of Bundled Insulated Conductor Section
10 Laying Mode
11 Erection of Bundled Insulated Conductors
12 Safety Distance
13 Lightning Protection and Grounding
Appendix A (Informative) Typical Meteorological Region
Appendix B (Informative) Code and Model of Bundled Insulated Conductors
Appendix C (Informative) Performance Parameters of Conductor
Appendix D (Informative) Mechanical and Physical Performance of Insulation Materials of Bundled Insulated Conductors
Appendix E (Normative) Structural Shape Section of Bundled Insulated Conductors
Appendix F (Normative) Structural Dimension and Technical Parameters of Bundled Insulated Conductors
Appendix G (Normative) Test Rules for Bundled Insulated Conductors